Comparative Seismic Performance of Flat Slab-Drop Panel and Conventional Slab Systems for Hospital Buildings

Putu Didik Sulistiana (Department of Professional Engineer Program, Faculty of Engineering and Planning, Warmadewa University, Bali, 80239)
I Putu Pranayoga Aditya (Department of Civil Engineering, Faculty of Engineering and Planning, Warmadewa University, Bali, 80239)
I Gusti Agung Putu Eryani (Department of Civil Engineering, Faculty of Engineering and Planning, Warmadewa University, Bali, 80239)



Article Info

Publish Date
18 Jul 2026

Abstract

Hospitals are classified as essential facilities and therefore require adequate seismic performance to maintain structural safety during earthquake events. This study compares the seismic performance of a conventional slab system and a flat slab-drop panel (FSDP) system in a four-story reinforced concrete hospital building using the Response Spectrum Analysis (RSA) method. Two three-dimensional structural models were developed in ETABS v21.2 with identical geometry, material properties, loading conditions, and boundary conditions. The only variable considered was the floor system configuration. Structural responses, including structural weight, fundamental period, inter-story drift, slab deflection, base shear, and column reinforcement demand, were evaluated in accordance with SNI 1726:2019 and SNI 2847:2019. The results indicate that the FSDP system increased the total structural weight by 6.54%, the fundamental period by 30.2% and 18.2% in the X- and Y-directions, respectively, and the base shear by 42.29% and 26.85%. In addition, the FSDP system produced larger inter-story drift, slab deflection, and column design demand than the conventional slab system. Nevertheless, all evaluated structural responses satisfied the design requirements specified in the applicable Indonesian standards. Overall, the conventional slab system was found to be more structurally efficient, exhibiting lower inter-story drift, slab deflection, base shear, and column reinforcement demand than the FSDP system, while both structural systems satisfied the seismic design requirements specified in SNI 1726:2019 and SNI 2847:2019. The FSDP system, however, offers greater architectural flexibility and construction efficiency.

Copyrights © 2026






Journal Info

Abbrev

jice

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Engineering Environmental Science Materials Science & Nanotechnology Transportation

Description

Journal of Infrastructure and Civil Engineering (JICE) focuses on civil engineering expertise. Detailed scopes of articles accepted for submission to JICE are: Material and structure Transportation Geotechnical Water resource management Project management Disaster ...