Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : REKAYASA

Efektivitas Media Filter Pasir Silika dan Arang Ampas Tebu untuk Menurunkan Warna Menggunakan Filtrasi Upflow Farras Fadillah, Raihan; Badriani, Ririn Endah; Fildzah, Cantika Almas
Rekayasa Vol 18, No 1: April 2025
Publisher : Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/rekayasa.v18i1.24483

Abstract

The availability of quality water is crucial for human survival. This study aims to evaluate the efficiency of reducing water colour through the upflow filtration method with variations in silica sand filter media and bagasse charcoal. The research method involves the preparation of research tools and materials, the manufacture of bagasse charcoal, and filter reactors. Experimental stages include raw water preparation and testing, the filtration process, filtration result water collection and testing, and data analysis. The results showed that the colour removal efficiency at 16.72 TCU was highest in reactor 2 (77.07%) and lowest in reactor 3 (45.85%). At 34.28 TCU, the highest efficiency was in reactor 2 (63.24%) and the lowest in reactor 3 (29.09%). The level of 46.08 TCU showed the highest efficiency in reactor 2 (59.33%) and the lowest in reactor 3 (22.53%). Two Ways ANOVA analysis showed that the thickness of bagasse charcoal filter media has a significant effect on colour reduction because the p value is smaller than 0.05. While the thickness of silica sand has no significant effect because the p value is greater than 0.05, The limitation of colour removal is due to the small surface area of silica sand, which cannot absorb a limited amount of dye.
Pengaruh Perbedaan Ketebalan Media Filtrasi Pasir Sungai dan Arang Sekam Padi pada Penurunan Fosfat Air Limbah Calista, Alferina Vania Widya; Badriani, Ririn Endah; Fildzah, Cantika Almas
Rekayasa Vol 17, No 1: April, 2024
Publisher : Universitas Trunojoyo Madura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21107/rekayasa.v17i1.21677

Abstract

WWTP Effluent at Regional Hospital (RSD) dr. Soebandi has not fullfilled quality standard of phosphate which is 3 mg/L. This study aims to determine the efficiency of removal phosphate levels and to determine the effect of variations in the thickness of the filtration media reducing phosphate levels in wastewater from hospital wastewater. Method in this research used a Slow Sand Filter Sandwich system with several variables. The thickness ratio of rice husk charcoal and river sand were (R1) 25:5 cm, (R2) 22,5:7,5 cm, (R3) 20:10 cm, (R4) 17,5:12,5 cm and (R5) 0:0 cm. Variations of time used were 120 and 180 minutes. The lowest and highest efficiency was found in reactor 1 (R1) with 120 minutes for contact time at 0% and reactor 4 (R4) with 180 minutes for contact time by 53%. P-value of rice husk charcoal, river sand and contact time is 0,05 that means it have a significant effect on phosphate concentration reduction. T-test result showed significant differences (p-value 0,05), reactors 1 4, reactors 1 5, reactors 2 4, and reactors 2 5.