cover
Contact Name
Harry Budiman
Contact Email
harry@bsn.go.id
Phone
+6285718217895
Journal Mail Official
harry@bsn.go.id
Editorial Address
Kawasan Sains dan Teknologi BJ Habibie BRIN Serpong Tangerang 15314 Building 420
Location
Kota adm. jakarta pusat,
Dki jakarta
INDONESIA
Jurnal Instrumentasi
ISSN : 01259202     EISSN : 24601462     DOI : 10.31153
The scientific areas covered by Instrumentasi are those backboned by scientific measurements and thus range from instrument engineering, metrology, testing, and control. All papers submitted are refereed by bona fide reviewers from leading research institutions as well as universities prior to publication to keep their quality meet the standard of the journal. The review is carried out mainly on the basis of originality, novelty, and contribution to scientific measurement. Authors need to complete the ethical clearance form for publication.
Articles 6 Documents
Search results for , issue "Vol 48, No 1 (2024)" : 6 Documents clear
METODE ANALISIS STATISTIK HASIL PEMERIKSAAN ANTARA PADA TERMOMETER TAHANAN PLATINA Zakariya, Riza
Instrumentasi Vol 48, No 1 (2024)
Publisher : National Standardization Agency of Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v48i1.703

Abstract

Pemeriksaan antara alat ukur memegang peranan penting dalam penerapan klausul 6.4.10 dan 7.7.1 ISO/IEC 17025:2017. Pemeriksaan antara ditujukan untuk menjaga keyakinan terhadap kinerja peralatan dan menjamin keabsahan hasil pengukuran. Makalah ini menyajikan hasil penelitian tentang pemeriksaan antara standar ukuran besaran suhu, khususnya pada termometer tahanan platina. Metode statistik berupa peta kendali dan uji t sesuai Guide on Measurement Assurance oleh Komite Akreditasi Nasional diaplikasikan bersama kriteria The Western Electric Handbook dan visualisasi kernel density estimation untuk mendapatkan hasil yang lebih mendalam. Hasil analisis dengan metode statistik kemudian dibandingkan dengan spesifikasi teknis untuk memastikan keakuratan termometer tahanan platina sebagai standar kalibrasi suhu.Kata Kunci: pemeriksaan antara, termometer tahanan platina, standar ukuran suhu, peta kendali, uji t, kernel density estimation
IDENTIFIKASI SISTEM BERBASIS DATA KE DALAM MODEL NARX-FNN DENGAN EXTENDED KALMAN FILTER DALAM KONDISI PENGUKURAN YANG NOISY UNTUK SISTEM KOLOM DISTILASI Nasution, Muhammad Alifsyah Putra; Mahayana, Dimitri; Rusmin, Pranoto Hidaya; Amalia, Hayati; Zidni, Hasan
Instrumentasi Vol 48, No 1 (2024)
Publisher : National Standardization Agency of Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v48i1.625

Abstract

Pada penelitian ini, digunakan plant sistem kolom distilasi tipe batch untuk memisahkan larutan biner campuran etanol dan air. Agar dapat mengimplementasikan skema sistem kendali, diperlukan pemodelan sistem kolom distilasi. Namun, masalahnya plant sistem kolom distilasi tersebut adalah sistem yang highly nonlinear dengan terbatasnya jumlah sensor yang dimiliki untuk memperoleh semua informasi states. Akibatnya, sistem kolom distilasi diidentifikasi menggunakan pendekatan black-box modeling berbasis data input-output eksperimen memanfaatkan Artificial Neural Network (ANN) untuk memperoleh model Nonlinear Autoregressive with eXogenous inputs (NARX). Hasil dengan MSE terbaik dicapai pada kasus tanpa noise pengukuran menggunakan algoritma EKF dengan hyperparameter  yang menghasilkan MSE sebesar 6,9896e-05. Selanjutnya, dapat dilihat pula pada kasus dengan noise ringan, algoritma EKF dengan hyperparameter  mampu konvergen dengan paling cepat, yaitu pada sekitar instance ke-6. Untuk setiap kasus, secara umum, semakin kecil nilai  maka semakin cepat identifikasi sistemnya konvergen, namun dengan trade-off di mana MSE yang dihasilkan menjadi sedikit memburuk. Kata Kunci: sistem kolom distilasi, identifikasi sistem berbasis data, model NARX, algoritma EKF
EKSPERIMEN AWAL KARAKTERISASI KESTABILAN SUMBER UV BERBASIS LED PADA SISTEM KALIBRASI UV RADIOMETER Zaini, Helmi; Haekal, Muhammad Husain; Nurtjahjo, Ario Fitrianto; Putri, Apri Aminati; Shavira, Rheina Aurely; Suryani, Dini; Farhania, Wiwin; Achalik, Achalik
Instrumentasi Vol 48, No 1 (2024)
Publisher : National Standardization Agency of Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v48i1.636

Abstract

Telah dilakukan karakterisasi sumber UV berbasis LED yang digunakan untuk kalibrasi UV radiometer di laboratorium SNSU Fotometri Radiometri - BSN. Pengukuran dilakukan dengan memberikan arus konstan pada single UV High-Power LED 6565 SMD Chip yang melekat pada heatsink sirip aluminium dan dilengkapi dengan kipas pendingin. Semua parameter direkam menggunakan tiga komputer secara bersamaan menggunakan koneksi data RS232 atau USB ke instrumen ukurnya, parameter yang diukur yaitu arus dan tegangan listrik, menggunakan digital multimeter; distribusi spektral, menggunakan spektroradiometer dan intensitas cahaya menggunakan radiometer. Hasil pengukuran menunjukkan kestabilan intensitas dan distribusi spektral.
DESIGN AND BUILD THE SLIDING DRUM COLLECTOR WITH RPM COUNTER ARDUINO FOR NANOFIBER FABRICATION Nugroho, Panji Setyo; Ariyanto, Dewa Pascal; Widayani, Della Astri; Hikamiah, Luluk Arifatul; Amaratirta, Jasmine Cupid; Harjunowibowo, Dewanto; Rezeki, Yulianto Agung
Instrumentasi Vol 48, No 1 (2024)
Publisher : National Standardization Agency of Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v48i1.638

Abstract

The rotational speed of the drum collector is an important parameter to determine the morphology of the nanofiber. Currently, many researchers are modifying single nozzle into multi-nozzle to obtain a wide range of materials. However, it requires more powerful syringe-pumps or increasing their number, leading to escalated cost. In addressing this issue, the sliding drum collector with an RPM counter is proposed as a solution. This apparatus uses a DC motor 775 and a stepper motor Nema17 as the driving device and an IR-sensor as the RPM counter. The RPM counter on this apparatus has also been calibrated and obtained an accuracy value of 97.87% and a precision value of 96.45%. The performance of the sliding drum collector has been validated. The sliding drum collectors have been proven to produce wider material with an area of (389 ± 8) cm2, (66 ± 18) cm2 larger than an ordinary drum collector.
PENYIAPAN SAMPEL LARUTAN BUFFER FTALAT DAN UJI STATISTIKNYA BERDASARKAN ISO/IEC 13528:2022 PADA SKEMA UJI PROFISIENSI SNSU KIMIA-BSN Hindayani, Ayu; Permatasari, Fanny Intan; Putri, Amila Safira
Instrumentasi Vol 48, No 1 (2024)
Publisher : National Standardization Agency of Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v48i1.653

Abstract

pH merupakan salah satu parameter penting yang banyak digunakan oleh laboratorium di berbagai bidang untuk menentukan kualitas air dan produk, seperti industri, kesehatan, pangan, dan lingkungan. Sebagian besar bidang tersebut membutuhkan hasil pengukuran pH yang akurat karena hasil pengukuran pH akan berdampak pada pengambilan keputusan dan berdampak pada kehidupan manusia serta lingkungan. Salah satu cara bagi laboratorium untuk menjamin keabsahan dan keakuratan hasil pengukuran pH adalah dengan berpartisipasi dalam skema uji profisiensi. Pada tahun 2022, Laboratorium SNSU Kimia-BSN telah melaksanakan skema uji profisiensi pengukuran pH larutan buffer ftalat dengan rentang pH 3,9 – 4,5. Sebelum sampel larutan buffer ftalat dibagikan kepada peserta, Laboratorium SNSU Kimia-BSN sebagai penyelenggara uji profisiensi harus memastikan sampel yang telah dibuat bersifat homogen dan stabil sesuai persyaratan dalam ISO/IEC 17043:2023. Uji homogenitas sampel dilakukan dengan mengukur 10 botol yang diambil secara acak bertingkat dan diukur nilai pH nya menggunakan pH meter. Hasil uji statistik berdasarkan ISO/IEC 13528:2022 menunjukkan bahwa sampel larutan buffer ftalat bersifat homogen. Kemudian uji stabilitas sampel dilakukan pada suhu estimasi transportasi (40 °C) selama 4 minggu dan pada periode skema uji profisiensi. Hasil uji stabilitas menunjukkan sampel larutan buffer ftalat bersifat stabil pada suhu estimasi transportasi dan selama periode skema uji profisiensi berdasarkan ISO/IEC 13528:2022. Kehomogenan dan kestabilan sampel larutan buffer ftalat juga terlihat dari sebagian besar peserta dapat mengukur pH sampel dengan baik dan mendapatkan hasil evaluasi kinerja memuaskan menggunakan z-score, yaitu sebanyak 81,8%.Kata Kunci:, pengukuran pH, uji profisiensi, homogenitas, stabilitas,.
PENGARUH PEMASANGAN TIGA TIPE SENSOR PLAT ORIFICE PADA PENGUKURAN ALIRAN Repi, Viktor Vekky Ronald; Ratuk, Rut
Instrumentasi Vol 48, No 1 (2024)
Publisher : National Standardization Agency of Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31153/instrumentasi.v48i1.624

Abstract

Perhitungan laju aliran fluida dengan pembacaan tekanan yang hilang pada pipa yang direstriksi merupakan teknik yang paling umum digunakan dalam pengukuran aliran dalam industri. Plat orifice merupakan salah satu sensor yang dapat digunakan untuk membuat beda tekanan antara sisi upstream dan downstream. Pengaruh pengukuran aliran dengan menggunakan tiga tipe sensor plat orifice bisa dicapai bila input yang di berikan pada fluida  yang berupa flow meningkat dan berdampak pada nilai akhir dari sensor orifice tersebut yang berupa pressure loss. Dari penggunaan ketiga tipe sensor orifice konsentrik, eksentrik dan segmental, diperoleh sensor yang paling tepat di gunakan pada fluida yang berupa air adalah sensor plat orifice dengan tipe konsentrik, dengan menghasilkan pressure loss yang lebih kecil dan di tandai oleh koefisien relativ yang cukup baik. Dari hasil percobaan penggunaan sensor plat orifice dangan tipe konsentrik menghasilkan output pressure loss berkisar 192.6 (Psi) – 119.6 (Psi).

Page 1 of 1 | Total Record : 6