Claim Missing Document
Check
Articles

Found 2 Documents
Search

Potensi Sistem Absensi Berdasarkan Citra Wajah Sebagai Media Pengabdian Kepada Masyarakat Ath-Thaariq, Bhakti; Fita Lestari, Riska; Mulyadi, Adi
TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat Vol. 2 No. 1 (2022): TEKIBA : Jurnal Teknologi dan Pengabdian Masyarakat
Publisher : Fakultas Teknik, Universitas PGRI Banyuwangi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36526/tekiba.v2i1.1767

Abstract

This paper describes the potential for attendance at Banyuwangi 1 State Vocational High School. The attendance system used is manual and does not optimal. The attendance based on face detector is proposed to determine the performance of employees and students. Face attendance is used to prevent employees from being absent from work and students not attending school. The results of the face detector show that the performance of employees and students can support the learning process in schools.
Perancangan Sistem Recloser Untuk Memantau Konsumsi Daya Listrik Rumah Tangga Menggunakan Modifikasi Arduino Mega Ath-Thaariq, Bhakti; Liswanto, Budi; Diki, Moh
Journal Electric Field Vol. 2 No. 2 (2025): Journal Electric Field
Publisher : CV. Sekawan Siji

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.63440/jef.v2i2.120

Abstract

This paper discusses the design of a recloser system to monitor electricity consumption using a modified Arduino Mega. Excessive use of electrical devices, cables that are too small to handle the current load, or disturbances in the electrical system. As a result, cables or electrical devices can overheat and cause fires or even damage to electrical equipment. To address these problems, the reliability and safety of household electrical installations use a protection system. Protection equipment on a household scale is called (MCB) Miniature Circuit Breaker. The design uses a PZEM-004T sensor, Arduino Mega 2560, relay, and Recloser prototype. The system is designed to detect overload disturbances above the 2 Ampere MCB limit or short circuits in real time and displays power 12.38, 384.8, 376.4 watts, voltage 230.7, 228.2, 228.1V, and current 0,06, 1,29, 1,26A monitoring in the recloser modification system on household-scale electricity consumption. The recloser modification system will work or try to turn ON again when the problem is detected for 3 attempts to enter and will return to normal automatically when the recloser modification system detects that the overload has been resolved by reducing the load or when a short circuit occurs when the Recloser tries to re-enter between 1 and 3 attempts, if it exceeds 3 attempts then the system is permanently OFF and must be reset manually.