Foamed concrete is attractive for earthquake-prone regions because of its low self-weight, but its low tensile capacity and brittle failure limit its structural use. This study examines how nylon fibre (25 mm long, 0.35 mm in diameter) modifies the compressive, splitting tensile, and flexural strength of foamed concrete. A 3 × 3 factorial programme combined three specific gravities (SG 1.2, 1.4, and 1.6) with three fibre contents (0.5%, 1.0%, and 1.5% by mass) at a water–cement ratio of 0.4, and 81 specimens were tested at 28 days. Results were compared with fibre-free foamed concrete of the same SG and analysed using two-way analysis of variance and multiple linear and polynomial regression. Nylon fibre increased compressive strength by 38–153%, splitting tensile strength by 42–136%, and apparent flexural strength by 210–694%, with the highest mean values of 24.7, 3.15, and 7.27 MPa, respectively. Fibre content alone did not significantly affect compressive strength (F = 3.35 < 3.55) but significantly affected tensile and flexural strength, and its interaction with SG was significant for all three properties. Polynomial models (R² = 0.74–0.84) described the data better than linear models (R² = 0.64–0.73). Flexural strength was nearly independent of compressive strength (r = 0.01), and nylon outperformed ijuk and coir fibres in flexure. The findings support nylon-fibre foamed concrete as a promising lightweight material, pending structural-element and durability tests.
Copyrights © 2026