cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
jacee@unissula.ac.id
Editorial Address
Jl Raya Kaligawe KM 4 Semarang
Location
Kota semarang,
Jawa tengah
INDONESIA
Journal of Advanced Civil and Environmental Engineering
ISSN : 25993356     EISSN : -     DOI : http://dx.doi.org/10.30659/jacee
Core Subject : Social, Engineering,
Journal of Advanced Civil & Environmental Engineering invites and welcomes the submission of advanced research and review papers, innovations and developed selected conference papers that have never been previously publicized. This journal provides publications and a forum to the academics, scholars and advanced level students for exchanging significant information and productive ideas associated with all these disciplines. The relevant topics of the latest progressive findings or developments will be taken seriously into consideration, the topics covered by the journals include: Materials Structure and Structural Analysis Geotechnic Water resources/hydro Construction management Transportation Highway engineering Environmental science and engineering
Articles 114 Documents
Cost Modeling of Road Maintenance Using the Cost Significant Method in Disaster Prone Areas of Solok Regency Lucky Ramanur Sukandar; P Purnawan; Elsa Eka Putri
JACEE (Journal of Advanced Civil and Environmental Engineering) Vol. 9 No. 1 (2026): April
Publisher : Engineering Faculty, Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jacee.9.1.29-42

Abstract

This study aims to develop cost model for a periodic road maintenance project. The background is the lack of a simple and accurate calculation method to estimate the cost of the work. The model was developed using the Cost Significant Model (CSM) method and multiple linear regression, using historical data of periodic road maintenance work contracts at the Public Works and Spatial Planning Agency (DPUPR) of Solok Regency for the period 2018–2023. The analysis results show that the most significant work on the project cost is K-175 shoulder concrete, Class A Aggregate Foundation Layer (LPA), and Asphalt Concrete-Wearing Course (AC-WC). The resulting cost estimation model is Y = 4,531.24 + 1.19 X₁₄ + 1.35 X₁₅ + 1.43 X₁₉, with Y as the project cost per m², X₁₄ the price of K-175 shoulder concrete per m², X₁₅ the price of Class A LPA per m², and X₁₉ the price of AC-WC per m². This model has an average CMF value of 1.004 and a model deviation of 2.965%, much more accurate than the estimation method currently used by the Highways Division of the DPUPR of Solok Regency which has an average deviation of 29.951%. Thus, the developed CSM model is proven to be more accurate and suitable for estimating the costs of periodic road maintenance projects in Solok Regency.
Haunch Beams Behavior And Performance In High-Rise Buildings With Spectrum And Pushover Response Gali Pribadi; Rinda Karlinasari
JACEE (Journal of Advanced Civil and Environmental Engineering) Vol. 9 No. 1 (2026): April
Publisher : Engineering Faculty, Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jacee.9.1.43-54

Abstract

Indonesia is located in an active tectonic zone with high seismic potential, so that high-rise building structures are very vulnerable to earthquake loads. One alternative to improve structural performance is the use of haunch beams, a non-prismatic beam model with varying stiffness in length. This study examines the effectiveness of haunch beams in improving the seismic performance of the SRPMK system, a 60 m high building without shear walls and with varying column dimensions along the building height. Prismatic beams (50/35) and haunch beams (100/35) with varying lengths of 1/5L, 1/4L, and 1/3L were used in the beam-column connection. The analysis was carried out using the response spectrum method and the nonlinear static pushover method. The results of the pushover analysis study, with the 1/3L haunch beam configuration, provided better structural performance in controlling drift and displacement, especially in high-rise buildings with columns that taper upwards. The nonlinear static procedure method (pushover) showed that the 1/3L haunch beam variant showed the most effective performance. Pushover X, displacement 0.259 m, base shear 16583 kN, drift 0.81% ≤ 1%, category IO, pushover Y, displacement 0.448 m, base shear 24498 kN, drift 1.33% ≤ 2%, limit category IO-LS. Smaller drift valuesindicate increased stiffness of the frame system. B-Haunch 1/3 L provides better structural performance in controlling drift and displacement, especially in tall buildings with columns that taper upwards. Smaller drift valuesindicate increased stiffness of the frame system. The addition of shear walls later will increase stiffness.
Analysis of the Addition Of Binding Wire and Ethylene Vinyl Acetate on the Stability And Flow Performance of Asphalt Treated Permeable Superpavement for Coastal Road Pavement Ferdiano Yogi Pradana Yogi Pradana; Rachmat Mudiyono
JACEE (Journal of Advanced Civil and Environmental Engineering) Vol. 9 No. 1 (2026): April
Publisher : Engineering Faculty, Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jacee.9.1.70-83

Abstract

The Pantura national road in Indonesia, frequently experiences problems with waterlogging, mostly caused by extreme weather conditions such as continuous rain, resulting in flooding and rising sea levels that inundate the road construction. To address these issues, an unconventional asphalt pavement design is needed. This study aims to create a Superpave (Superior Performing Asphalt Pavements) graded asphalt composition with EVA (Ethylene Vinyl Acetate) and Binding Wire additives that are expected to meet Marshall and Permeability criteria. The method used in this study is an experimental study. Test specimens were prepared and subjected to Marshall and Permeability tests. The specimens were prepared using EVA (Ethylene Vinyl Acetate) additives of 0%, 1%, 3%, and 5% and Binding Wire at 0%, 2%, 4%, 6%, and 8%. In the research results, along with the increasing percentage of EVA and Binding Wire, the highest stability value was obtained in the E0B8 Cement material variation of 2578.99 Kg. The highest Flow value was in E5B5 Cement of 3.90 mm. The highest Marshall Quotient value was in E0B8 Lime of 701.55%. The highest Void In Mineral Aggregate (VMA) and Void Filled with Asphalt (VFA) values were obtained in the E0B0 Lime material variation of 20.51% and 84.70%, respectively. The highest Void in The Mix (VIM) value was obtained in E5B8 Cement of 4.63%. While the highest Dry Density Permeability was in E5B8 of 0.92 gr/cm2 Cement and the highest Permeability Coefficient was in E0B4 of 1.64528E-05 gr/cm Limestone.
Technical Evaluation of Bridge Pier Structural Strengthening to Meet Bridge Class Standards Due to Changes in Structural and Traffic Loads Didik Setyo Purwantoro; Muhammad Nur Fajar; Herlina Arifin; Alfina Maysyurah
JACEE (Journal of Advanced Civil and Environmental Engineering) Vol. 9 No. 1 (2026): April
Publisher : Engineering Faculty, Universitas Islam Sultan Agung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30659/jacee.9.1.55-69

Abstract

Upgrading bridge specifications from Class B to Class A necessitates a significant increase in structural load capacity. This study evaluates pier P-2, which exhibited capacity discrepancies under new loading standards. The analysis focuses on the stability of existing pile foundations and reinforcement design through modifications to pile-cap dimensions and the addition of piles. The methodology integrates AllPile software with analytical validation via the Chin and Mazurkiewicz methods, alongside axial load tests following ASTM D1143. Structural verification was conducted using the AASHTO LRFD approach to ensure precise load and resistance factors. Static load test results showed a single pile axial capacity of 1,814.23 kN (SF=2). Analysis of the initial 7x3 pile group configuration (21 piles) yielded a total group bearing capacity (Qtg) of 11,995.64 kN. This value is lower than the design axial load (V = 21,228.88 kN), rendering the foundation "unsafe." To achieve stability, reinforcement piles were designed. Utilizing a new static capacity (Qstatic) of 2,875.85 kN (SF=2), the group capacity increased to 12,012.24 kN. With additional reinforcement valued at 16,040.40 kN, the final total capacity (Qtg) reached 28,052.60 kN. This result satisfies safety requirements (Qtg > Vtotal = 23,152.90 kN), confirming the system as "safe." Reinforcement pile depth is set between 38 m to 42 m based on N-SPT values, referencing the calendering results at 34 m.

Page 12 of 12 | Total Record : 114