Jurnal Electrichsan
ISSN : 22528237     EISSN : 28289315     DOI : -
Jurnal Electrichsan merupakan jurnal nasional yang dikelola oleh Program Studi Teknik Elektro Universitas Ichsan Gorontalo dan diterbitkan 2 (dua) kali setahun pada bulan Mei dan November. Jurnal ini tersedia secara cetak maupun elektronik dan dapat diakses secara online serta dapat diunduh secara gratis (Open Access). Jurnal Electrichsan (p-ISSN : 2252-8237, e-ISSN : 2828-9315) merupakan sebuah terbitan berkala ilmiah yang dikelola oleh Program Studi Teknik Elektro Universitas Ichsan Gorontalo. Jurnal Electrichsan diperuntukkan bagi seluruh kalangan peniliti yang ingin mempublikasikan hasil penelitiannyanya. Adapun bidang-bidang yang termasuk dalam ruang lingkup Jurnal ini antara lain : Electrical Engineering; Power; Electronics; Instrumentation and Control; Telecommunication and Multimedia; Computer and Informatics Engineering; Signal/Image Processing; Electrical Engineering Vocational Education. Redaksi Jurnal Electrichsan Program Studi Teknik Elektro Universitas Ichsan Gorontalo mengundang para Peneliti, Akademisi, Praktisi dan Profesional untuk menyumbangkan karya tulisnya, di bidang Teknik Elektro dan Informatika, baik berupa hasil penelitian dan kajian pustaka yang belum pernah dipublikasikan sebelumnya di media lain.
Articles 5 Documents
Search results for , issue "Vol. 11 No. 2 (2022): November 2022" : 5 Documents clear
Uji Kelayakan Minyak Jarak Sebagai Bahan Isolasi Cair Pada Transformator Alim, Muhammad; Gunawan, Anggun; Kamali Amali, Lanto M; Tolago, Ade Irawaty
Jurnal Electrichsan Vol. 11 No. 2 (2022): November 2022
Publisher : Program Studi Teknik Elektro Universitas Ichsan Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37195/electrichsan.v11i2.285

Abstract

Transformator daya yang ada pada gardu induk memiliki minyak trafo. Minyak trafo ini berfungsi sebagai pemisah listrik pada kumparan primer dan sekunder agar tidak terjadi tegangan tembus. Minyak trafo tersebut berasal dari hasil tambang bumi yang tidak dapat diperbaharui. Salah satu upaya yang dapat kita lakukan untuk meminimalkan penggunaan minyak fosil adalah penggunaan minyak nabati. Minyak nabati dapat dijadikan isolasi cair alternatif pada transformator daya. Namun minyak nabati memiliki sifat kimia yang kurang stabil dan memiliki viskositas tinggi. Tujuan penelitian untuk mengetahui kelayakan minyak jarak agar dapat digunakan sebagai alternatif isolasi cair dengan menggunakan minyak trafo merek Shell Diala B sebagai pembanding. Adapun metode yang digunakan pada penelitian ini adalah melakukan pengamatan langsung terhadap objek yang di teliti untuk mengamati keadaan yang sebenarnya di lapangan. Hasil yang telah di peroleh seteleh melakukan pengujian pada sampel minyak jarak yaitu nilai kadar air sebesar 2,38 mg/kg, Massa jenis sebesar 0,911 gr/cm³, nilai viskositas sebesar 48,70 cSt dan nilai tegangan tembus sebesar 34,47 kV. The power transformer in the substation has transformer oil. This transformer oil functions as an electrical separator in the primary and secondary coils so that there is no breakdown voltage. The transformer oil comes from non-renewable mining products. One of the efforts that we can do to minimize the use of fossil oil is the use of vegetable oils. Vegetable oil can be used as an alternative liquid insulation in power transformers. However, vegetable oil has less stable chemical properties and has a high viscosity. The purpose of the study was to determine the feasibility of castor oil to be used as an alternative to liquid insulation using Shell Diala B transformer oil as a comparison. The method used in this study is to make direct observations of the object under scrutiny to observe the actual situation in the field. The results that have been obtained after testing the castor oil sample are the water content value of 2.38 mg/kg, the density of 0.911 gr/cm³, the viscosity value of 48.70 cSt and the breakdown voltage value of 34.47 kV.
Pengaruh Viskositas Dan Kadar Air Terhadap Breakdown Isolasi Minyak Transformator Shell Diala B Nirmalasari, Nirmalasari; Ariwinoto, Diki; Kamali Amali, Lanto M; Tolago, Ade Irawaty
Jurnal Electrichsan Vol. 11 No. 2 (2022): November 2022
Publisher : Program Studi Teknik Elektro Universitas Ichsan Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37195/electrichsan.v11i2.286

Abstract

Faktor yang mempengaruhi menurunnya mutu dalam ketersediaan pelayanan energi listrik adalah ganguan terhadap minyak transformator, hal ini bisa disebabkan berbagai faktor diantaranya berupa adanya kontaminasi partikel-partikel serta uap air pada transformator. Penelitian ini bertujuan untuk mendeskripsikan pengaruh viskositas dan kadar air terhadap breakdown voltage minyak transformator Shell Diala B. Metode pengujian breakdown voltage berdasarkan standar IEC 156, elektroda setengah bola dengan jarak antara elektroda 2.5 mm. Hasil pengujian viskositas dan kadar air terhadap breakdown voltage minyak transformator Shell Diala B menunjukan viskositas pada minyak transformator dapat mempengaruhi breakdown voltage minyak transformator, semakin kecil nilai viskositas yang terkandung dalam minyak transformator, maka breakdown voltage minyak transformator akan semakin besar. Demikian pula kadar air yang ada didalam minyak transformator, semakin banyak kadar air yang terkandung didalam minyak transformator maka breakdown voltage yang terjadi pada minyak transformator akan semakin cepat (buruk). The factors that affect the quality in the availability of electrical energy services are disturbances to transformer oil, this can be caused by various factors such as contamination of particles and moisture in the transformer. This study aims to describe the effect of viscosity and water content on the breakdown voltage of Shell Diala B transformer oil. The breakdown voltage test method is based on the IEC 156 standard, hemispherical electrodes with a distance of 2.5 mm between the electrodes. The results of testing the viscosity and water content of the breakdown voltage of Shell Diala B transformer oil show that the viscosity of transformer oil can affect the breakdown voltage of transformer oil, the smaller the viscosity value contained in transformer oil, the greater the breakdown voltage of transformer oil. Likewise, the water content in transformer oil, the more water content contained in transformer oil, the breakdown voltage that occurs in transformer oil will be faster (bad).
Monitoring Bearing Scavenge Oil Temperature Berbasis Internet Of Things (Iot) Pada Unit PLTU Anggrek Laleno, Wahyudin; Hulukati, Stephan A.; Asri, Muhammad
Jurnal Electrichsan Vol. 11 No. 2 (2022): November 2022
Publisher : Program Studi Teknik Elektro Universitas Ichsan Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37195/electrichsan.v11i2.287

Abstract

PLTU Anggrek merupakan salah satu pembangkit tenaga listrik yang ada di Gorontalo.Dalam beroperasinya PLTU tersebut, monitoring sistem kontrol DCS dibagi dalam tiga bagian yaitu boiler, turbin, dan auxiliary sistem (fuel and water). Pada bagian turbin dan generator terdapat ST Bearing scavenge oil yang berfungsi untuk menjaga suhu sehingga kesetabilan putaran antara poros turbin dan generator dapat terjaga dengan stabil. Proses monitoring kondisi ST Bearing scavenge oil tidak menjadi hal yang utama dibandingkan dengan Generator dan Turbin. Kurangnya pemantauan tersebut mengakibatkan tidak segera dapat diketahui sejak dini pada saat temperatur Bearing scavenge oil melebihi batas yang diperbolehkan. Dengan adanya sistem monitoring temperature berbasis IoT ini akan mempermudah dan mempercepat operator dalam mengetahui jika terjadi kenaikan temperatur dimanapun berada. Metode yang digunakan dalam penelitian ini yaitu on/off dengan prinsip kerja membaca suhu ST Bearing scavenge oil dan mengirimkan data suhu ke Smart Phone Android. Berdasarkan hasil penelitian menunjukkan hasil bahwa monitoring suhu Bearing dapat dipantau dengan Android berbasis IoT. Terdapat selisih perbedaan hasil pengukuran antara Sensor DHT11 dengan sensor pada sistem DCS PLTU rata-rata sebesar 14.7 derajat Celcius. Hal tersebut terjadi karena pengukuran DHT11 hanya diletakkan diluar sistem pendingin dari Bearing. PLTU Anggrek is one of the power plants in Gorontalo. In its operation, the monitoring of the DCS control system is divided into three parts, namely the boiler, turbine, and auxiliary system (fuel and water). In the turbine and generator section, there is ST Bearing scavenge oil which functions to maintain the temperature so that the rotational stability between the turbine shaft and the generator can be maintained stably. The process of monitoring the condition of ST Bearing scavenge oil is not the main thing compared to generators and turbines. This lack of monitoring means that it cannot be detected early when the Bearing scavenge oil temperature exceeds the allowable limit. With this IoT-based temperature monitoring system, it will make it easier and faster for operators to find out if there is an increase in temperature wherever they are. The method used in this study is on/off with the working principle of reading the ST Bearing scavenge oil temperature and sending temperature data to an Android Smartphone. Based on the results of the study, the bearing temperature monitoring can be monitored with IoT-based Android. There is a difference in the measurement results between the DHT11 sensor and the sensor on the PLTU DCS system on average 14.7 degrees Celsius. It is due to the DHT11 measurement is only placed outside the cooling system of the Bearing.
Perancangan Sistem Elektrikal Gedung Asrama Terpadu Man 1 Kota Gorontalo Gobel, Rilly; Humena, Steven; Putra Surusa, Frengki Eka; Febrianto Karinda, Abd. Razak
Jurnal Electrichsan Vol. 11 No. 2 (2022): November 2022
Publisher : Program Studi Teknik Elektro Universitas Ichsan Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37195/electrichsan.v11i2.288

Abstract

Di Indonesia sendiri, desain instalasi listrik diatur dalam Peraturan Umum Instalasi Listrik (PUIL) tahun 2011. Dalam peraturan tersebut sudah jelas bagaimana cara memasang instalasi listrik yang baik dan benar, yang merupakan standar instalasi listrik di Indonesia. Tujuan dari penelitian ini melakukan perancangan instalasi listrik pada bangunan gedung sesuai dengan Standar PUIL 2011, menentukan spesifikasi komponen dan pengaman yang dibutuhkan, menentukan besarnya daya yang digunakan untuk pengajuan langganan listrik ke PT. PLN (Persero). Metode perencanaan sistem elektrikal gedung menggunakan standar – standar yang telah ditentukan yaitu Peraturan Umum Instalasi Listrik (PUIL) 2011 dan SNI Konservasi energi pada sistem pencahayaan 2011. Hasil dari perhitungan diperoleh arus sebesar 80,16 amper, sehingga pembatas MCB induk yang dipilih dengan kapasitas 100 Amper. Untuk pengajuan layanan sambungan daya listrik kepada PT. PLN (Persero) yaitu sebesar 22.000 VA dengan pembatas MCB 100 Amper. Total Arus Maksimal yaitu 100 Amper dan nilai KHA 125 Amper, jenis dan luas penampang kabel yang dipilih untuk kabel induk berdasarkan PUIL 2011 yaitu NYM 3 x 35 mm2. In Indonesia itself, the design of electrical installations is regulated in the General Electrical Installation Regulations (PUIL) of 2011. In these regulations it is clear how to install a good and correct electrical installation, which is the standard for electrical installations in Indonesia. The purpose of this research is to design electrical installations in buildings in accordance with the 2011 PUIL Standard, determine the specifications for components and security needed, determine the amount of power used for submitting electricity subscriptions to PT. PLN (Persero). The building electrical system planning method uses predetermined standards, namely General Regulations for Electrical Installation (PUIL) 2011 and SNI for energy conservation in lighting systems 2011. The results of the calculation obtained a current of 80.16 amperes, so that the main MCB limiter is selected with a capacity of 100 Amperes. To submit an electrical power connection service to PT. PLN (Persero) which is equal to 22,000 VA with a limiter of 100 Ampere MCB. Total Maximum Current is 100 Ampere and KHA value is 125 Ampere, the type and cross-sectional area of the cable selected for the main cable based on PUIL 2011 is NYM 3 x 35 mm2.
Rancang Bangun Alat Sirkulasi Air Pada Sistem Tanaman Hidroponik Hulukati, Stephan A.; Asri, Muhammad; Pegu, Owin; Abdussamad, Syahrir
Jurnal Electrichsan Vol. 11 No. 2 (2022): November 2022
Publisher : Program Studi Teknik Elektro Universitas Ichsan Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37195/electrichsan.v11i2.289

Abstract

Hidroponik adalah cara bercocok tanam dengan hanya menggunakan air sebagai media tumbuhnya, metode hidroponik sendiri merupakan metode yang sangat sederhana mengingat metode ini tidak memerlukan lahan yang luas. Besarnya minat masyarakat terhadap sistem hidroponik ini perlu di iringi dengan kamajuan tekhnologi saat ini yang sudah canggi untuk para petani mengontrol sirkulasi air dengan baik. Metode penelitian ini membahas bagaimana merancang alat sirkulasi air pada sistem hidroponik dengan alat SR04-A. Sebagai alat control sistem tanaman hidroponik alat ini dilengkapi bagian bagian pendukung berupa, 1 buah sensor unit ultra sonic, 1 buah buzzer, dan 5 buah lampu led sebagai indicator. Dan berupa alat pemantau temperature dan kelembapan udara, yang menggunakan mikrokontroler NODE MCU dan sensor DHT11 yang mendeteksi temperature dan kelembapan udara. Penelitian ini dibuat agar para petani mengetahui bahwa membuat sistem tanaman hidroponik dengan memafaatkan teknologi pada jaman sekarang yang bisa mengotrol sirkulasi air secara otomatis pada sistem tanaman. Berdasarkan pengujian yang dilakukan di loakasi didapatkan bahwa setiap modul dapat bekerja sangat baik sesuai dengan fungsnya, outputnya adalah menggunakan pompa air untuk mengontrol keluar masuknya air pada sistem tanaman hidroponik. Dan hasil dari penelitian ini adalah sistem dapat mendeteksi jarak air 100 cm, 50, cm, 10 cm. Pada saat jarak sensor unit 100 cm maka pompa akan ON untuk menjalankan fungsinya sebagai pengaturan sirkulasi air pada sistem tanaman, dan ketika deteksi sensor sudah sampai 10 cm maka pompa akan OFF. Dan untuk pemantauan kelembapan outpunya adalah LCD dan Aplikasi Blynk. Hasil yang di dapat dari deteksi sensor unutk temeperature yang paling tinggi 43C° dan kelembapan 38%. Saran yang dapat dikembangkan pada penelitian ini adalah hanya untuk pengontrolan monitoring yang lebih baik menggunakan pompa air 2, agar bisa memonitoring kelembapan udarah lebih baik. Hydroponics is a way of growing crops using only water as a growth medium. The hydroponic method is simple since it does not require a large area of land. The amount of public interest in this hydroponic system needs to be accompanied by advances in technology that are now sophisticated for farmers to control water circulation properly. This study employs a method that discusses the design of water circulation equipment in a hydroponic planting system using the SR04-A device. As a control tool for the hydroponic planting system, this tool is equipped with supporting parts, namely 1 ultrasonic sensor unit, 1 buzzer, and 5 led lights as indicators. The temperature and humidity monitoring device uses a NODEMCU microcontroller and a DHT11 sensor that detects air temperature and humidity. It aims to help farmers that making a hydroponic planting system by utilizing today's technology that can control water circulation automatically in the plant system is simple to master. Based on the tests carried out at the location, it is found that each module can work very well following its function. The output is to use a water pump to control the entry and exit of water in the hydroponic planting system. The result of this study is that the system can detect water distances of 100 cm, 50, cm, and 10 cm. When the sensor unit distance is 100 cm, the pump will be ON to carry out its function as a water circulation regulation in the planting system. If the sensor detection has reached 10 cm, the pump will be OFF. In humidity monitoring, the outputs are the LCD and the Blynk App. It also indicates the detection of a sensor for the highest temperature of 43C ° and humidity of 38%. This study suggests that only using a water pump 2 with a better monitoring control can better monitor the humidity of the air.