Single-phase grid-tied inverters (GTIs) are widely used in residential and small-scale distributed generation, where conventional control relies on multi-loop PI regulators, PWM modulators, and phase-locked loop (PLL)/second-order generalized integrator (SOGI) synchronization, which increases design and tuning complexity. This study aims to evaluate a simple finite-control-set model predictive control (FCS-MPC) voltage-tracking strategy for a single-phase full-bridge GTI that requires neither a PLL/SOGI nor a PWM modulator. The control action is selected from {+Vdc, 0, −Vdc} using a two-step prediction horizon with a sampling time of Ts = 1 μs, and the scheme is evaluated in MATLAB/Simulink. The evaluation covers the voltage quality at the point of common coupling (PCC), the current sharing between the grid and the inverter during interconnection, the current phase, and Kirchhoff’s current law (KCL) consistency in the time and phasor domains. In steady state, the PCC voltage follows the grid voltage with an RMS tracking error of 0.17 V, and the harmonic distortion of the PCC voltage and inverter current is below 0.002%. After interconnection (ton = 0.06 s), the grid current decreases from 10.98 A to 0.35 A, while the inverter supplies 10.67 A practically in phase with the PCC voltage (power factor ≈ 1), covering about 97% of the 2.42 kW load. The KCL check confirms a consistent current balance at the PCC. These results show that, under voltage tracking, the current sharing between the grid and the inverter is determined by the voltage reference and its measurement point rather than by an explicit power command. The limitations are the absence of explicit power-sharing control and the high average switching frequency (≈ 197 kHz). Future work will address reference shaping for power-sharing control, current-tracking MPC with switching penalties, and experimental validation.
Copyrights © 2026