Journal of ALTRON is an open-access journal published by the Study Program of Electrical Engineering, Faculty of Systems Engineering, Sumbawa University of Technology. Altron is published with a frequency of 2 (two) times a year in August and February with varying volumes, e-ISSN 2963-1033. As the National Journal of Electrical Engineering, this journal publishes journals in Indonesian which aims to be a platform for researchers and scientists to publish their research journals which can be in the form of research results, scientific studies, as well as analysis and solving relevant problems and disseminate their knowledge about Electrical Engineering, in the scope of technology, electronics, science, energy systems and related sciences. Novelty and up-to-date scientific issues as well as research originality is the priority of the Altron Journal. All articles submitted must be original research results that have never been published and are not being considered for publication elsewhere. Publication of submitted manuscripts is subject to peer review. Both general and technical aspects of submitted papers are reviewed prior to publication. Manuscripts must follow the style of the journal and be reviewable and editable. The online delivery and publishing system uses the Open Journal System (OJS). Submissions must be made online via the Altron Journal submission site.
Articles 51 Documents
RANCANG BANGUN SIMULATOR SURYA MENGGUNAKAN HIGH POWER LED Julian; Paris Ali Topan; Masyitah Aulia; Muhammad Hidayatullah
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i01.1747

Abstract

So far solar panel testing has been carried out using sunlight which is strongly influenced by weather factors. This research was conducted with the aim of designing and assembling a simple solar simulator using HPL. The method used is to combine six different colors of HPL with different convex lenses with certain tilts and angles so that the light rays can blend together . The results obtained are solar panels can produce the highest voltage value of 17.58 volts, the highest current value of 0.0140 amperes and the highest power value of 0.2430 watts with a luminance level of 900 lm. The solar simulator that was tested could not make the solar panel produce an output of 5 watts due to several factors such as the distance of the light source to the solar panel, the number of colors of the LED lights that were lit (spectrum and intensity of light), the angle of light and the lens used.
Pembuatan Alat Pengukur Arus Bernilai Micro Menggunakan Resistor Shunt Dan Modul Op-Amp AD620 Hastia Ningsih M. Nur; Paris Ali Topan; Titi Andriani; Ahmad Jaya
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i01.1756

Abstract

Current measuring device is still on the unit ampere and milliampere not yet on the unit micro amperage. Therefore, made a measuring instrument that can measure small currents in micro amperage. The purpose of this study is to find out how to measure current using a resistor shunt and the AD620 module on the unit microampere. The method used is the experimental method which includes: the tool design stage, the testing stage, and the data collection stage. There are 2 tool design stages, namely the first stage is the design stage for testing the MCP4725 module and the AD620 module, the second is the current measurement design stage. Test results of current measurements by varying the resistor from 10 k?-100k? to obtain different current values. When it is installed with a 10 k? resistor, it gets a current value of 0.00103 µA and when it is installed with a 20 k? resistor, it gets a current value of 0.00093. It can be seen that the greater the resistance value, the smaller the required current value and vice versa.
RANCANG BANGUN TURBIN AIR TIPE CROSSFLOW DAN PENGARUH KETINGGIAN AIR TERHADAP EFISIENSI TURBIN UNTUK PEMBANGKIT LISTRIK TENAGA PIKOHIDRO Yogi Permana; Ahmad Jaya; Muhammad Hidayatullah; Nova Aryanto
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i01.1770

Abstract

Pico Hydro Power Plant (PLTPH) is one of the innovations for the use of alternative energy so that it can increase the role and potential of existing water energy sources in an area. The research method used is the experimental method by doing type water turbine design cross flow as a prime mover for a Laboratory-scale Pico-Hydro Power Plant. There are 2 parameters for the success of this study, namely being able to make a cross flow type water turbine with a turbine rotational speed of 100 Rpm and varying the water level to determine the performance of a cross flow type water turbine. The results of the water turbine design crossflow with a diameter of 15 cm, the number of turbine blades type cross flow 13 blades, the rotational speed of the turbine without load is 299.5 Rpm while the turbine rotation with an AC generator load is 195.5 Rpm, the power generated is 0.509 Watt with a turbine efficiency of 1.5%.
RANCANG SIMULASI AUTOMATIC TRANSFER SWITCH (ATS) GENSET BERBASIS OUTSEAL PLC: Rancang Simulasi Automatic Transfer Switch (ATS) Genset Berbasis Outseal PLC firman al barqah; Paris Ali Topan; Masyitah Aulia
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i01.1794

Abstract

Planning Out seal PLC Based Generator Automatic Transfer Switch (ATS) Simulation. This thesis raises the problem that when there is a sudden power outage due to cut off of supply from the PLN, by automatically activating the generator so that it does not take longer in the transition process between the PLN supply and the generator supply. The purpose of this research is to make an ATS tool using a PLC and analyze the results of the ATS test. This research used the R&D (Research and Development) method and was conducted in the electrical engineering laboratory, Faculty of Systems Engineering, Sumbawa University of Technology. The results of the ATS simulation research that has been made are that the tool that has been designed can run according to the design and can work properly, so that in the PLN OFF condition, R5 starts the generator immediately, giving a signal and making the generator program turn on.
PERBAIKAN TEGANGAN PENYULANG KARUMBU DENGAN METODE PECAH BEBAN PADA PT. PLN (PERSERO) ULP WOHA YASYFIN NUR MUHAMMAD; Indra Darmawan; Titi Andriani; Muhammad Hidayatullah
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i02.2177

Abstract

The electrical energy that is distributed to customers is connected to the distribution network. Within the scope of the electricity distribution network, there are problems, namely the rating capacity that exceeds the feeder load and the length of the network on the feeder. This is dangerous because the load being served is too far away, and the excessive load will increase the current flowing through the conductor. so that it causes the voltage to drop to the customer, and if there is a feeder disturbance, it will expand the blackout area. Power loss is a problem that has always been faced by PT. PLN (Persero) and is unavoidable. This is also similar to the conditions that occurred at PT. PLN (Persero) ULP Woha, where the load on the Karumbu feeder is too heavy with a capacity of up to 91 amperes and a feeder length of 167 kMs. One of the solutions offered is the need to solve the feeder and plan for the construction of the Monta switch substation to reduce the load and length of the Karumbu feeder by simulating using ETAP 12.6.0 software. Based on the simulation results using the ETAP 12.6.0 software, the voltage at the end of the Karumbu feeder was obtained from 18.087 kV to 18.885 kV after solving the feeder load. The benefits that will be obtained later are reducing the burden on the Karumbu feeder and improving the voltage on the 20 kV and customer sides.
SIMULASI PERBAIKAN TEGANGAN JATUH PENYULANG RONTU PT PLN (PERSERO) ULP BIMA KOTA MENGGUNAKAN APLIKASI ETAP 12.6.0 Choiruzzad Fahri; Paris Ali Topan; Masyitah Aulia; Nova Aryanto
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i02.2251

Abstract

Menurut UU No. 30 Tahun 2009 pasal 28 tentang ketenagalistrikan, bahwa pemegang izin usaha penyediaan tenaga listrik wajib menyediakan tenaga listrik yang memenuhi standar mutu keandalan yang berlaku. Dalam sistem tenaga listrik, khususnya pada Jaringan Tegangan Menengah 20 kV terdapat penyulang distribusi primer radial pada jaringan PT PLN (Persero) UP3 Bima ULP Bima Kota yaitu Penyulang Rontu. Penyulang Rontu menyalurkan energi listrik untuk konsumen rumah tangga dan konsumen bisnis di wilayah Kecamatan Raba dan sebagian Kecamatan Rasanae Barat, Kota Bima. Dengan panjang penyulang 49 kms dan beban puncak malam sebesar 3361 kW. Dilakukan pengukuran tegangan ujung dilapangan sebesar 18.92 kV yang menyebabkan nilai tegangan jatuhnya sebesar 5.42% sehingga tidak sesuai standar SPLN No. 72 Tahun 1987, yang mengatur nilai tegangan jatuh pada SUTM 5% dari tegangan kerjanya. Skripsi ini membahas tentang langkah untuk memperbaiki tegangan dengan metode pecah beban yang disimulasi pada aplikasi. Dalam skripsi ini menggunakan aplikasi ETAP 12.6.0 dan simulasi akan dilakukan dengan dua kondisi, yaitu: 1) kondisi eksisting Penyulang Rontu, dan 2) kondisi Penyulang Rontu dipecah beban penyulang. Hasil simulasi menunjukkan bahwa metode perbaikan tegangan dengan melakukan pecah beban dapat menurunkan tegangan jatuh pada Penyulang Rontu sebesar 78.70% dari semula 18.92 kV menjadi 19.77 kV
PERANCANGAN PEMANFAATAN ENERGI BARU TERBARUKAN BERBASIS TENAGA HIBRIDA UNTUK MENINGKATKAN RASIO ELEKTRIFIKASI (STUDI KASUS: KECAMATAN TULAKAN, KABUPATEN PACITAN) Sri Anggoro Prahastono; Ahmad Agus Setiawan; Wahyu Wilopo
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i02.2766

Abstract

Salah satu daerah yang memiliki rasio elektrifikasi rendah terdapat di Kecamatan Tulakan, Kabupaten Pacitan, Jawa Timur. Padahal, potensi Energi Baru Terbarukan masih banyak yang dapat dimanfaatkan. Pada daerah tersebut, terdapat potensi energi surya, angin, dan biogas yang tinggi untuk dikembangkan agar penduduk sekitar mendapatkan aliran listrik yang sesuai dengan kebutuhan. Tujuan dari penelitian ini adalah untuk mensimulasikan Energi Baru Terbarukan berbasis tenaga surya, tenaga angin, dan biogas yang ada di Kecamatan Tulakan, agar dapat memperoleh kombinasi terbaik. Dengan melakukan simulasi menggunakan perangkat lunak HomerPro, didapatkan kombinasi konfigurasi yang bersifat Off-grid. Konfigurasi terbaik yang telah didapatkan terdiri dari kombinasi Panel Surya, Turbin Angin, dan Biogas. Konfigurasi ini memproduksi listrik hingga 11.590 kWh/tahunnya, dimana persentase produksi energi terbesar dari Turbin Angin sebesar 65,9%, Panel Surya sebesar 25%, dan biogas sebesar 9,1%. Konfigurasi ini menghasilkan emisi CO2 dari generator biogas sebanyak 1.324 kg/tahun dan membutuhkan biaya investasi awal sebesar Rp 2.317.119.450. Penerapan dari konfigurasi ini dapat meningkatkan rasio elektrifikasi hingga 100%
ANALISIS PELEPASAN BEBAN (LOAD SHEDDING) MENGGUNAKAN UNDER FREQUENCY RELAY (UFR) PADA SISTEM KELISTRIKAN TAMBORA Jenal; Ahmad Jaya; Desi Maulidyawati; Indra Darmawan
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i02.2999

Abstract

Gangguan kelistrikan dapat menyebabkan penurunan frekuensi yang berimbas padakegagalan unit-unit pembangkit secara berurutan sehingga mengakibatkan kegagalan sistemtotal. Penelitian ini ditujukan untuk mempertahankan frekuensi dengan melakukan pelepasan beban secara bertahap agar tidak terjadi gangguan sistem yang lebih luas. Metode yangdigunakan adalah metode kuantitatif eksperimen dan analisis data dilakukan denganperhitungan. Didapatkan laju penurunan frekuensi (df/dt) PLTMG Sumbawa unit 3 suplaidaya 7,5 MW sebesar – 0,23395415 Hz/detik dan melakukan pelepasan beban eksistingsebesar 7,53 MW saat mencapai UFR tahap 1 49,2 ? 49,1922239 Hz, ketika suplai daya 15MW laju penurunan frekuensi (df/dt) sebesar – 0,536020905 Hz/detik dan melakukanpelepasan beban eksisting sebesar 15,41 MW saat mencapai UFR tahap 1 49,2 ?49,19473508 Hz sebesar 7,53 MW dan saat mencapai UFR tahap 2 49,0 ? 48,99382761 Hzsebesar 7,61 MW, kemudian melakukan pelepasan beban alternatif sebesar 17,76 MW saatmencapai UFR tahap 1 49,2 ? 49,19473508 Hz sebesar 7,53 MW dan saat mencapai UFRtahap 2 49,0 ? 48,99382761 Hz sebesar 10,23 MW
ANALISIS RUGI-RUGI DAYA AKIBAT SHADOW PADA PHOTOVOLTAIC DI PEMBANGKIT LISTRIK TENAGA SURYA (PLTS) SENGKOL, LOMBOK TENGAH Aprizal Rizki; Ahmad Jaya; Nova Aryanto; Muhammad Hidayatullah
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i02.3094

Abstract

Pembangkit Listrik Tenaga Surya on grid Sengkol, Lombok Tengah, Nusa Tenggara Barat(NTB) tersusun dari kumpulan modul surya (photovoltaic), array, inverter, kabel string, danperalatan pengaman yang dirangkai dalam satu kesatuan sistem. Masing-masing darikomponen tersebut memiliki peran dalam menyalurkan energi listrik yang dihasilkanphotovoltaic ke PLN. Terdapat banyak masalah yang terjadi pada PLTS Sengkol, salah satumasalah yang sering terjadi adalah terjadinya losses atau rugi-rugi daya pada photovoltaicyang disebabkan oleh shadow (bayangan) yang menutupi photovoltaic. Lossesmerupakan kebocoran daya atau daya yang hilang di sepanjang jalur penyaluran tenagalistrik. Penelitian ini bertujuan untuk memaksimalkan daya listrik yang dihasilkan olehPLTS. Bayangan adalah suatu cahaya terhalang sesuatu benda, maka terbentuklah bayangbayang. Beberapa penelitian menunjukkan produksi listrik yang dihasilkan photovoltaicmengalami penurunan karena adanya efek bayangan, hal ini berlaku jika diamatai padaphotovoltaicKarena semakin kecil losses yang terjadi, maka semakin besar produksi dayalistrik yang dihasilkan. Bayangan disebabkan oleh terjadinya gerak semu matahari. Geraksemu matahari disebabkan oleh rotasi bumi berada pada porosnya dimana bumi berputar dariarah barat ke timur sehingga seolah-olah matahari bergerak dari timur ke barat. Metode yangdigunakan pada penelitian ini adalah adalah metode kuantitatif yaitu metode yangmenghitung dan menganalisa losses yang terjadi. Berdasarkan hasil perhitungan dan analisayang telah dilakukan diperoleh rugi-rugi daya akibat bayangan sebesar 1,98% yangdihasilkan oleh photovoltaic. Rugi-rugi daya sebesar 1,98% dinyatakan masih berada padanilai aman
RANCANG BANGUN ALAT PENDETEKSI KEBOCORAN GAS LPG BERBASIS INTERNET OF THING (IoT) DENGAN PENUTUP KATUP OTOMATIS MENGGUNAKAN MOTOR SERVO Andry Shaputra; Titi Andriani; Ahmad Jaya; Nova Aryanto
Jurnal Altron Jurnal Elektronika, Sains & Sistem energi
Publisher : Program Studi Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51401/altron.v2i02.3107

Abstract

Kebocoran tabung gas LPG menjadi penyebab utama dalam kasus terjadinya kebakaran yang disebabkan rusaknya selang gas, tidak bagusnya dalam pemasangan regulator, serta tekanan yang kuat pada LPG yang mengandung unsur propana dan butana yang sangat mudah terbakar. Pada penelitian ini dirancang alat yang dapat mendeteksi ada kebocoran gas LPG menggunanakan sensor MQ-6. Oleh microcontroller Wemos ESP32, Informasi tentang terjadinya kebocoran gas LPG ini selanjutnya digunakan untuk mengendalikan motor servo dan buzzer. Jika terjadi kebocoran gas LPG, motor servo akan menarik katup regulator pada tabung gas LPG untuk membuka katup regulator. Pada saat yang bersamaan buzzer akan berbunyi 3 kali. Selain itu, mikrokontroler akan mengirim notifikasi ke perangkat smartphone. Hasil pengujian menunjukan bahwa alat pendekti kebocoran gas LPG yang dirancang dapat bekerja dengan baik.