Jurnal Mutiara Elektromedik
ISSN : ""     EISSN : 26147963     DOI : https://doi.org/10.51544/elektromedik.v6i1
Core Subject : Engineering,
Focus : Jurnal Mutiara Elektromedik yang memuat hasil penelitian tentang kajian keilmuan Teknologi Elektromedik Scope : Teknologi Elektromedik, Teknik Elektro, Teknologi Radiologi Pencitraan, Teknologi Instrumentasi, Fisika medis, Rekam Medis dan Sistem Informasi Kesehatan
Articles 137 Documents
ANALISA KALIBRASI ALAT PHOTOTHERAPY UNIT MENGGUNAKAN PHOTOTHERAPY RADIOMETER Jesni Juwita Mendrofa; Yulizham Yulizham
JURNAL MUTIARA ELEKTROMEDIK Vol. 5 No. 1 (2021): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v5i1.3252

Abstract

Jaundice in newborns from January 2013 to December 2015, with a sample size of 223 babies. To treat jaundice in babies, Phototherapy is used. Phototherapy is the first action therapy for newborns with hyperbilirunemia. The provision of effective phototherapy is the main factor in the rapid management of hyperbilirubinemia.
RANCANG BANGUN TIMER KONTROL ALAT LAMPU ULTRA VIOLET STERILIZER DILENGKAPI SISTEM BUZZER Novriani Romaulina Saragih; Rizaldi Ibrahim
JURNAL MUTIARA ELEKTROMEDIK Vol. 2 No. 2 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v2i2.3341

Abstract

Ultraviolet lamp sterilizer is a hospital operating room sterilizer to avoid spore living species, as well as contaminated bacterial viruses from outside where by utilizing S. ultraviolet light type. Planning of this tool aims to obtain a design timer for ultraviolet lamp sterilizer equipped with a system ATMega8535 microcontroller based buzzer uses PIR sensor as an indicator of detecting objects in the operating room. Where this research begins with gathering resources, formulating problems, designing tools, designing tools, and performing function tests. After the device has been designed, the function test is performed for each circuit in the tool to work properly, where by measuring each circuit on the device to find out whether the device works according to a good system where by measuring power supply voltage, PIR sensor, ultraviolet lamp, relay, and buzzer.
ANALISA TIMER ALAT SHORTHWAVE DIATHERMY MEREK BTL 6000 Istiadi Ramadhan; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol. 2 No. 2 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v2i2.3342

Abstract

Shortwave Diathermy BTL 6000 is a therapy device that emits short waves that are used to warm up deep tissues and blood vessels. Shortwave Diathermy utilizes a certain frequency as a heat generator which is channeled into the patient's body tissues through electrodes and how does the time of therapy affect the heat of the body being treated. Research on Timer Analysis of the BTL 6000 Brand Shortwave Diathermy Tool was carried out using 3 time trials, then the timing was compared to the measuring instrument used, namely a stopwatch. The time settings used include 10 minutes, 20 minutes and 30 minutes. The BTL 6000 Brand Shortwave Diathermy Tool worked well, the device's Timer setting system worked well, and the stopwatch was used as a comparison tool for timer measurements. Timer setting with a time of 10 Minutes, there is a time difference of 12 seconds faster than the stopwatch, Frequency mode with output power of 50 Watt, frequency 300 Hz and Effect Power 6.0 Watt. , Continuous Mode with 20 Watt output power, and 20 Watt Effect Power, While on the timer setting with a time of 30 minutes, there is a difference in time of 9 seconds longer than the stopwatch, Continuous Mode with 20 Watt power output, and Effect Power 20 Watt, In this mode Continuous, the output of the tool has the same output, with output power = 20 Watts, medium effect Power = 20 Watts too.
ANALISA PEMELIHARAAN INFANT WARMER DI RUMAH SAKIT UMUM SARAH MEDAN M. Wahid Afdillah; Dzia Ur Ridha
JURNAL MUTIARA ELEKTROMEDIK Vol. 2 No. 2 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v2i2.3343

Abstract

Infant warmer is one of the live support and saving tools that is used to provide comfort and warmth to newborns, where the baby needs a temperature that is in accordance with the temperature in the mother's womb, which is between 34 °C - 37 °C. The purpose of this study was to determine the implementation of the maintenance of the Infant Warmer at Sarah General Hospital Medan. This research was conducted at Sarah General Hospital Medan Jl. Baja Raya No.10, Kec. Medan Baru by distributing questionnaires containing questions/statements. The type of research used is a descriptive method which was carried out from January 2018. The results obtained from the respondents, from 22 questionnaires there were 21 questionnaires answered Yes and 1 questionnaire answered No. It was concluded that the implementation of the maintenance of the Infant Warmer at Sarah Medan General Hospital was running properly, and was declared good.
ANALISA KERJA BLOWER PADA ALAT VENTILATOR Putri Rizky Octaria Amazihono; Siti Rahmah
JURNAL MUTIARA ELEKTROMEDIK Vol. 2 No. 2 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v2i2.3344

Abstract

Ventilator is a mechanical aid that functions to provide breathing assistance so that patients breathe easier. this study aims to determine how the blower works in mixing oxygen and what is the rotational speed of the blower when mixing. This research was conducted by the integrated laboratory of USM-I. The research method used was descriptive with the from of quantitative survey implementation. Which aims to analyze the working principle of the blower on the ventolator. This research was conducted using a Hamilton C2 ventilator. in the blower flow measurement is done from the preassure setting points 5, 15, 25, 35, 55. The results of this study indicate that the blower works welol on the ventilator and the measurement results of each blower flow value reading does not exceed the predetermined standard limit of ±10%.
RANCANG BANGUN SISTEM TEMPERATUR DAN MONITORING TIMER PADA AUTOCLAVE BERBASIS MIKROKONTROLLER ATMega 8535 Santa Lusi Sitohang; Fitria Priyulida
JURNAL MUTIARA ELEKTROMEDIK Vol. 2 No. 2 (2018): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v2i2.3345

Abstract

Autoclave is heating tool and is used to sterilize things by using high pressure and high temperature steam 121C for about 15 minutes. The purpose of this tool is to kill endospores, resistant cell produced by bacteria. This cell is resistant against heat, dehydration and antibiotic. Research has been done for the design of time controlling and monitoring system at Autoclave based on microcontroller ATMega 8535. The purpose of this research is to produce Autoclave equipped with temperature controller and time monitoring which is beneficial to save energy and time using Autoclave. This tool is also equipped with circuit to detect problem. In this research, the tool’s operational system has been programmed with Thormocouple sensory system, Water Level, so the user can decide the temperature and time to be processed next by microcontroller. The initial Autoclave has been equipped with buzzer used as an alarm when the tool is not closed well and when the tool has finished operating.
ANALISA FAKTOR mA PADA PESAWAT X-RAY GENERAL MERK ALLENGERS TYPE 325 Yusalim Azis; Samser Nababan
JURNAL MUTIARA ELEKTROMEDIK Vol. 3 No. 2 (2019): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v3i2.3347

Abstract

The analysis of the mA factor has been carried out on the X-Ray General aircraft brand Allengers type 325 which was carried out in the radiology laboratory of the Sari Mutiara Indonesia University. The problem is finding the mA accuracy by making a factor of 50 mA, 100 mA, 150 mA, 200 mA. The aim is to determine and analyze the level of accuracy of x-ray accuracy and film density.The research method used is quantitative research methods through measurement and data collection directly on the X-Ray General Allenger brand type 325, the results of the data obtained were analyzed descriptively using tables and graphs.Current accuracy (mA) measurements were carried out four times using variations of ma, including 50 mA, 100 mA, 150 mA, 200 mA, and using a voltage of 50 kV and a time of 0.25 S, and using FFD with a height of 100 cm. Good measurement results are using a capacity of 50 kV, 100 mA, 0.25 S on the X-Ray General aircraft brand Allengers type 325 which is in the radiology laboratory of Sari Mutiara Indonesia University.
RANCANG BANGUN PENGONTROL SUHU BAYI NORMAL PADA INFANT WARMER SECARA OTOMATIS Laili Marwiyah; Salomo Sijabat
JURNAL MUTIARA ELEKTROMEDIK Vol. 3 No. 2 (2019): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v3i2.3348

Abstract

Infant warmer is a device used to help maintain the warmth of a baby so that the newborn feels the temperature like in the mother's womb. In this infant warmer there are procedures and the main feature is temperature with the main aim to maintain the temperature for the baby to avoid hypothermia. The design of this tool aims to obtain the design of infant warmers using the DHT11 sensor as a temperature indicator displayed on the LCDThis research starts from the stages of gathering various sources, formulating potential problems, gathering information, designing tools, designing and conducting functional tests. This design uses a DHT11 sensor, LCD, heater and driver. After the design has been carried out, testing each series to determine whether the system works in accordance with the theory discussed If you have already done so, then design the infant warmer design using the DHT11 sensor as a temperature indicator with the display on the ATMega8535 microcontroller-based LCD already feasible to use.
RANCANG BANGUN ALAT UKUR TINGGI BADAN OTOMATIS BERBASIS ANDROID Diva Perdana; Fitria Priyulida
JURNAL MUTIARA ELEKTROMEDIK Vol. 3 No. 2 (2019): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v3i2.3349

Abstract

Design and construction of an Android-based automatic height measurement tool has been carried out. This research was made due to the demand for sophisticated medical support equipment with all the capabilities it has that continues to develop so that effective and efficient medical support equipment can be produced. This tool is designed with the aim of providing information about the measurement data of height and weight to users. Measurement results data will be sent to Android in the form of messages to be stored using the android database system storage.This research method uses qualitative methods, namely: study literature and literature and conduct experiments on the circuit design made, then test the function of the tool with a meter to determine the accuracy of the work of this tool. This tool is made by utilizing the sharp ir sensor as conversion then will sent via GSM SIM 800L, and the data is displayed via the application and SMS on the patient's AndroidThe test results show that the distance obtained is the conversion result taken from the travel time of infrared rays when they emit light and receive reflected objects. seen the percentage error value for each measurement, which allows the sensor to read errors and possible interference from the compiler program. As long as the% error does not exceed 3%, the module design for automatic height measuring instruments can be used properly.
RANCANG BANGUN SISTEM LIFE TIME PROSES PENYINARAN PADA ALAT TERAPI INFRA MERAH Aldrin Waoma; Yulizham Yulizham
JURNAL MUTIARA ELEKTROMEDIK Vol. 3 No. 2 (2019): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v3i2.3350

Abstract

The current Infrared therapy device is still operated manually and there is no data on the length of the system's irradiation time. Lack of manufacturer's Infrared devices when used by physiotherapists do not know the exact time produced by Infrared light. This can pose a risk of neglect in monitoring the length of time the patient is exposed to the radiation. To overcome these problems, an infrared therapy device is designed which is equipped with a timer / timer system based on the ATMega8535 microcontroller. With this timing / timer system, we can find out the age of the infrared lamp (life time) according to the amount of usage needed so that the lamp replacement can be estimated according to the total usage of the IR lamp. With this system, on the other hand it is very useful for physiotherapy operators where physiotherapy operators can find out the time of use / irradiation of Infrared therapy devices to patients. So it can help patients who need infrared therapy without fear of side effects due to time that is not in accordance with the required therapy process.

Page 6 of 14 | Total Record : 137