Journal of ALTRON is an open-access journal published by the Study Program of Electrical Engineering, Faculty of Systems Engineering, Sumbawa University of Technology. Altron is published with a frequency of 2 (two) times a year in August and February with varying volumes, e-ISSN 2963-1033. As the National Journal of Electrical Engineering, this journal publishes journals in Indonesian which aims to be a platform for researchers and scientists to publish their research journals which can be in the form of research results, scientific studies, as well as analysis and solving relevant problems and disseminate their knowledge about Electrical Engineering, in the scope of technology, electronics, science, energy systems and related sciences. Novelty and up-to-date scientific issues as well as research originality is the priority of the Altron Journal. All articles submitted must be original research results that have never been published and are not being considered for publication elsewhere. Publication of submitted manuscripts is subject to peer review. Both general and technical aspects of submitted papers are reviewed prior to publication. Manuscripts must follow the style of the journal and be reviewable and editable. The online delivery and publishing system uses the Open Journal System (OJS). Submissions must be made online via the Altron Journal submission site.
Articles 54 Documents
EFISIENSI SISTEM KELISTRIKAN PADA GEDUNG SUMBAWA TECHNO PARK(STP) UNIVERSITAS TEKNOLOGI SUMBAWA Muhammad Surya Aqidah; Darmawan , Indra; Ariyanto, Nova; Maulidyawati , Desi; Aulia, Masyitah
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v3i2.3696

Abstract

Tingkat konsumsi dan distribusi energi listrik harus seimbang dan efisien. Akan tetapi, tidak semua sektor atau bangunan mampu memenuhi tingkat efisiensi yang telah ditentukan. Gedung Sumbawa Techno Park (STP) Universitas Teknologi Sumbawa sebagai konsumen energi listrik tingkat menengah, kiranya perlu dilakukan analisis peluang penghematan energi, guna mengetahui tingkat efisiensi konsumsi energi. Tujuan dari penelitian ini adalah untuk menganalisis peluang penghematan energi yang dilakukan melalui audit energi singkat dengan panduan Permen ESDM No. 13/2012 tentang audit energi listrik awal yang berfokus dengan luas bangunan gedung STP sekitar 720.63 (????????). Metode yang digunakan dalam penelitian ini adalah metode campuran (Mixed Method Research), Hasil dari penelitian diperoleh IKE pada kWh gedung Sumbawa Techno Park (STP) sebesar 69,93 kWh/m2/tahun. Nilai tersebut termasuk dalam kategori efisien menurut standar nilai IKE ASEAN-USAID yakni untuk gedung jenis perkantoran nilai IKE maksimum adalah 240 kWh/m2/tahun. Pada ruangan ber-AC diperoleh nilai rata-rata IKE sebesar 34,20 kWh/m2/bulan. Sedangkan pada ruangan tidak ber-AC diperoleh nilai rata-rata IKE sebesar 0,80 kWh/m2/bulan. Nilai IKE pada ruangan ber-AC dan tidak ber-AC masing-masing termasuk dalam kategori cukup efisien dan sangat efisien menurut permen ESDM No. 13/2012.
Arus kuat STUDI KELAYAKAN INSTALASI LISTRIK PADA GEDUNG STASIUN PENGISIAN BAHAN BAKAR UMUM (SPBU) PERNEK SUMBAWA Agus Hermansyah Agus; Ahmad Jaya; Indra Darmawan; Desi Maulidyawati
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v4i2.5220

Abstract

Human development cannot be separated from technology, especially electrical energy which functions as the main support in various daily activities. The use of electricity must be balanced with attention to maintenance and installation updates to avoid risks that could harm users. Several important aspects in electrical installations include the selection of materials, the installation process, and compliance with applicable regulatory standards. This research uses qualitative methods, which focus on in-depth analysis of the study object through observation, interviews, and testing of electrical installations in the laboratory. This is different from the method While the quantitative approach involves statistical analysis, the qualitative approach places more emphasis on collecting, analyzing and interpreting data to understand social problems based on natural reality. Hani from research shows that the electrical installation in the Pernek gas station building meets PUIL 2011 standards. This feasibility is determined by several factors such as panel height, contact box, switch, KWH meter, cable color, and the use of MCB as a safety cable in electrical installations are differentiated based on color: R phase is black, S phase is brown, T phase is gray, N cable is blue, and grounding cable is green-yellow. The research conclusions confirm that all installation elements-including cable color, height of contact boxes, switches, panels, KWH meters, and MCB-comply with PUII provisions. 2011 and applicable regulatory standards
ANALISIS KELAYAKAN INSTALASI LISTRIK PADA BANGUNAN SEKOLAH DASAR NEGERI LESENG BERDASARKAN PERSYARATAN UMUM INSTALASI LISTRIK (PUIL) 2011 MUHAMMAD ZULFAHRI FAUZAN; Nova Ariyanto; Nova Ariyanto; Ahmad Jaya; Paris Ali Topan; Desi Maulidyawati
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v4i1.5477

Abstract

Electrical installations are essential infrastructure in educational buildings because they ensure the safe and reliable distribution of electrical energy to support teaching and learning activities. Electrical installations that have been used for many years may experience deterioration due to aging, increased electrical loads, and inadequate maintenance, thereby increasing the risk of electrical hazards such as short circuits, electric shocks, equipment failures, and fires. This study aimed to evaluate the feasibility of the electrical installation at Leseng State Elementary School based on the General Requirements for Electrical Installations (PUIL) 2011. A descriptive research method with a field observation approach was employed through visual inspection, direct measurement, documentation, and interviews. The assessment covered the condition of Miniature Circuit Breakers (MCBs), switches, socket outlets, lamp holders, conductors, cable joints, and the conformity of the installation with PUIL 2011 standards. The results indicate that several components, including switch height, socket outlet height, and supply voltage, comply with the applicable standards. However, several deficiencies were identified, including damaged MCB covers, improper conductor colour identification, cable joints without appropriate connectors, non-standard cable branching, and damaged lamp holders. Therefore, it can be concluded that the electrical installation at Leseng State Elementary School does not fully comply with the requirements of PUIL 2011 and requires corrective actions to improve its safety, reliability, and operational feasibility.
STUDI KELAYAKAN INSTALASI LISTRIK PADA GEDUNG GELANGGANG OLAHRAGA MAMPIS RUNGAN KABUPATEN SUMBAWA SESUAI PERSYARATAN UMUM INSTALASI LISTRIK 2011 Andhika Diva Dwi Sandi; Muhammad Hidayatullah; Indra Darmawan; Ahmad Jaya
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Proses Electrical installations are systems that provide electrical power to meet human needs in everyday life. This involves distributing electric power from the distribution substations of electricity service providers to load points. In the distribution of electrical energy, general requirements for electrical installations are enforced to ensure safety because they ensure human safety and protect property from electrical hazards. Failure to comply with electrical installation regulations and standards can cause the risk of accidents, fires and other serious dangers for building occupants. These problems need to be addressed. carry out feasibility tests on electrical installations that comply with the general requirements for electrical installations in 2011 to ensure safety, reliability and quality of electrical installations. This research aims to determine the feasibility of electrical installations for the Mampis Rungan sports arena building in Sumbawa Regency. This research uses a qualitative method of observation which includes testing, Observations and interviews This research does not involve statistical analysis but focuses more on data collection, analysis and interpretation. Based on the results of inspection and testing data which have been in accordance with PUIL 2011, the Mamp?s Rungan Sports Arena Electrical Installation can be declared unfit. The unfitness factor is caused by The electrical installation system from the panel to the load point does not meet PUIL 2011 standards which include the color of the cables on the panel, and the cables that go to the load point as well as installation safety measures such as the absence of lasdopsĀ