EVALUASI SISTEM DISTRIBUSI AIR MINUM PDAM TIRTA PANCUR AJI SPAMIKK PROJAL KELURAHAN BUNUT KABUPATEN SANGGAU Jama, Rofinus; Wahyudi, Reza; Zuandi, Weli
Jurnal Teknologi Infrastruktur Vol 2 No 2 (2022): Jurnal Teknologi Infrastruktur Volume 2 No 2 2022
Publisher : Fakultas Teknik Universitas Panca Bhakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (929.02 KB)

Abstract

Clean water is a source of survival for living things on earth. Bunut Village is one of the villages located in the Kapuas District, Sanggau Regency, West Kalimantan Province, Indonesia located within the Sanggau City area. The background to the lack of equity regarding the distribution of drinking water by PDAM Tirta Pancur Aji at the SPAM IKK Projal service area of Bunut Village is due to the lack of SPAM facilities and infrastructure it affects processing capacity and lacks evaluation of service levels. Therefore, this study aims to evaluate the distribution of drinking water at PDAM Tirta Pancur Aji because every year there is population growth, which affects the level of water demand, the actual conditions regarding the condition of the SPAM IKK Projal have never developed annually, have never evaluated the capacity spam so that the optimization of water distribution to the community has not yet obtained the right strategy for the distribution of drinking water by PDAM Tirta Pancur Aji at SPAM IKK Projal in the Bunut Village Service area. The evaluation of the distribution of PDAM Tirta Pancur Aji water uses population calculations, clean water requirements calculations, and the SPAM IKK Projal strategy to serve the entire Bunut Village community for access to drinking water. Keywords: water distribution, population projection, water demand.
Analisis Intensitas Kebisingan Sebagai Upaya Peningkatan Keselamatan dan Kesehatan Kerja (K3) Yuhana, Yuhana; Zuandi, Weli; Tohari, Sabda Agung Iman
ARMADA : Jurnal Penelitian Multidisiplin Vol. 2 No. 3 (2024): ARMADA : Jurnal Penelitian Multidisplin, Maret 2024
Publisher : LPPM Sekolah Tinggi Ilmu Ekonomi 45 Mataram

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55681/armada.v2i3.1261

Abstract

PT. X merupakan perusahaan yang bergerak pada bidang produksi sawit pekerja di sektor industri pengolahan kelapa sawit yang memiliki risiko tinggi mengalami gangguan pendengaran akibat paparan kebisingan. Jika tenaga kerja tidak menggunakan alat pelindung diri pada saat bekerja serta keterpaparan terhadap kebisingan yang melebihi nilai ambang batas pada kurun waktu yang cukup lama akan menyebabkan gangguan terhadap pendengaran. Tujuan dari penelitian ini untuk mengetahui tingkat kebisingan dan luas paparan serta ganguan pendengaran terhadap pekerja. Penelitian ini menggunakan metode survei analitik yang menggunakan pendekatan Cross Sectional, Pembuatan peta menggunakan perangkat lunak ArcGIS. Hasil dari penelitan tingkat kebisingan sebesar 52.47-92.07 dBA. Intensitas kebisingan terendah berada pada titik 1 (area kantor) dipengukuran L1 sebesar 52.47 dBA, sedangkan intensitas kebisingan tertinggi yaitu berada pada pada titik 3 (Boiler) dipengukuran L3 sebesar 92,07 dBA. Waktu paparan terlama yang diperbolehkan berada di titik 1 dengan nilai sebesar 16,000 Jam, sedangkan lama paparan tersingkat dipengukuran L3 pada titik 3 dengan nilai sebesar 1.56 jam. Peta sebaran intensitas kebisingan, warna hijau menunjukan paparan antara 60-68 dBA seluas 600 m2, warna kuning menunjukan paparan antara 68-76 dBA seluas 600 m2, warna orange menunjukan paparan antara 76-84 dBA seluas 900 m2 dan warna merah menunjukan antara 84-92 dBA dengan luas paparan 1.900 m2.
Penentuan Status Mutu Air Berdasarkan Indeks Pencemaran Pada Daerah Irigasi Rawa Teluk Bayur Zuandi, Weli; Normagiat, Sigit
Al-Ard: Jurnal Teknik Lingkungan Vol. 9 No. 2 (2024): March
Publisher : Department of Environmental engineering, Faculty of Science and Technology, Islamic State University Sunan Ampel Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29080/alard.v9i2.1837

Abstract

Bayur Bay Swamp Irrigation Area (DIR) has a land area of ​​(70.88 km2), so an irrigation system with sufficient water discharge and appropriate quality of irrigation water is needed.The purpose of this study was to determine the quality and status of DIR Teluk Bayur irrigation water. Based on the regulations in force, the use of water in the DIR is sufficient for class IV quality status, but the problem that occurs in the Teluk Bayur DIR is that the water in the DIR network is used by the community to meet the needs of their daily activities. Where the use of water for daily needs is included in class II water quality. Therefore, it is necessary to measure water quality using the Water Pollution Index (IPA) method to determine the status of water pollution levels in class II water quality based on RI Government Regulation No. 22 Year 2021. From the test results, it was found that the Total Phosphate Parameter was below the quality standard so that based on the calculation results using the Water Pollution Index method, samples SA3 and SA4 were heavily polluted with pollution index values ​​of 12.43 and 12.80, where the maximum Ci/Lij values ​​were respectively respectively are 17.50 and 18.04 while the status of SA1 pollution index value is 1.89 lightly polluted and SA2 pollution index is 4.40 moderately polluted. So that from all water quality tests it can be said that the quality of irrigation water in Teluk Bayur DIR still does not meet all of the quality standard parameters that have been set. 89 are lightly polluted and the SA2 pollution index is 4.40 moderately polluted. So that from all water quality tests it can be said that the quality of irrigation water in Teluk Bayur DIR still does not meet all of the quality standard parameters that have been set. 89 are lightly polluted and the SA2 pollution index is 4.40 moderately polluted. So that from all water quality tests it can be said that the quality of irrigation water in Teluk Bayur DIR still does not meet all of the quality standard parameters that have been set.