cover
Contact Name
Budi Setiawan
Contact Email
budisetiawantropmed@gmail.com
Phone
+6281392963848
Journal Mail Official
budi.setiawan@poltekkesjogja.ac.id
Editorial Address
Sekretariat PUI, Gedung Biru, Poltekkes Kemenkes Yogyakarta Jln. Tatabumi No 3, Banyuraden, Gamping, Sleman, Yogyakarta, Indonesia
Location
Kota yogyakarta,
Daerah istimewa yogyakarta
INDONESIA
PUINOVAKESMAS
ISSN : -     EISSN : 27467430     DOI : https://doi.org/10.29238/puinova
Core Subject : Health,
PUINOVAKESMAS Journal is a peer-reviewed and scientific journal covering publications containing articles on Applied Health Technology (appropriate technology) or related topics. Submission of articles for publication is not restricted to members of the Institute and can be written in English or Bahasa. Articles from all major disciplines of health science as well as articles of interest to the profession will be considered.
Articles 22 Documents
Differences in blood creatinine levels using mono reagent which was checked immediately and which was delayed for 5 hours at room temperature Nurhidayati Nurhidayati; Ratih Hardisari; Anik Nuryati
PUINOVAKESMAS Vol. 2 No. 2 (2021): November
Publisher : Pusat Unggulan Iptek (PUI) Poltekkes Kemenkes Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (259.265 KB) | DOI: 10.29238/puinova.v2i2.1173

Abstract

Reagents used for examination must be considered for stability. Reagents made beforehand must be used immediately because the reagent that has been opened has a shorter stability period than the reagent that has not been opened. This study aims to determine the difference in creatinine levels using a mono reagent that is immediately used and which is left in for 5 hours at room temperature. This research is a pre-experimental study with a one-group pretest-posttest research design. The research sample was the remaining serum of the patients who were examined in the laboratory of Medika Sangatta Hospital as many as 40 samples. The test results were analyzed descriptively and statistically using paired sample t-test. The results of the descriptive test showed that the difference between the mean creatinine levels using immediate reagent and those experiencing indentation for 5 hours was 0.1 with the maximum value of creatinine levels using immediate reagent and those experiencing indwelling were 1.7 mg/dl and 1.6 mg/dl. While the minimum values ??are 0.9 mg / dl and 0.8 mg / dl (p=0.003). There was a difference in creatinine levels using a mono reagent which is immediately used and which has been left standing for 5 hours at room temperature so the mono reagent that has been made should be used immediately.
Aplikasi sidik serviks untuk meningkatkan pengetahuan dan sikap tentang deteksi dini kanker serviks Dian Rahmayani; Hesty Widyasih; Tri Maryani
PUINOVAKESMAS Vol. 2 No. 2 (2021): November
Publisher : Pusat Unggulan Iptek (PUI) Poltekkes Kemenkes Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (299.396 KB)

Abstract

Cervical cancer is a malignancy originating from the cervix and is one of the causes of death in women. One of the ways to do early detection of cervical cancer is the VIA test (Visual Inspection with Acetic Acid). Women's awareness is still relatively low to do IVA tests so providing information will enhance knowledge and raise public awareness.  This research is to know the effect of the “SIDIK” Serviks application to the increase of knowledge and attitudes about VIA to reproductive women. Research design applies quasi-experiment with one group pre-test and post-test design. Post-test is done 18 days after pre-test. The research sample of 31 reproductive women. The sampling technique applies purposive sampling. The sample is determined by inclusion and exclusion criteria. The independent variable is Sidik Serviks application and the dependent variable is knowledge and attitudes about VIA. Data collection applies a questionnaire through Google Form to measure knowledge and attitudes. The data analysis uses the Wilcoxon test. The result shows that the average knowledge of pre-test was 17.77, post-test was 19.06 with p-value 0.000, average attitudes of pre-test were 61.03, post-test was 64.16 with p-value 0.000 which means there is an effect of giving Sidik Serviks application on the increase of knowledge and attitudes about VIA.

Page 3 of 3 | Total Record : 22