Claim Missing Document
Check
Articles

Found 3 Documents
Search

PERANCANGAN ALAT UKUR KADAR pH DAN SUHU AIR BERBASIS ARDUINO UNO Nugroho, Setyo Adi; Aprilia, Septi; Anindyahadi, Fitri; Budi, Naufal Setya
Jurnal Informatika dan Teknik Elektro Terapan Vol 13, No 2 (2025)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v13i2.6398

Abstract

Air merupakan suatu kebutuhan yang tidak bisa dilepaskan dari kegiatan rumah sakit.  Rumah sakit menggunakan air dalam berbagai keperluan seperti persiapan obat, sanitasi, prosedur operasi, keperluan pasien dan kegiatan laboratorium rumah sakit.  Kualitas air untuk kegiatan laboratorium di rumah sakit berbeda dengan kualitas air minum, air untuk keperluan higiene sanitasi, air untuk hemodialisis karena air untuk laboratorium harus memenuhi kemurnian tertentu dan memenuhi maksimum kadar kontaminan ion tertentu agar tidak menjadi katalisator.  Oleh karena itu , pH dan suhu air perlu di ukur agar kontaminan ion dalam air tersebut tidak bereaksi dengan bahan laboratorium yang dapat mengganggu fungsi peralatan laboratorium.  Penelitian ini bertujuan untuk mengetahui cara merancang, sistem kerja dan validasi prototipe alat ukur kadar pH dan suhu air.  Penelitian ini menggunakan metode riset dan pegembangan suatu produk dan menguji keefektifan pada pengukuran kadar pH dan suhu air dengan nilai pH air pada suhu normal yang didapat < 5,0 dikategorikan tidak normal, apabila nilai 5,0 sampai dengan 8,0 dikategorikan normal, apabila > 8,0 dikategorikan tidak normal (Permenkes, 2019).  Berdasarkan pengumpulan data yang dilakukan dengan 10 kali pengujian menggunakan larutan buffer dan sampel air, hasil kesalahan tidak lebih dari 5%. Kesimpulan alat sudah tervalidasi dan suhu dapat mempengaruhi selisih pembacaan pH kemudian untuk pembacaan pH dan suhu alat prototipe bekerja dengan baik.
Design of Sterilizer Calibration With Esp8266 Based on Internet of Things Anindyahadi, Fitri; Nugroho, Setyo Adi; Dewantara, Mahardira; Suyamto, Yuli
Journal of Energy and Electrical Engineering Vol 6, No 2: April 2025
Publisher : Teknik Elektro Universitas Siliwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37058/jeee.v6i2.14927

Abstract

Advancing technology demands reliable monitoring of key indicators such as temperature, a fundamental measure of heat or cold and critical wherever stable setpoints are required. Guided by Industry 4.0 principles, this study develops an Internet-of-Things (IoT) sterilizer calibration tool using an ESP8266 controller for real-time access. The device was built as planned, from component selection and casing design to the accompanying application, and supports continuous temperature observation. The IoT layer simplifies data acquisition and provides reliable, real-time monitoring via the ESP8266. Experimental evaluation shows small deviations from setpoints: at 150 °C the mean error is 0.5 °C, and at 200 °C the mean error is 0.1 °C. Testing followed the Medical Device Calibration Work Method No. 044-18 (2020) for sterilizer performance. All results remain within the permitted tolerance of ±5 °C, indicating that the tool is suitable for use and can assist applications that require stable, precisely monitored temperature conditions.
PERANCANGAN ALAT UKUR KADAR pH DAN SUHU AIR BERBASIS ARDUINO UNO Nugroho, Setyo Adi; Aprilia, Septi; Anindyahadi, Fitri; Budi, Naufal Setya
Jurnal Informatika dan Teknik Elektro Terapan Vol. 13 No. 2 (2025)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v13i2.6398

Abstract

Air merupakan suatu kebutuhan yang tidak bisa dilepaskan dari kegiatan rumah sakit.  Rumah sakit menggunakan air dalam berbagai keperluan seperti persiapan obat, sanitasi, prosedur operasi, keperluan pasien dan kegiatan laboratorium rumah sakit.  Kualitas air untuk kegiatan laboratorium di rumah sakit berbeda dengan kualitas air minum, air untuk keperluan higiene sanitasi, air untuk hemodialisis karena air untuk laboratorium harus memenuhi kemurnian tertentu dan memenuhi maksimum kadar kontaminan ion tertentu agar tidak menjadi katalisator.  Oleh karena itu , pH dan suhu air perlu di ukur agar kontaminan ion dalam air tersebut tidak bereaksi dengan bahan laboratorium yang dapat mengganggu fungsi peralatan laboratorium.  Penelitian ini bertujuan untuk mengetahui cara merancang, sistem kerja dan validasi prototipe alat ukur kadar pH dan suhu air.  Penelitian ini menggunakan metode riset dan pegembangan suatu produk dan menguji keefektifan pada pengukuran kadar pH dan suhu air dengan nilai pH air pada suhu normal yang didapat < 5,0 dikategorikan tidak normal, apabila nilai 5,0 sampai dengan 8,0 dikategorikan normal, apabila > 8,0 dikategorikan tidak normal (Permenkes, 2019).  Berdasarkan pengumpulan data yang dilakukan dengan 10 kali pengujian menggunakan larutan buffer dan sampel air, hasil kesalahan tidak lebih dari 5%. Kesimpulan alat sudah tervalidasi dan suhu dapat mempengaruhi selisih pembacaan pH kemudian untuk pembacaan pH dan suhu alat prototipe bekerja dengan baik.