p-Index From 2020 - 2025
0.408
P-Index
This Author published in this journals
All Journal Kappa Journal
Wayan Balik Sudarsana
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisis Laju Dosis Radiasi Neutron Pada Pekerja Radiasi Menggunakan Surveymeter di Instalasi Radioterapi Ida Bagus Putu Priastana Bawa; Ni Nyoman Ratini; Wayan Balik Sudarsana; Gusti Ngurah Sutapa; I Made Satriya Wibawa; I Gde Antha Kasmawan; Rozi Irhas
Kappa Journal Vol 8 No 3 (2024): Desember
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v8i3.27296

Abstract

The research was carried out at the Radiotherapy Installation at Hospital Prof. Dr. I.G.N.G. Work with the aim of knowing the value of the neutron radiation dose rate at the maximum point after the irradiation is carried out and knowing the value of the neutron radiation dose rate to radiation workers based on the Dose Limit Value permitted by BAPETEN. The research was carried out by measuring the neutron radiation dose rate using a neutron surveymeter at 7 different points with a photon beam of 10 MV energy. At point A, the average value of the neutron radiation dose rate at the maximum point was 6618.87 ± 959.50 µSv/h, at point B it was 1586.99 ± 113.95 µSv/h, at point C it was 1599.90 ± 210.98 µSv/h, at point D it is 1236.83±113.94 µSv/h, at point E it is 297.48±41.79 µSv/h, at point F it is 23.69±3.14 µSv/h h and at point G of 0.54 ± 0.44 µSv/h. Then the value of the equivalent dose rate of neutron radiation at each point is obtained, namely, at point A it is 1.8 µSv/h, at point B 3.2 µSv/h, at point C 3.5 µSv/h, at point D 2 .3 µSv/h, at point E 2.3 µSv/h, at point F 2 µSv/h and at point G 1.9 µSv/h, then the equivalent dose rate value is compared with 1/2 NBD of radiation workers of 5 µSv /h, then the equivalent dose rate value is still below 1/2 of the NBD of radiation workers and the SPO that applies at the Radiotherapy Installation at Hospital Prof. Dr. I.G.N.G. Ngoerah is indeed safe for radiation workers.
Studi Dosis Radiasi Berkas Foton Energi 6 MV dan 10 MV Terhadap Nilai HI dan CI pada Kasus Kanker Serviks Menggunakan Teknik Intensity Modulated Radiation Therapy (IMRT): - Sutapa, Gusti Ngurah; I Wayan Suarya; Wayan Balik Sudarsana; Ida Bagus Made Suryatika; Made Sumadiyasa; I Gusti Agung Widagda
Kappa Journal Vol 8 No 3 (2024): Desember
Publisher : Universitas Hamzanwadi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29408/kpj.v8i3.27385

Abstract

Penelitian ini menganalisis distribusi dosis radiasi foton 6 MV dan 10 MV pada pasien kanker serviks menggunakan teknik Intensity Modulated Radiation Therapy (IMRT). Tujuan penelitian adalah untuk mengevaluasi keseragaman dosis dan kecocokan dosis pada Planning Target Volume (PTV) dengan menggunakan Homogeneity Index (HI) dan Conformity Index (CI). Sampel penelitian terdiri dari 10 pasien kanker serviks yang dirawat di RSUP Prof. I G. N. G. Ngoerah Denpasar. Dosis yang diterima pasien dianalisis menggunakan Dose Volume Histogram (DVH) untuk masing-masing energi foton. Hasil menunjukkan bahwa rata-rata HI untuk energi 6 MV adalah 0,0817 dan untuk 10 MV adalah 0,0803, sementara CI untuk 6 MV dan 10 MV masing-masing adalah 0,9556 dan 0,9701. Nilai HI dan CI yang dihasilkan sesuai dengan standar ICRU Report 83, yang menunjukkan distribusi dosis yang seragam dan efektif pada PTV. Temuan ini mengindikasikan bahwa kedua energi foton dapat memberikan distribusi dosis yang optimal, dan pemilihan energi dapat disesuaikan dengan kebutuhan klinis tanpa mengurangi kualitas terapi.