Indonesian Journal of Chemistry
Vol 23, No 2 (2023)

The Stability Study of Electrochemical Aptasensor to Detect SARS-CoV-2 Spike Protein and Its Application for Clinical Samples of Nasopharyngeal Swab

Arum Kurnia Sari (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Raya Bandung-Sumedang Km. 21, Jatinangor, Sumedang 45363, Indonesia)
Ghina Nur Fadhilah (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Raya Bandung-Sumedang Km. 21, Jatinangor, Sumedang 45363, Indonesia)
Irkham Irkham (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Raya Bandung-Sumedang Km. 21, Jatinangor, Sumedang 45363, Indonesia)
Muhammad Yusuf (Molecular Biotechnology and Bioinformatics Research Center, Universitas Padjadjaran, Jl. Singaperbangsa No. 2, Bandung 40132, Indonesia)
Shabarni Gaffar (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Raya Bandung-Sumedang Km. 21, Jatinangor, Sumedang 45363, Indonesia
Molecular Biotechnology and Bioinformatics Research Center, Universitas Padjadjara)

Yeni Wahyuni Hartati (Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran, Jl. Raya Bandung-Sumedang Km. 21, Jatinangor, Sumedang 45363, Indonesia
Molecular Biotechnology and Bioinformatics Research Center, Universitas Padjadjara)



Article Info

Publish Date
03 Mar 2023

Abstract

The stability characteristics associated with the shelf life of a biosensor are rarely investigated, however, they are important factors for real applications. Stability is the variation in the detection signal over a long period of storage. This study aims to determine the effect of storage time on the stability of SARS-CoV-2 receptor binding domain (RBD) spike protein aptamers related to shelf life and the performance of an electrochemical aptasensor on clinical samples. The research method includes a stability study conducted using the accelerated stability method based on the Arrhenius equation at three variations of temperature and storage time. The electrochemical aptasensor's performance was evaluated on clinical samples of 32 nasopharyngeal swabs at biosafety level 3 and its potential on clinical saliva samples. The results indicated that the developed electrochemical aptasensor was stable for ± 15 days with a shelf life of 18, 17 and 16 days, respectively, at 25, 40 and 50 °C. This electrochemical aptasensor has the potential to be a Point of Care (POC) device for the clinical detection of SARS-CoV-2 because it can be tested on clinical samples of nasopharyngeal swabs and the results show its potential application to detect in clinical saliva samples.

Copyrights © 2023






Journal Info

Abbrev

ijc

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Chemistry

Description

Indonesian Journal of Chemistry is an International, peer-reviewed, open access journal that publishes original research articles, review articles, as well as short communication in all areas of chemistry including applied chemistry. The journal is accredited by The Ministry of Research, Technology ...