cover
Contact Name
sulistiyanto
Contact Email
wjowo2020@gmail.com
Phone
+6289618729653
Journal Mail Official
akiratechjurnal@gmail.com
Editorial Address
PERUM BUMI BULU INDAH Gg. Rambutan No.1A RT:01/RW: 06, Desa BULU Kecamatan KRAKSAAN Probolinggo, JAWA TIMUR
Location
Kab. probolinggo,
Jawa timur
INDONESIA
Akiratech
Published by CV. Akira Java Bulu
ISSN : 30477522     EISSN : 30477522     DOI : -
Information Technology Software Engineering Data Mining Multimedia Mobile Computing Parallel / Distributed Computing Artificial Intelligent Computer Graphic AR/VR Geographic Information System Communication Systems Telecommunication Wireless Communications Computer Network Power Systems Generator Power Distribution Electrical Power Convertion Protection Systems Electrical Material Signal, System, and Electronics Digital Signal Processing Image Processing Robotic Systems Control Systems Embedded Systems
Articles 3 Documents
Search results for , issue "vol. 3 no. 3 (2026)" : 3 Documents clear
Analisis Emergency Backup System Saat Blackout Di PLTU Batang Dina Mariani; Dicky Dicky; Achmad Achmad
Akiratech Vol. 3 No. 3 (2026)
Publisher : CV. Akira Java Bulu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.63935/akiratech.v3i3.361

Abstract

PLTU Batang yang berkapasitas 2x1000 MW dan mensupply interkoneksi jawa-bali, mengingat kapasitasnya yang besar dan juga kebutuhan daya yang dihasilkan membutuhkan Emergency Backup System yang andal untuk mengamankan peralatan kritis saat terjadi Unit Blackout maupun Plant Blackout. Penelitian ini bertujuan menganalisis sekuensial kerja, waktu respon, mitigasi ketika kegagalan terjadi serta strategi pemeliharaan pada Emergency Backup System yang meliputi Emergency Diesel Generator (EDG), dan sistem Baterai Uninterruptible Power Supply (UPS). Metode penelitian yang digunakan adalah kualitatif deskriptif dengan pendekatan Miles dan Huberman melalui studi literatur, observasi, diskusi, serta analisis data rekaman Sequence of Event Recorder (SER) aktual, simulator, dan manual book. Hasil dalam penelitian ini menunjukkan bahwa sekuensial kerja otomatis berlangsung melalui empat fase utama: deteksi gangguan oleh relai proteksi, pelepasan beban (load trip), peralihan daya oleh Baterai/UPS, EDG maupun Unit operasi normal, dan pemulihan beban. Untuk waktu respon sistem pada Baterai/UPS sebesar 0 milidetik (tanpa jeda) dan mampu mem-backup beban kritis dan komputer kontrol DCS selama 90 menit. Sementara itu, EDG berhasil auto-start hingga penutupan circuit breaker (CB) dalam waktu 11 detik untuk memulihkan tegangan Busbar Esensial 400V, lebih cepat dari batas standar manual book yaitu 15 detik. Kegagalan pada emergency backup berpotensi memicu Total Station Blackout yang menyebabkan pembengkokan poros turbin. kebocoran dan ledakan hidrogen generator, serta hilangnya visibilitas sistem kontrol DCS (black station). Dengan penerapan strategi pemeliharaan secara berkala terbukti efektif menjaga kesiapan.
Design and Performance Evaluation of an Arduino Uno-Based Robot for Automated Food Delivery in Restaurants jecky dethan; Almido H. Ginting; Sulistiyanto; Rini Akmeliawati
Akiratech Vol. 3 No. 3 (2026)
Publisher : CV. Akira Java Bulu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.63935/akiratech.v3i3.383

Abstract

The increasing adoption of automation technologies in the hospitality industry provides opportunities to support repetitive restaurant service activities, particularly food delivery. This study aims to design and implement an Arduino Uno-based waiter robot capable of delivering food to designated customer tables based on user input. The developed robot integrates an Arduino Uno as the main controller, an L298N motor driver for DC motor control, DC motors for movement, a push button for destination selection, TCRT5000 sensors for line tracking, an LCD for displaying the selected destination, and a battery as the power source. The robot operates using predefined line-following routes and programmed direction selection at intersections. Experimental results showed that the robot successfully followed the designated routes and delivered food according to the selected destination. The system also demonstrated the capability to deliver food to two customer tables within a single delivery operation. These results demonstrate the feasibility of the proposed Arduino-based waiter robot for supporting basic automated food-delivery tasks in restaurant environments.
Rancang Bangun Sistem PLTS Sebagai Sumber Daya Cadangan Berbasis ATS Untuk Mengamankan Proses Penyimpanan Data Komputer Kantor Saat Pemadaman PLN arikusuma dewa; Reza Rahmadian; Aditya Chandra Hermawan; ALFARID HENDRO YUWONO
Akiratech Vol. 3 No. 3 (2026)
Publisher : CV. Akira Java Bulu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.63935/akiratech.v3i3.385

Abstract

Penelitian ini bertujuan untuk merancang dan membangun sistem Pembangkit Listrik Tenaga Surya (PLTS) sebagai sumber daya cadangan berbasis Automatic Transfer Switch (ATS) untuk mengamankan proses penyimpanan data komputer kantor saat terjadi pemadaman listrik dari PLN. Sistem yang dirancang terdiri atas panel surya, baterai, Solar Charge Controller (SCC), inverter, ATS, relay, serta beban berupa komputer kantor. Mekanisme ATS diterapkan untuk melakukan perpindahan sumber daya secara otomatis dari jaringan PLN ke sistem PLTS ketika terjadi pemadaman, sehingga kontinuitas suplai listrik tetap terjaga tanpa memerlukan pengoperasian secara manual. Pengujian dilakukan terhadap performa panel surya, waktu perpindahan sumber daya, lama backup, serta perbandingan kinerja PLTS dengan genset sebagai sumber daya cadangan. Hasil pengujian menunjukkan bahwa tegangan keluaran panel surya berada pada rentang 26,8–35,6 V, dengan daya maksimum mencapai 180,2 W pada pukul 12.00 WIB. Sistem ATS mampu melakukan perpindahan sumber daya dari PLN ke PLTS dengan jeda suplai sebesar 7–16 ms, sedangkan perpindahan menggunakan genset memerlukan waktu 8,5–15,2 detik. Lama backup sistem PLTS berkisar antara 1,17–1,19 jam, sedangkan genset mampu memberikan backup selama 1,20–1,30 jam. Selain itu, penggunaan PLTS tidak menghasilkan kebisingan maupun emisi, berbeda dengan genset yang menghasilkan tingkat kebisingan sebesar 82,8–88,6 dB selama pengoperasian. Berdasarkan hasil pengujian tersebut, sistem PLTS berbasis ATS mampu menjaga kontinuitas suplai listrik sehingga proses penyimpanan data pada komputer kantor tetap berlangsung dengan aman saat terjadi pemadaman PLN. Sistem yang dikembangkan juga memberikan solusi sumber daya cadangan yang lebih ramah lingkungan, efisien, dan layak diterapkan pada lingkungan perkantoran.

Page 1 of 1 | Total Record : 3