cover
Contact Name
Paska Hasugian
Contact Email
infokum@seaninstitute.org
Phone
+6281264451404
Journal Mail Official
infokum@seaninstitute.org
Editorial Address
Komplek New Pratama ASri Blok C, No.2, Deliserdang, Sumatera Utara, Indonesia
Location
Unknown,
Unknown
INDONESIA
INFOKUM
Published by SEAN INSTITUTE
ISSN : 23029706     EISSN : 27224635     DOI : -
Core Subject : Science,
The INFOKUM a scientific journal of Decision support sistem , expert system and artificial inteligens which includes scholarly writings on pure research and applied research in the field of information systems and information technology as well as a review-general review of the development of the theory, methods, and related applied sciences. Software Engineering. Image Processing Datamining Artificial Neural Networks
Articles 905 Documents
Sales Level Analysis Based on Price and Transaction Volume Using the Naïve Bayes Algorithm at Onten BSD Nasria Ariska Putri; Belsana Butar Butar; Kartika Mariskhana
INFOKUM Vol. 14 No. 04 (2026): Infokum 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i94.3146

Abstract

Sales performance is an important aspect to consider in inventory management and business decision-making. This study aims to examine the relationship between price categories and sales levels and to implement the Naive Bayes algorithm for classifying product sales growth at Onten BSD. The study utilized 414 sales records, which were processed through several stages, including data cleaning, data transformation, and label encoding. The dataset was subsequently divided into training and testing sets using an 80:20 ratio through the train-test split method. Model performance was evaluated using a Confusion Matrix, Accuracy, Precision, Recall, F1-Score, and Classification Report. The results indicate that products in the Cheap category had the highest average sales volume, reaching 93.41 units. The implementation of the Naive Bayes algorithm achieved an Accuracy of 85.54%, Precision of 88.82%, Recall of 85.54%, and F1-Score of 85.26%. These findings demonstrate that the Naive Bayes algorithm can effectively classify product sales Growth and provide useful insights into sales conditions. Therefore, its application can support Onten BSD in managing products more appropriately and making more informed business decisions.
IoT-Enabled Thermal Comfort Monitoring Using THI with XGBoost-Based Short-Term Forecasting Muhammad Afif; Marzuki Sinambela; Dibyo Susanto; Muchamad Rizqy Nugraha; Achmad Fahruddin Rais
INFOKUM Vol. 14 No. 04 (2026): Infokum 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i03.3149

Abstract

Rapid urban expansion and climate anomalies have intensified localized heat stress, demanding precise microclimatic tracking and proactive public health measures. Conventional observation networks often lack the spatial density and real-time predictive capabilities required for timely intervention. To address this challenge, this study presents the design, field implementation, metrological validation, and predictive evaluation of an Internet of Things (IoT) monitoring system integrated with eXtreme Gradient Boosting (XGBoost) for short-term Temperature-Humidity Index (THI) forecasting. The physical architecture employs a calibrated DHT22 sensor enclosed within a protective Stevenson screen and connected to an ESP32 processing node, transmitting continuous microclimatic metrics wirelessly to a Firebase cloud database. Sensor calibration against primary national standards confirmed high operational accuracy, yielding expanded uncertainties within -0.14°C to +0.18°C for ambient temperature and -1.21% to +1.76% for relative humidity, fully satisfying World Meteorological Organization (WMO) operational tolerances. Telemetry network stability evaluated under Telecommunications and Internet Protocol Harmonization Over Network (TIPHON) benchmarks demonstrated excellent performance, characterized by a low latency of 88.29 ms, packet jitter of 21.85 ms, and a high data throughput of 80293.43 bps. Furthermore, the cloud-integrated XGBoost regression model achieved exceptional accuracy in forecasting short-term thermal trends, yielding a Mean Absolute Error (MAE) of 0.1580, Root Mean Square Error (RMSE) of 0.2113, Mean Absolute Percentage Error (MAPE) of 0.5525%, and a Coefficient of Determination (R²) of 0.9681 for THI predictions. By combining low-cost, metrologically traceable IoT hardware with high-precision machine learning forecasting, this system provides a reliable and scalable framework to transition urban thermal risk management from reactive tracking to proactive climate adaptation.
Analysis Feasibility Study of Smart Chicken Feeding Protection and Wiring System Patar Simanungkalit; Solly Aryza; Siti Anisah
INFOKUM Vol. 14 No. 05 (2026): Infokum, 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i05.3150

Abstract

The development of Internet of Things (IoT) technology has encouraged the implementation of automation systems in the livestock sector, particularly to improve the efficiency of chicken feeding processes. This study aims to analyze the feasibility of the protection system and wiring design in a smart chicken feeder to ensure safety, reliability, and operational efficiency. The system is designed using a microcontroller, sensors, actuators, and an electrical network equipped with protection components such as fuses, miniature circuit breakers (MCB), and grounding systems to prevent overcurrent, short circuits, and potential device damage. The research method includes wiring diagram design, power requirements analysis, protection system evaluation, and performance testing of the device under operational conditions. The analysis results show that the implementation of an appropriate protection system can improve device safety, reduce the risk of electronic component damage, and ensure continuous automatic and scheduled feeding. The feasibility study concludes that the designed protection and wiring system meets technical, economic, and operational aspects, making it suitable for implementation as an appropriate technology solution to support productivity in automated poultry farming.
Analysis of Oxygen Sensor Data Stream and Short Term Fuel Trim (STFT)for Detecting Injection System Fault Symptoms in Four-Wheeled Vehicles Firza Ardana; Hamdani Hamdani; Ahmad Dani
INFOKUM Vol. 14 No. 05 (2026): Infokum, 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i05.3151

Abstract

The modern EFI system has become the backbone of engine performance control, yet diagnosing faults within it remains a challenge when no Diagnostic Trouble Code (DTC) has been triggered. This study investigates the diagnostic potential of oxygen (O₂) sensor waveforms and Short Term Fuel Trim (STFT) data streams acquired via the OBD-II protocol on a Toyota Innova 1TR-FE. Six experimental conditions were tested—normal idle, normal at approximately 2,500 rpm, injector fault at idle, injector fault at 2,500 rpm, vacuum leak at idle, and vacuum leak at 2,500 rpm—using Toyota Global TechStream (GTS+) as the data acquisition interface. The analysis employed a residual generation approach combined with rule-based decision-level data fusion to distinguish between the three operating states. Results reveal that vacuum leaks produce a distinctive STFT elevation of up to +19.70%, while injector faults cause O₂ sensor voltage to fall to extremely low levels (0.011–0.042 V) with a complete cessation of switching activity (0 Hz). Integrating both parameters through decision-level data fusion enabled unambiguous differentiation among normal, vacuum leak, and injector fault conditions across all tested scenarios. The proposed method achieved a classification accuracy of 100%, surpassing the minimum target of 85%. These findings suggest that combined O₂ sensor and STFT data streams offer a practical and effective foundation for early-stage OBD-II-based fault diagnosis in EFI vehicles.
Analysis of PJU Planning for Street Lighting Resources in Suka Maju Indah Village Muhammad Tegar; Dino Erivianto; Zuraidah Tharo
INFOKUM Vol. 14 No. 05 (2026): Infokum, 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i05.3152

Abstract

Street Lighting (Public Street Lighting/PJU) planning plays a vital role in improving road safety, security, and comfort, particularly in developing residential areas. This study aims to analyze the street lighting requirements and develop an appropriate Public Street Lighting (PJU) plan for Suka Maju Indah Village to achieve effective, energy-efficient, and standard-compliant illumination. The research employed a field survey to evaluate the existing road lighting conditions, measure road dimensions, identify available lighting facilities, and calculate lighting requirements based on SNI 7391:2008 and the recommendations of the Commission Internationale de l'Eclairage (CIE). The analysis focused on key parameters, including illuminance level, pole spacing, mounting height, lamp power, and electrical energy consumption. The results indicate that the existing street lighting system in Suka Maju Indah Village does not fully satisfy the recommended lighting standards due to uneven light distribution and insufficient illuminance on several road sections. The proposed design, utilizing high-efficiency LED luminaires with optimized pole spacing and appropriate mounting heights, significantly improves lighting performance while reducing energy consumption compared to conventional lighting systems. The proposed Public Street Lighting (PJU) system is expected to enhance traffic safety, minimize the risk of nighttime accidents and criminal activities, and reduce long-term operational costs through improved energy efficiency. The findings of this study provide practical guidance for local governments and residential developers in designing sustainable and technically compliant street lighting systems.
Analysis of Compressor Motor Starting Current in a Block Ice Factory with Star-Delta Connection Using ETAP Software Deo Talup Marjuki Purba; Muhammad Erpandi Dalimunthe; Zuraidah Tharo
INFOKUM Vol. 14 No. 05 (2026): Infokum, 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i05.3153

Abstract

The abstract should be written as a the three-phase induction motor in a block ice factory compressor has a high starting current, which can cause voltage drops and disruptions in the electrical power system. This study aims to analyze the starting current of the compressor motor using the Star-Delta method with the aid of ETAP software. The research method involved collecting technical data on the motor, transformer, and electrical distribution system, followed by conducting Motor Acceleration Analysis simulations in ETAP. The results show that the Star-Delta method is able to reduce the starting current compared to the Direct On Line (DOL) method, resulting in more stable system voltage and reduced disruptions in the distribution network. Furthermore, switching from a Star to Delta connection results in momentary current surges that remain within safe limits according to electrical power system standards. This study demonstrates the effectiveness of the Star-Delta method in improving the reliability of the electrical system in a block ice factory.
Hot Spot Analysis on Pt PLN (PERSERO) UPT Padang Substation Equipment Using Thermovision as an Effort to Improve System Reliability Dhery Sukma Ibdaya; Hamdani Hamdani; Siti Anisah
INFOKUM Vol. 14 No. 05 (2026): Infokum, 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i05.3154

Abstract

Power transformers are one of the main equipment in substations that play an important role in maintaining the continuity of electric power distribution. One of the problems that often occur in substation equipment is the emergence of hot spots due to increased contact resistance on electrical connections. If not immediately addressed, this condition can cause a decrease in equipment reliability to power system disruption. This study aims to analyze the hotspot condition on the Primary Bushing Clamp of Power Transformer #2 (TD#2) in Lubuk Alung Substation using the thermovision method and evaluate the effect of transformer loading on the increase in hotspot temperature. The research method is carried out through thermovision inspection, equipment temperature measurement, transformer loading analysis, and temperature evaluation before and after repair actions. The measurement results show that under normal operating conditions a hotspot is detected on the Primary Bushing Clamp of TD#2 phase T with a temperature of 60.5°C, while the reference temperature is 35.2°C so that a temperature difference of 25.3°C is obtained. When Power Transformer #1 (TD#1) was not operating, the load current of TD#2 increased from 282 A to 461 A or by 63.48%, which caused the hotspot temperature to increase to 97.9°C. After load reduction through system maneuvers and corrective actions at the connection point, the hotspot temperature was successfully reduced to 23.6°C or decreased by 74.3°C (75.89%). The results showed that increasing transformer loading affected the temperature increase at the hotspot point. In addition, thermovision was proven effective as a predictive maintenance method for early detection of abnormal conditions, evaluating the severity of hotspots, and supporting maintenance decision making to improve the reliability of the electric power system at the substation.
ANALYSIS OF GEOGRAPHIC INFORMATION DESIGN FOR HOTEL LOCATIONS IN LAU GUMBA VILLAGE BASED ON ANDROID Muhammad Amin; Chairul Rizal; Adityia Rama Sanjaya
INFOKUM Vol. 10 No. 02 (2022): Juni, Data Mining, Image Processing, and artificial intelligence
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v10i02.3160

Abstract

Lau Gumba Village is a village located in Brastagi District, Karo Regency, North Sumatra Province which is quite well known because it has quite interesting tourist objects to visit. The information system that presents information on tourist attractions in the village only displays pictures and names which are presented in the form of maps, newspaper and web advertising media that do not provide direct instructions to the destination tourist location. The problem obtained from the media information for tourists is that they do not get direct instructions on the location of the tourist attraction geographical position. This requires technology that can present tourist attraction information, namely Geographic Information Systems (GIS). So that tourists who want to travel to Lau Gumba Village but still don't know the location or place of an interesting tourist attraction to visit can be known by tourists who will visit. To overcome this problem the author uses an approach to a digital mapping model in the form of a GIS (Geographical Information System) based on an Android mobile using Google Maps as a digital map. The method used in this research is using UML (Unifed Modeling Language), PHP program, java and MySQL database as data storage. The Geographic Information System (GIS) for natural tourism objects has two programs, namely an admin program to manage web-based tourism data and a user program to display android-based tourist objects. This geographic information system aims to provide convenience and speed to the public in obtaining information about Natural Tourism Objects in Lau Gumba Village
Feasibility Analysis of 150 Kv Circuit Breaker (PMT) for Padang Luar 2 Conductor Bay at Maninjau Substation Fajar Irawan; Siti Anisah; Pristisal Wibowo
INFOKUM Vol. 14 No. 05 (2026): Infokum, 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i05.3161

Abstract

The high-voltage electrical energy distribution system plays a crucial role in delivering electrical energy from generators to distribution or customers. This high-voltage distribution process starts from 30 kV to 150 kV. The transmission network connecting the Maninjau Substation and Padang Luar Substation uses bare conductors in its distribution. The use of bare conductors causes this transmission network to experience external disturbances. A reliable protection system is essential, so that if a disturbance occurs, it can be quickly detected and quickly isolated or removed from the disturbance current. The role of the protection system in providing signals or command input to the PMT greatly influences the PMT's performance. The PMT's role is also very vital, because the PMT must be able to operate when a disturbance occurs, whether under load or not. Therefore, PMT maintenance needs to be carried out periodically to prevent PMT failures. One of the causes of PMT failures is a low SF6 value, a high simultaneity value, a high contact resistance value, and others. High contact resistance in PMTs also significantly affects network losses. This research was conducted to examine how much the contact resistance value influences losses in the network and PMT performance, how much influence the PMT simultaneity has in isolating the presence of disturbances.
Analysis of the Effect of Cable Temperature and Electric Current on Cable Bending Characteristics Esther Febrina Simanjuntak; Dino Erivianto; Zuraidah Tharo
INFOKUM Vol. 14 No. 05 (2026): Infokum, 2026
Publisher : Sean Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58471/infokum.v14i05.3162

Abstract

Electrical cables are one of the main components in electrical power distribution systems, functioning as a medium for conducting electric current. In their application, cables often experience bending conditions due to improper installation that does not comply with standards, which can affect their thermal and mechanical characteristics. This study aims to analyze the effect of cable temperature and electric current magnitude on the bending characteristics of NYM 2×1.5 mm² and NYMHY 2×2.5 mm² electrical cables. The research method used was an experimental method with current variations of 0.9 A, 1.1 A, 1.4 A, and 5 A, as well as bending angle variations of 0°, 15°, 60°, and 90°. Measurements were carried out using a digital thermometer and clamp meter over a certain time interval. The results showed that an increase in electric current caused a significant rise in cable temperature. Bending at smaller angles produced higher heat concentration compared to bending at larger angles. The highest temperature was obtained at a current of 5 A with a bending angle of 0°, reaching 25.6°C. This temperature increase affected the flexibility and insulation durability of the cable. Based on the research results, it can be concluded that the combination of high current and small bending angles accelerates cable quality degradation and increases the risk of insulation damage.

Filter by Year

2018 2026


Filter By Issues
All Issue Vol. 14 No. 05 (2026): Infokum, 2026 Vol. 14 No. 04 (2026): Infokum 2026 Vol. 14 No. 03 (2026): Infokum, May - June 2026 Vol. 14 No. 02 (2026): Infokum, March-April 2026 Vol. 14 No. 01 (2026): Infokum, January - February 2026 Vol. 13 No. 06 (2025): Infokum Vol. 13 No. 05 (2025): Infokum Vol. 13 No. 04 (2025): Infokum Vol. 13 No. 03 (2025): Infokum Vol. 13 No. 02 (2025): Infokum Vol. 13 No. 01 (2025): Infokum Vol. 12 No. 04 (2024): Engineering, Computer and Communication, November 2024 Vol. 12 No. 01 (2024): Engineering, Computer and Communication, Edition January 2024 Vol. 11 No. 05 (2023): Engineering, Computer and Communication Vol. 11 No. 04 (2023): Agustus : Engineering, Computer and Communication Vol. 11 No. 03 (2023): Juni : Engineering, Computer and Communication Vol. 11 No. 02 (2023): April, Engineering, Computer and Communication Vol. 10 No. 03 (2022): August, Data Mining, Image Processing, and artificial intelligence Vol. 10 No. 02 (2022): Juni, Data Mining, Image Processing, and artificial intelligence Vol. 10 No. 5 (2022): December, Computer and Communication Vol. 10 No. 4 (2022): October, computer, information and engineering Vol. 10 No. 1 (2021): Desember, Data Mining, Image Processing, and artificial intelligence Vol. 9 No. 2, June (2021): Data Mining, Image Processing and artificial intelligence Vol. 9 No. 1,Desember (2020): Data Mining, Image Processing,artificial intelligence, networking Vol. 8 No. 2, Juni (2020): Data Mining, Image Processing and artificial intelligence Vol. 8 No. 1, Desembe (2019): Data Mining,Image Processing and artificial intelligence Vol. 7 No. 2, Juni (2019): Data Mining And Image Processing Vol. 6 No. 02 (2018): Infokum, June 2018 Vol. 7 No. 1, Desembe (2018): Data Mining And Image Processing More Issue