cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota bandung,
Jawa barat
INDONESIA
REKA GEOMATIKA
ISSN : -     EISSN : -     DOI : -
Core Subject : Science,
Arjuna Subject : -
Articles 96 Documents
Pemetaan Eksterior Gedung 3 Dimensi (3D) Menggunakan Electronic Total Station (ETS) Rinaldy, -; Hidayat, Rahmat Taufik
REKA GEOMATIKA Vol 2016, No 1
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1061.256 KB) | DOI: 10.26760/jrg.v2016i1.1836

Abstract

ABSTRAKSaat ini masih banyak orang yang melakukan pemetaan 2D, tetapi seiring berkembangnya teknologi pemetaan secara 3D mulai dikembangkan. Pada studi ini kegiatan pemetaan dilakukan dengan metode terestris dengan melakukan pengukuran sudut dan jarak untuk mendapatkan posisi berupa x, y, z dan data keruangan berupa panjang, lebar, dan tinggi. Pada studi ini, pemetaan 3D lebih dikembangkan dengan melakukan pengukuran metode terestris dengan menggunakan alat Electronic Total Station (ETS). Namun, tidak semua objek dapat diukur menggunakan alat ETS, dikarenakan wilayah pengukuran terletak pada daerah yang padat dengan bangunan gedung sehingga membatasi ruang gerak pengukuran. Dari hasil studi ini dapat disimpulkan sebagai berikut: (1) pengambilan data detail situasi tidak hanya mengambil batas-batas atap dari setiap objek, melainkan setiap detail objek-objek seperti pilar, pintu, jendela, tangga, atap, rangka atap, ventilasi; (2) titik-titik detail situasi yang diukur adalah sudut-sudut dari setiap detail objek di mana titik-titik detail situasi yang diukur menggunakan metode seperti metode polar dan metode trigonometri; (3) data detail situasi yang diolah adalah posisi vertikal (z) untuk mendapatkan beda tinggi. Beda tinggi tersebut digunakan untuk penggambaran objek 3D; (4) peta 3D yang dihasilkan sesuai dengan posisi, ukuran, dan bentuknya.Kata kunci : Pemetaan 3D, ETS, Level of Detail, Metode TrigonometriABSTRACTCurrently there are many people who do 2D mapping, but as the development of a 3D mapping technology was developed. In this study mapping exercise carried out by terrestrial methods by measuring the angle and distance to get the position in the form of x, y, z and spatial data such as length, width and height. In this study, the 3D mapping is developed by measuring the terrestrial method by using the Electronic Total Station (ETS). However, not all objects can be measured using the ETS, because the measuring region lies in a dense area with buildings that limits the space of measurement. The results of this study can be summarized as follows: (1) retrieval of detailed data of the situation not only take the roof boundaries of each object, but every detail of objects such as pillars, doors, windows, stairs, roof, roof truss, ventilation; (2) the detail points of the situation measured are the angles of each detail of the object in which the detail points of the situation are measured using methods such as polar methods and trigonometric methods; (3) the processed data of detail situation is vertical position (z) to obtain a height difference, which used for 3D object depiction; (4) the resulting 3D map matches the position, size, and shape.Keywords: 3D Mapping, ETS, Level of Detail, Trigonometry Method
Pemanfaatan Unmanned Aerial Vehicle (UAV) Jenis Quadcopter untuk Percepatan Pemetaan Bidang Tanah (Studi Kasus: Desa Solokan Jeruk Kabupaten Bandung) Hartono, Dhiky; Darmawan, Soni
REKA GEOMATIKA Vol 2018, No 1
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (534.807 KB) | DOI: 10.26760/jrg.v2018i1.2655

Abstract

ABSTRAKPendaftaran Tanah Sistematik Lengkap (PTSL) merupakan kegiatan pendaftaran tanah untuk pertama kali yang dilakukan secara serentak di Indonesia. Program PTSL dimulai pada tahun 2016 dan ditargetkan selesai pada tahun 2025. Dengan luas darat Indonesia mencapai 2,01 juta km2, dibutuhkan teknologi yang dapat mempercepat program PTSL, di antaranya menggunakan pesawat tanpa awak (drone). Tujuan dari penelitian ini adalah untuk mengetahui sejauh mana kemampuan unmanned aerial vehicle (UAV) jenis Quadcopter untuk pemetaan bidang tanah yang ditinjau dari ketelitian, biaya, dan kecepatan. Daerah yang akan dikaji merupakan daerah yang sedang melaksanakan program PTSL yaitu Desa Solokan Jeruk Kecamatan Solokan Jeruk Kabupaten Bandung. Metodologi penelitian terdiri atas akuisisi data menggunakan UAV jenis Quadcopter dan proses pengolahan foto menggunakan perangkat lunak Agisoft Photoscan yang digeoreferensikan dengan ground control points (GCP) yang didapat dari pengamatan GPS Stop and Go. Hasil penelitian ini menunjukkan UAV jenis Quadcopter dapat mempercepat program PTSL dengan tingkat akurasi 96%, kecepatan penyediaan peta kerja atau peta dasar untuk program PTSL kurang dari 5 hari untuk luasan 1000 Ha, namun dengan biaya yang cukup tinggi.Kata Kunci: PTSL, UAV jenis Quadcopter, Ground Control Point (GCP) ABSTRACTComplete Systematic Land Registration (CSLR) is a land registration activity for the first time that is carried out simultaneously in Indonesia. The PTSL program was started in 2016 and targeted for completion by 2025. With Indonesia's land area reaching 2.01 million km2, technology is needed that can accelerate the CSLR program, one of which is using a drone. The purpose of this research is to know the extent of Unmanned Aerial Vehicle (UAV) capability of Quadcopter type for mapping of plot of land in terms of accuracy, speed, and economics. The study area is area that is being implemented the program, which located in the village of Solokan Jeruk, Solokan Sub-District, Bandung Regency. The research methodology consists of data acquisition by using UAV type Quadcopters and photo processing using Agisoft Photoscan software that will be georeferenced to the Ground Control Point (GCP) that is obtained from the GPS Real Time Kinematic observation using the Stop and Go method. The results of this study indicate that the UAV type Quadcopter can accelerate the CSLR program by providing 96% accuracy, and the speed of providing a work map or base map for CSLR program of less than 5 days for 1000 Ha, but at a high cost.Keywords: CSLR, UAV type Quadcopter, Ground Control Point (GCP)
Identifikasi Perubahan Garis Pantai dan Ekosistem Pesisir di Kabupaten Subang Handiani, Dian N; Darmawan, Soni; Hernawati, Rika; Suryahadi, Muhammad F; Aditya, Yohanes D
REKA GEOMATIKA Vol 2017, No 2
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (379.715 KB) | DOI: 10.26760/jrg.v2017i2.1765

Abstract

ABSTRAKPenelitian ini adalah kajian awal dari valuasi ekonomi atas manfaat dan jasa ekosistem di pesisir Subang. Faktor-faktor utama dalam valuasi adalah keberadaan ekosistem dan perubahan di pesisir, serta manfaat dan jasa ekosistemnya. Estimasi perubahan garis pantai dihitung berdasarkan tumpang susun data satelit Landsat tahun 1988, 1996, 2003, dan 2016. Estimasi menunjukkan terjadi perubahan garis pantai sebesar 8,17 km sejak tahun 1988-2013. Perubahan tersebut didominasi oleh sedimentasi dan abrasi sepanjang pantai. Sedimentasi tertinggi terjadi di Kecamatan Pusakanagara (869,9 ha) dan Blanakan (725,4 ha), serta abrasi tertinggi terjadi di Kecamatan Legonkulon (885,8 ha). Ekosistem alami yang berubah dan dimanfaatkan secara intensif di pesisir Subang adalah kawasan estuari dan mangrove. Sehingga mengakibatkan penurunan fungsi ekologi pada ekosistem tersebut. Adapun lahan tambak sebagai ekosistem buatan yang menggantikan kawasan mangrove, hanya berfungsi sebagai penyedia kebutuhan pangan. Penelitian ini menunjukkan perlunya valuasi ekonomi atas lahan mangrove versus budidaya tambak di Kecamatan Legonkulon, serta kawasan estuari yang berfungsi sebagai sarana transportasi di Kecamatan Pusakanagara.Kata kunci: garis pantai, ekosistem pesisir, erosi, sedimentasi, SubangABSTRACTThis research is a preliminary study for economic valuation of coastal services and goods in Subang Regency. Main factors in the valuation are ecological existing, changing, services and goods of coastal ecosystem. Coastline changes estimation was based on the overlay of Landsat satellite image at year of 1988, 1996, 2003, and 2016. Estimation shows since year of 1988 to 2013 there is changing of coastline around 8,17 km. The changes are dominantly caused by coastline sedimentation and abrasion. Higher sedimentation occured in Pusakanagara (869,9 ha) and Blanakan (725,4) Subdistrict, while highest abrasion occured in Legonkulon (885,8 ha) Subdistrict. Estuary and mangrove forests are natural ecosystem that had been used intensively and changing very excessively in this region. These changing causes degradation in functions of these ecosystems. Meanwhile, changing of mangrove forest into aquaculture only provides food. This research shows the necessity in economic valution of mangrove forest versus aquaculture in Legonkulon Subdistrict, and also estuary as transportation function in Pusakanagara Subdistrict.Keywords: coastline, coastal ecosystem, erosion, sedimentation, Subang
Evaluasi Kesiapan Implementasi Infrastruktur Data Spasial untuk Manajemen Penanggulangan Bencana -, Herlina; -, Sumarno; -, Indrianawati
REKA GEOMATIKA Vol 2017, No 1
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (200.013 KB) | DOI: 10.26760/jrg.v2017i1.1466

Abstract

ABSTRAK Akses data spasial yang cepat dan akurat mempunyai peranan yang penting dalam pengambilan keputusan untuk manajemen penanggulangan bencana. Infrastruktur Data Spasial (IDS) merupakan suatu cara untuk memudahkan pengguna untuk mengakses data spasial secara konsisten, mudah, dan aman. Dengan kata lain, IDS dapat meningkatkan ketersediaan data, kemudahan dalam akses, dan implementasi data spasial dalam pengambilan keputusan. Dalam hal manajemen penanggulangan bencana, BPBD dan stakeholder kebencanaan Kabupaten Bandung belum mengimplementasikan IDS kebencanaan. Tujuan penelitian ini adalah menentukan model IDS kebencanaan dan mengevaluasi kesiapan implementasi dalam manajemen penanggulangan bencana di Kabupaten Bandung. Metode yang digunakan dalam penelitian adalah penentuan model IDS kebencanaan yang mengacu pada model IDS yang dirumuskan oleh Rajabifard kemudian didetailkan dengan indikator penilaian IDS yang dikeluarkan Badan Informasi Geospasial tahun 2016. Pengambilan data dilakukan pada 18 stakeholder kebencanaan Kabupaten Bandung dengan wawancara, kuesioner, dan penilaian melalui website. Hasil evaluasi dari kesiapan implementasi IDS kebencanaan Kabupaten Bandung adalah 45,8%. Kata kunci: Infrastruktur Data Spasial, Manajemen Penanggulangan Bencana, Kabupaten Bandung ABSTRACT Fast and accurate spatial data access has an important role in decision making for disaster management. Spatial Data Infrastructure (SDI) is a way to facilitate the users to access spatial data consistently, easily, and safety. In the case, SDI can improve data availability, ease of access and implementation of spatial data for decision making. In disaster management, BPBD and disaster stakeholders in Bandung District have not implemented SDI of disaster. The objective of this study is to determine the SDI model of disaster and evaluate the readiness of implementation in disaster management in Bandung District. The method used in this study is determining SDI model of disaster, referred to IDS model which is formulated by Rajabifard, and then the SDI model of disaster is detailed by SDI assessment indicator issued by Geospatial Information Agency (2016). The data collection has been taken on 18 disaster stakeholders in Bandung District with interview, questionnaire, and assessment through the website. The evaluation result of the readiness of implementation the SDI of disaster in Bandung District is 45.8%. Keywords: Spatial Data Infrastructure, Disaster Management, Bandung District
Pengaruh Jenis Target Sasaran Bidikan pada Pengukuran Jarak Hasil Pengukuran Electronic Total Station Reflector-less -, Rinaldy; Setiadi, A.S.; Basyid, M.A.
REKA GEOMATIKA Vol 2017, No 2
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (465.868 KB) | DOI: 10.26760/jrg.v2017i2.1770

Abstract

ABSTRAKElectronic Total Station (ETS) merupakan gabungan dari alat ukur sudut dan jarak digital serta unit pemrosesan dan unit perekaman data. ETS Reflector-less merupakan sistem pada ETS untuk Electronic Distance Meter (EDM) atau alat pengukur jarak tanpa reflector. Spesifikasi ketelitian jarak reflector-less pada alat ETS Hi-Target ZTS 320R adalah sebesar (3mm + 2ppm x D) mm, dimana D adalah panjang jarak ukuran dalam satuan kilometer. Pada penelitian ini dilakukan kajian pengaruh jenis target terhadap kualitas hasil pengukuran ETS Reflector-less. Perbandingan jarak antara pita ukur baja dan ETS reflector-less dilakukan sebanyak 30 kali dengan jarak 20 m, 30 m, dan 50 m untuk masing-masing jenis target tembok bangunan, besi, kayu dan tanah. Hasil yang diperoleh ketelitian jarak reflector-less untuk jenis target tembok bangunan sebesar ± 0.002 m, jenis target besi sebesar ± 0.002 m, jenis target kayu sebesar ± 0.001 m, dan jenis target tanah sebesar ± 0.002 m.Kata kunci: ketelitian, jarak, reflector-less, ETS Hi-Target ZTS 320RABSTRACTElectronic Total Station (ETS) is a combination of reflector-less digital angle and distance measuring devices as well as processing units and data recording units. Reflector-less is a system on ETS for Electronic Distance Meter (EDM) or a distance meter without reflector. The specification of the accuracy of the reflector-less distance on the ETS Hi-Target ZTS 320R is equal to (3mm + 2ppm x D) mm, where D is the length of the distance distance in kilometers. This research aims to study the influence of the type of target on the accuracy of measurement results derived from ETS Reflector-less. The comparison of distance measurements between steel measuring tape and ETS reflector-less were performed 30 times with spacing of 20 m, 30 m, and 50 m for each target type, i.e building wall, iron, wood and soil. The accuracy of the ETS reflector-less distance for the building wall target type is ± 0.002 m, the target type of iron is ± 0.002 m, the target type of wood is ± 0.001 m, and the target type of land is ± 0.002 m.Keywords: accuracy, distance, reflector-less, ETS Hi-Target ZTS 320R
Perbandingan Hasil Pengolahan Data GPS Menggunakan Hitung Perataan Secara Simultan dan Secara Bertahap RUDIANTO, BAMBANG; -, RINALDY; AFANDI, M. ROBBY
REKA GEOMATIKA Vol 1, No 2 (2013)
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/jrg.v1i2.490

Abstract

ABSTRAKSecara teknis operasional, hitung perataan jaring data hasil survei GPS dapat dilakukan melalui dua cara yaitu: secara simultan dan secara bertahap. Perataan secara simultan dilakukan dengan cara meratakan vektor jarak 3 dimensi (Δx, Δy, Δh) secara serentak. Perataan secara bertahap dilakukan dengan cara meratakan vektor jarak 2 dimensi (Δx, Δy) dan data vektor tinggi (Δh) secara terpisah. Berdasarkan penelitian yang dilakukan, diperoleh bahwa ketelitian rata-rata posisi horisontal dari hitung perataan secara simultan dan bertahap pada kasus jaring kuadrilateral relatif sama, namun untuk ketelitian posisi vertikal memberikan hasil yang berbeda. Ketelitian rata-rata posisi vertikal yang dihasilkan dari hitung perataan secara bertahap lebih teliti dibandingkan dengan hitung perataan secara simultan.Kata kunci : Perataan jaring GPS, hitung perataan secara simultan, hitung perataan secara bertahap, vektor jarak, ketelitian posisi horisontal, ketelitian posisi vertikalABSTRACTTechnically, network adjustment computations of GPS survey data can be done in two ways: adjustment computations by simultaneous and iteration. Adjustment computations by simultaneous is done by adjust of distance vector 3-dimensional (Δx, Δy, Δz) simultaneously. Adjustment computations by iteration is done by adjust of distance vector two dimensional (Δx, Δy) and high vector data (Δh) separately. Based on the research, obtained an average accuracy of horizontal position by means simultaneous and iteration are relatively same in case kuadrilateral nets, but for the vertical position accuracy is different. Accuracy of average vertical position which is derived from adjustment computations by iteration more accurate than adjustment computations by simultaneous.Keywords: GPS network adjustment, adjustment computations by simultaneous, adjustment by iteration, vector distance, horizontal position, vertical position accuracy
Analisis Penentuan Posisi GPS BAKO Dikaitkan dengan Adanya Perubahan Ionosfer yang Dihitung Berdasarkan TEC GISTM Pontianak Marlia, Dessi
REKA GEOMATIKA Vol 1, No 1 (2013)
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/jrg.v1i1.244

Abstract

Abstrak Propagasi sinyal GPS dipengaruhi oleh Total Electron Content (TEC) pada ionosfer, dimana ionosfer dipengaruhi oleh aktivitas matahari. Tujuan penelitian ini adalah  menganalisis perubahan aktivitas maksimum matahari dan dampaknya terhadap ionosfer dan melihat ketelitian pengukuran posisi GPS. Pengamatan TEC dilakukan menggunakan penerima GPS yaitu GISTM Pontianak (-0.06° LS dan 109.4° BT) pada kondisi ionosfer tenang dan terganggu akibat adanya flare dan CME yang mengakibatkan badai geomagnetik dan data GPS BAKO yang merupakan hasil pengamatan di stasiun Cibinong. Hasil dan analisis menggunakan metode statistika sederhana. Badai geomagnetik yang terjadi pada tanggal 9 Maret 2012 pada jam 09.00 UT, dengan indeks Dst -133 nT menunjukkan terjadi peningkatan nilai VTEC harian sebesar 70 TECU. Badai geomagnetik yang terjadi pada tanggal 24 April 2012, dengan indeks Dst -107 nT pada jam 05.00 UT menunjukkan peningkatan nilai VTEC harian sebesar 69 TECU. Hasil pengamatan dengan menggunakan GPS frekuensi ganda yaitu GPS BAKO Cibinong menunjukkan kesalahan posisi 2-3 kali lebih besar dibandingkan pada saat tidak terjadi badai geomagnetik. Kata kunci: GPS, ionosfer, TEC, badai geomagnetik, flare, CME. Abstract Propagation GPS signals influenced by Total Electron Content (TEC) in the ionosphere, where the ionosphere influenced by solar activity. The purpose of this research was to analyze the changes of the maximum solar activity and their impact to the ionosphere and see GPS position measurement of accuracy. TEC observations made using GPS receiver is GISTM Pontianak (-0.06 °LS and 109.4 ° BT) in the quiet and disturb ionospheric conditions due to the flare and CME cause geomagnetic storms and  GPS BAKO data which is the result on observation Cibinong station. Geomagnetic storm occurance on  9 march 2012 at 09.00 UT with Dst index -133 nT. The results and analysis using a simple statistical method, showing increasing of daily  VTEC values on 9 march 2012 up to 70 TECU. Geomagnetic storm occurance  on 24 april 2012 with Dst index -107 nT at 05.00 UT showing increasing of daily VTEC values on 24 april 2012 up to 69 TECU. The result on observation by using a dual frequency GPS BAKO Cibinong showing the error position 2-3 times greater than when geomagnetic storm does not occur. Keyword : GPS, ionosphere, TEC, geomagnetic storm, flare, CME
Membandingkan Hasil Pengukuran Beda Tinggi dari Hasil Survei GPS dan Sipat Datar -, RINALDY; ANWARI, CHAERUL
REKA GEOMATIKA Vol 1, No 2 (2013)
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/jrg.v1i2.348

Abstract

ABSTRAK Teknologi GPS diharapkan dapat mengatasi masalah penentuan posisi vertikal titik-titik di permukaan bumi terutama untuk titik-titik yang satu sama lain jaraknya relatif jauh dan saling terhalang, namun penentuan tinggi secara terestrial untuk mendapatkan data beda tinggi antar titik saat ini masih menjadi pilihan utama. Penelitian ini bertujuan membandingkan nilai beda tinggi yang diperoleh dari data tinggi hasil pengukuran survei GPS terhadap nilai beda tinggi hasil pengukuran terestrial menggunakan metode sipat datar. Dari hasil pengukuran, diperoleh rata-rata perbedaan beda tinggi GPS dan beda tinggi sipat datar yaitu 0,056 m dan rata-rata ketelitian beda tinggi sipat datar sebesar ± 0,016 m, sementara rata-rata ketelitian beda tinggi GPS sebesar ± 0,029. Hasil pengujian simpangan baku beda tinggi GPS yaitu semua simpangan baku memenuhi toleransi yang ditetapkan, sehingga beda tinggi survei GPS dapat diaplikasikan untuk keperluan titik kontrol foto udara vertikal. Besar kesalahan penutup beda tinggi sipat datar yaitu 0,015 dan besar kesalahan penutup beda tinggi GPS yaitu 0,025, dengan mengikuti ketentuan Jaring Kerangka Kontrol Vertikal (JKKV) menurut Standar Nasional Indonesia, maka kesalahan penutup beda tinggi sipat datar masuk ke dalam orde L3 dengan besar toleransi >12mm √D, sedangkan kesalahan penutup beda tinggi GPS masuk ke dalam orde L4 dengan besar toleransi >18mm √D. Kata kunci : Posisi vertikal, beda tinggi, survei GPS, sipat datar ABSTRACT GPS technology is expected to solve the problem of determining the vertical position of points on the Earth's surface, especially for the points that each other are relatively distant and blocked each other, but the determination of terrestrial measurement to get the levelling data is still the main choice. This research will compare the value of levelling data obtained by high GPS survey measurements with the value of levelling terrestrial measurements using spirit leveling. From the measurement results, an average differential value of GPS levelling and spirit levelling is 0,056 m, the average difference for the spirit levelling accuracy is ± 0,016 m and a levelling GPS is ± 0,029. Standard deviation of the test results from leveling GPS is set all tolerances, so that the leveling from GPS survey can be applied for the purposes of aerial photographs vertical control points.The value of closing error from sprit levelling and GPS, respectively amounting to 0.015 m and 0.025 m, follow the Indonesian national standard, value of closing error from spirit leveling into a L3 order with closing error tolerance is > 12mm √D, while closing error from GPS leveling into a L4 order with closing error tolerance is >18mm √D.Keywords : vertical position, levelling,GPS survey, Spirit leveling
Aplikasi Survei GPS dengan Metode Statik Singkat dalam Penentuan Koordinat Titik-Titik Kerangka Dasar Pemetaan Skala Besar RUDIANTO, BAMBANG; AZWAR, RENDY FAISAL
REKA GEOMATIKA Vol 1, No 2 (2013)
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/jrg.v1i2.491

Abstract

ABSTRAKKeberadaan kerangka dasar pemetaan sebagai titik-titik acuan dalam penentuan posisi titik-titik detail di lapangan sangat diperlukan. Penelitian ini merupakan kajian empirik aplikasi survei GPS dengan metode statik singkat dalam penentuan koordinat titik-titik kerangka dasar pada pemetaan skala besar. Penelitian ini dilakukan pada daerah dengan kondisi ruang pandang ke langit bervariasi relatif terbuka dan tertutup, pengamatan dilakukan menggunakan receiver GPS satu frekuensi dengan geometri berbentuk poligon. Berdasarkan hasil penelitian yang telah dilakukan dapat disimpulkan bahwa penentuan posisi menggunakan GPS dengan metode statik singkat dapat digunakan untuk pemetaan skala 1 : 250 dengan waktu pengamatan setiap titik 30 menit, 1 : 500 dengan waktu pengamatan 20 menit, 1 : 750 dengan waktu pengamatan setiap titik 15 menit.Kata kunci: kerangka dasar pemetaan, survei GPS, statik singkatABSTRACTThe existence of a fundamental framework for mapping a large scale as reference points in determining the position of an object is needed. This research is an empirical study of the application of GPS survey with a rapid static method in determining the coordinates of points on the fundamental framework for mapping a large scale. This research was conducted in an area with good visibility and bad visibility, observations were made using a single frequency GPS receiver, observation geometry is a polygon. Based on the research that has been done can be concluded that the use of GPS positioning with a rapid static method can be used for mapping the scale of 1: 250, 1: 500, and 1: 750 with a length of observation time each 30 minute, 20 minute, and 15 minutes.Keywords: fundamental framework for mapping, GPS surveys, rapid static
Pengaruh Koneksitas Jaring Terhadap Ketelitian Posisi Pada Survei GPS Utama, Taufan Akbar
REKA GEOMATIKA Vol 1, No 1 (2013)
Publisher : Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/jrg.v1i1.245

Abstract

ABSTRAK Secara teoritis, salah satu faktor yang mempengaruhi ketelitian posisi titik-titik dari survei GPS adalah geometri jaring, yaitu banyaknya jumlah baseline yang terikat ke suatu titik (koneksitas titik). Penelitian ini menganalisis pengaruh banyaknya koneksitas titik dalam suatu jaring terhadap ketelitian posisi yang diperoleh dari hasil pengukuran GPS menggunakan receiver HI-TARGET HD8200X Single Frequency (L1) dengan format RINEX di 6 titik dengan sebaran titik-titik berada di wilayah Itenas, Gasibu, Cukangkawung, Cikutra, Siliwangi, Antapani dan Jalan Jakarta. Metode pengukuran yang digunakan adalah metode diferensial statik dan diujikan beberapa bentuk desain jaring dengan jumlah koneksitas yang berbeda-beda. Dari hasil hitungan yang diperoleh, jaring GPS dengan koneksitas 2 dan 3 menghasilkan ketelitian posisi horizontal dan vertikal rata-rata ± 20 cm dan ± 12 cm, sedangkan untuk koneksitas 4 dan 5 ketelitian posisi horizontal dan vertikal ± 9 cm. Penggunaan koneksitas di atas 4 menunjukkan peningkatan ketelitian yang tidak berarti, artinya penggunaan jaring dengan koneksitas 4 sudah optimal. Kata kunci: ketelitian posisi, geometri jaring, koneksitas titik. ABSTRACT Theoretically, one of factor that influenced the points positioning accuracy in GPS surveying is network geometric, which is the number of the baselines that bond to a point (point connectivity). This research analyzed the influence of the number of point connectivity in a single network to the position accuracy that resulted by GPS observation using HI TARGET HD8200X Single Frequency (L1) receiver device with RINEX format. The observation was held using 6 (six) ground points that distributed in different location, those are: ITENAS, Gasibu, Cukangkawung, Cikutra, Siliwangi, Antapani, and Jakarta Street. The method that used in this research was static differential and has been examined in some different network connectivity design. According to the result of this observation, the GPS network with 2 and 3 networks connectivity give the average accuracy of horizontal and vertical position are  ± 20 centimeters and ± 12 centimeters, while with 4 and 5 networks connectivity is ± 9 centimeters. The increase of accuracy for network more than 4 connectivities is not significant. So, the use of 4 networks connectivity was the most optimal. Keywords: position accuracy, network geometry, point connectivity.

Page 4 of 10 | Total Record : 96