cover
Contact Name
Nur Hasanah
Contact Email
nur.hasanah@batan.go.id
Phone
+6221-5204243
Journal Mail Official
jpen@batan.go.id
Editorial Address
Kawasan Kantor Pusat Badan Tenaga Nuklir Nasional Jl. Kuningan Barat, Mampang Prapatan, Jakarta 12710 Kotak Pos 4390 Jakarta 12043
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Jurnal Pengembangan Energi Nuklir
ISSN : 14109816     EISSN : 25029479     DOI : https://doi.org/10.17146/jpen
Jurnal Pengembangan Energi Nuklir publishes scientific papers on the results of studies and research on nuclear energy development with the scope of energy and electricity planning, nuclear energy technology, energy economics, management of nuclear power plants, national industries that support nuclear power plants, aspects of the nuclear power plant site and environment, and topics others that support the development of nuclear energy.
Articles 343 Documents
ANALISIS GRADIENT HORIZONTAL (GRAVITI) UNTUK KONFIRMASI AWAL SESAR PERMUKAAN DI TAPAK BANTEN Hadi Suntoko; Ari Nugroho
Jurnal Pengembangan Energi Nuklir Vol 13, No 2 (2011): Desember 2011
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2011.13.2.1464

Abstract

ABSTRAKANALISIS GRADIENT HORIZONTAL (GRAVITI) UNTUK KONFIRMASI AWAL SESAR PERMUKAAN DI TAPAK POTENSIAL, BANTEN. Telah dilakukan pengukuran gaya berat di sekitar tapak potensial Banten untuk Pembangkit Listrik Tenaga Nuklir (PLTN) yang teridentifikasi adanya sesar permukaan dalam radius 25 km pada batuan endapan Gunungapi Gede Salak. Penelitian dilakukan dengan sistim grid (1500 m dan 500 m), memerlukan 217 titik pengukuran dengan tujuan untuk menambah database dan memverifikasi keberadaan sesar teridentifikasi Margosari yang berarah barat-timur, Banten-1 berarah utara-selatan, Bojonegara-1 dan Bojonegara-2 berarah barat laut-tenggara serta kelurusan-kelurusan lainnya. Penelitian menggunakan Metode gradient horizontal (graviti) yang didasarkan pada variasi medan gaya berat di permukaan bumi terutama menginterpretasi perubahan terhadap respon batuan di sekitarnya untuk menentukan batas kontras lateral densitas yang dapat memberikan identifikasi awal kondisi batuan yang tersesarkan. Interpretasi dan identifikasi dari analisis data graviti memberikan keterangan awal adanya anomali perubahan terhadap nilai kontras batuan secara horizontal yang menggambarkan sumber dangkal maupun sumber dalam yang menjelaskan keberadaan sesar di sekitar tapak. Hasil analisis menunjukkan bahwa peta anomali gradient horizontal menggambarkan nilai tertinggi pada bagian tengah dan nilai rendah di bagian barat tenggara dan sesar Margosari lebih indikatif dibanding sesar Bojonegara 1 dan Bojonegara 2. Namun demikian metode ini belum dapat secara tegas menginterpretasikan keberadaan sesar di tapak Banten dengan grid yang ada.Kata Kunci: Pembangkit Listrik Tenaga Nuklir, Sesar Perumukaan, Gradient Horizontal ABSTRACTHORIZONTAL GRADIENT ANALYSIS FOR PRELIMINARY CONFIRMATION OF SURFACE FAULTING IN THE BANTEN POTENTIAL SITE. The Gravity measurements have been performed on the Banten potential site to Nuclear Power Plant with identification of surface faulting within a radius of 25 kilometers over the volcanic deposits of Gede Salak Volcano. The study was conducted with a grid system (1500 m and 500 m) in as many as 217 points with aim to increaese the database and verify the existence of Margosarifault with east-west trend, Banten-1 fault with north-south trend, Bojonegara-1 and Bojonegara-2 faults with northwest-southeast trend. The study using the horizontal gradient method based on the gravity field variations on the earth's surface. Interpretation of changes in the response of surrounding rock is a way to determine the lateral density contrast that can figure out the faulted rock conditions. One of the advantages of this method is to get the preliminary based interpretation which describes changes in the density of horizontal shallow and deep sources. On the other hand, the weakness of this method is not yet able to of define the fault based on the gradation density value changes. The analysis shows that the anomaly maps provide the highest value in the middle, low at value in the west and southeast, which give stronger indicative interpretation of Margosarifault compared to the existing Bojonegara 1 and Bojonegara 2 faults. However, this method has not been able to unequivocally interpret the presence of faults in the footprint of Banten with the existing grid.Keyword: Nuclear Power Plant, Surface Fault, Gradient Horizontal
THE EXTERNALITY STUDY OF INDONESIA NUCLEAR POWER PLANT Arief Heru Kuncoro; Tosi Prastiadi; Mochamad Nasrullah
Jurnal Pengembangan Energi Nuklir Vol 4, No 2 (2002): Desember 2002
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2002.4.2.2047

Abstract

ABSTRACT THE EXTERNALITY STUDY OF INDONESIA NUCLEAR POWER PLANT. It has been calculated the externality cost of Nuclear Power Plant on Muria Peninsula, Jepara, Central Java. In this study is used the KSN-1000 (the Korean Standard Nuclear, Pressured Water Reactor 1000 MWe) as reference. Meanwhile, for environmental data, it is used the data from Tricastin nuclear power plant. NukPacts Model is used in this study to calculate and evaluate the externality cost of nuclear power plant. The externality study consider valuing the human health effects of routine atmospheric releases from nuclear power plant and the external costs of nuclear accidents. The valuation of health effect in the externality study is carried out by a Value of Life Year Lost (VLYL) approach. The impact of routine atmospheric releases is about US$ 5.60E-05 per-kWh. Meanwhile, external cost from nuclear accident, nuclear water impact and radioactive waste disposal are expressed in US$ 2.69E-06 per-kWh, US$ 6.11E-09 per- kWh and US$ 2.54E-06 per-kWh respectively. So, the total externality cost (total damage cost) of NPP (1000 Mwe) is around US$ 6.12E-05 per-kWh.   ABSTRAK STUDI EKSTERNALITAS PEMBANGKITAN LISTRIK TENAGA NUKLIR Dl INDONESIA. Telah dilakukan perhitungan biaya ekstemalitas Pembangkit Listrik Tenaga Nuklir di Semenanjung Muria, Jepara, Jawa Tengah. Dalam studi ini digunakan referensi pembangkit nuklir Korea jenis Pressurized Water Reactor dengan daya 1000 MWe (KSN-1000), sedangkan untuk data lingkungan, digunakan referensi pembangkit nuklir Tricastin. Perangkat lunak yang dipakai untuk perhitungan dan evaluasi biaya kerusakan lingkungan akibat pembangkit nuklir adalah Program NukPacts. Studi yang dilakukan mempertimbangkan penilaian efek kesehatan manusia akibat operasi rutin PLTN dan biaya eksternal akibat kecelakaan nuklir. Penilaian terhadap dampak kesehatan dalam studi ekstemalitas digunakan pendekatan Value of Life Year Lost (VLYL). Hasil perhitungan biaya ekstemalitas akibat emisi dari operasi rutin PLTN ke atmosfer adalah sekitar US$ 5.60E-05 per-kWh, sedangkan biaya eksternalitas akibat kecelakaan nuklir, akibat dampak lingkungan melalui air dan penyimpanan limbah radioaktif, masing-masing adalah US$ 2.69E-06 per-kWh, US$ 6.11E-09 per-kWh and US$ 2.54E-06 per-kWh. Jadi total biaya ekstemalitas (total biaya kerusakan) akibat PLTN berdaya 1000 Mwe adalah sekitar US$ 6.12E-05 per-kWh.
Unjuk Kerja Pengangkutan Penumatik Sistem Small Adsober Sphere Shutdown System untuk Sistem Pemadaman Kedua RDE Denissa Beauty Syahna; Dedy - Priambodo; Guntur Eko Putro
Jurnal Pengembangan Energi Nuklir Vol 20, No 2 (2018): Desember 2018
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2018.20.2.5030

Abstract

UNJUK KERJA PENGANGKUTAN PENUMATIK SISTEM SMALL ADSOBER SPHERE SHUTDOWN SYSTEM UNTUK SISTEM PEMADAMAN KEDUA RDE. Reaktor Daya Eksperimental (RDE) adalah reaktor berbendingin gas temperatur tinggi yang merupakan program unggulan BATAN untuk mempromosikan penggunaan energi nuklir, meningkatkan penerimaan masyarakat terhadap energi nuklir, membuktian kehandalan system keselamatan dari teknologi reaktor maju, menguasaan teknologi reaktor generasi IV dan mendorong kemampuan industri nuklir nasional. RDE menggunakan Small Adsorber Sphere Shutdown system (SAS) sebagai system kedua pemadaman reaktor. SAS terdiri atas elemen SAS (B4C) 5mm sebanyak 270.000 buah,  sistem pengangkutan penumatik dan bejana penyimpanan elemen SAS. Studi ini bertujuan untuk mengetahui unjuk kerja sistem pengangkutan penumatik elemen SAS dengan parameter yang ditinjau adalah target waktu pengangkutan sebesar 100, 120, 140, 160, 180 dan 200 detik serta diameter pipa pengangkutan sebesar 40mm, 50mm, dan 60mm. Dari studi diketahui bahwa penurunan tekanan terbesar terjadi pada diameter pipa 40mm dan target waktu pengangkutan elemen SAS 100 detik yaitu sebesar 2.3psi; sedangkan penurunan tekanan terendah diperoleh pada diameter 60mm dan target waktu pengangkutan elemen SAS 200 detik yaitu sebesar 0.7 psi.Kata kunci: Unjuk kerja, pneumatik, SAS, RDE, Diameter, waktu-pengangkutan
PERHITUNGAN PARAMETER DEPOSISI LEPASAN PRODUK FISI DI PERMUKAAN TANAH TAPAK PLTN Pande Made Udiyani
Jurnal Pengembangan Energi Nuklir Vol 15, No 1 (2013): Juni 2013
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2013.15.1.1617

Abstract

ABSTRAK PERHITUNGAN PARAMETER DEPOSISI LEPASAN PRODUK FISI DI PERMUKAAN TANAH TAPAK PLTN. Deposisi adalah satu parameter  penting yang digunakan untuk kajian konsekuensi radiasi, terutama untuk menentukan aktivitas deposisi produk fisi di permukaan tanah. Aktivitas deposisi diperlukan untuk menentukan penerimaan dosis radiasi dari paparan permukaan dari groundshine dan ingestion. Tujuan penelitian adalah mengetahui parameter deposisi produk fisi dari kecelakaan AP-1000 di permukaan tanah tapak PLTN. Tapak yang disimulasikan adalah Tapak Ujung Watu, Bojonegara, dan Bangka. Selain itu untuk mendapatkan faktor-faktor yang mempengaruhi parameter deposisi. Metode perhitungan menggunakan Modul deposisition Concern dari PC Cosyma, dengan input data: source term dengan skenario kecelakaan AP-1000, data meteorologi dan kontur  tapak. Hasil penelitian menunjukkan bahwa parameter deposisi untuk tapak Bangka lebih besar dibandingkan tapak lainnya. Parameter deposisi dipengaruhi oleh kondisi meteorologi seperti stabilitas cuaca, kecepatan angin, dan curah hujan. Selain itu dipengaruhi juga oleh kekasaran permukaan kontur tapak, ketinggian lepasan produk fisi di atmosfir dan jarak  dari reaktor. Parameter deposisi tidak dipengaruhi oleh besarnya source term, tetapi dipengaruhi oleh jenis dan sifat radionuklida produk fisi Kata kunci: Deposisi, produk fisi, tanah, tapak, PLTN ABSTRACT THE CALCULATION OF DEPOSITION PARAMETER FOR FISSION PRODUCT IN SURFACE SOIL OF NPP SITE. Deposition parameter is one of the important parameters for the consequences of radiation. Primarily to determine the activity of fission product deposition on the ground surface. Deposition activity is needed to determine the radiation dose acceptance of surface exposure and ingestion of groundshine. The purpose of this study was to determine the parameters of the fission product deposition of AP-1000 accident in the NPP ground surface. The simulation has done at site of Ujung Watu, Bojonegara, and Bangka. This study is also to obtain the factors that affect the deposition parameters. Calculation method is to use a module deposisition Concern of Pc Cosyma with input data: the source term of AP-1000 accident scenario, meteorological data and the roughnes contour of site. The results showed that the deposition parameters for the Bangka is bigger than the other site. Deposition parameters are influenced by meteorological conditions such as: the weather stability, wind speed and precipitation, also by the surface roughness of site contour, height fission product releases in the atmosphere and the distance from the reactor. Deposition parameters are not affected by the magnitude of the source term, but  influenced by the type and nature of fission product radionuclides. Keywords: Deposition, fission product, soil, site, NPP
THE DEBRIS PARTICLES ANALYSIS OF RSG GAS COOLANT TO ANTICIPATE SEDIMENT INDUCED CORROSION Sriyono Sriyono; Rahayu Kusumastuti; Sofia Loren Butarbutar; Abdul Hafid; Geni Rina Sunaryo; Diyah E. Lestari; Elisabeth Ratnawati
Jurnal Pengembangan Energi Nuklir Vol 18, No 1 (2016): Juni 2016
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2016.18.1.2675

Abstract

THE DEBRIS PARTICLES ANALYSIS OF RSG-GAS COOLANT TO ANTICIPATE SEDIMENT-INDUCED CORROSION. The reliability of the structures, systems and components (SSC) of the G.A. Siwabessy Multipurpose Research Reactor (RSG-GAS) should be maintained to keep the reactor operates safely. Chemical control and management of coolant is one factor which determines the SSC’s reliability. The debris sedimentation in the primary coolant system must be examined. Debris occurs in the reactor pool, originating from airborne dust from the engineering hall. Several elements contained by the sediment can induce corrosion. This research was conducted to identify the trace elements which were contained in the sediments and determine their concentrations. The objective was to anticipate the occurrence of galvanic and pitting corrosion due to the presence of elements which are more noble than aluminum. The measurement methodology is Neutron Activation Analysis (NAA). Two groups of samples were analyzed; the first group was sampled from the debris trapped in the mechanical filter after the resin column, or known as the resin trap, and second was sampled from the debris which adhered to the heat exchanger tube. The primary coolant debris analysis showed that the neutron-activated sediment contained Na-24, Na-25, Al-28, Mg-27, Cr-51, Mn-54, Mn-56, Co-58, Co-60, Ni-65, and Fe-59. The Mn, Cr, Co, Ni, and Fe are more noble than aluminum can induce galvanic corrosion while Na, Ba, Al, and Mg are not. The radionuclides contained by the result of neutron activation of sediment from the heat exchanger tube are Mn-56, Na-24, As-76, Br-82, Fe-59, Zn-65, Cr-51, La-140, and Sc-46 which are mostly carbon steel corrosion products. Those elements do not initiate galvanic corrosion. The prevention of galvanic corrosion can be done by periodic maintenance.Key Words : sediment, debris, corrosion, galvanic, pitting, RSG Gas  
GAS C02 DAN POLUTAN RADIOAKTIF DARI PLTU BATUBARA Ida Nuryatin Finahari; Djati Hoesen Salimy; Heni Susiati
Jurnal Pengembangan Energi Nuklir Vol 9, No 1 (2007): Juni 2007
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2007.9.1.1945

Abstract

ABSTRAK EMISI GAS C02 DAN POLUTAN RADIOAKTIF DARI PLTU BATUBARA. Kebutuhan energi di Indonesia untuk pembangkit listrik masih sangat bergantung pada pembakaran bahan bakar fosil seperti batubara, minyak bumi dan gas. Pembakaran langsung batubara akan dihasifkan gas C02 yang dapat menimbulkan pencemaran udara, serta polutan radioaktif yang dapat meningkatkan paparan radioaktivitas alam. Radionuklida alam yang terkandung dalam batubara berupa kalium, uranium, thorium, dan produk- produk peluruhannya. Emisi gas C02 yang dihasilkan dari PLTU batubara dapat direduksi jumlahnya dengan melengkapi unit pembangkit dengan fasilitas pengolahan gas buang. Pada fasilitas ini, gas C02 direaksikan dengan kalsium hidroksida dan dihasilkan kalsium karbonat. Kalsium karbonat dapat dipakai sebagai bahan dasar pada industri makanan, farmasi dan industri konstruksi. Alternatif yang lain untuk mengurangi dampak pencemaran udara adalah dengan mengganti bahan bakar batubara dengan bahan bakar nuklir atau bahan bakar baru & terbarukan. Kata Kunci: Polutan radioaktif, gas C02, PLTU Batubara   ABSTRACT EMISSION OF C02 GAS AND RADIOACTIVE POLLUTANT FROM COAL FIRED POWER PLANT. Energy utilization for power plant in Indonesia is still depending on burning fossil fuel such as coal, oil and gaseous fuel. The direct burning of coal produces C02 gas that can cause air pollution, and radioactive pollutant that can increase natural radioactive dosage. Natural radionuclide contained in coal is in the form of kalium, uranium, thorium and their decay products. The amount of C02 gas emission produced by coal fired power plant can be reduced by equipping the plant with waste-gas treatment facility. At this facility, C02 gas is reacted with calcium hydroxide producing calcium carbonate. Calcium carbonate then can be used as basic material in food, pharmaceutical and construction industries. The alternative method to reduce impact of air pollution is by replacing coal fuel with nuclear fuel or new and renewable fuel. Keywords: Radioactive pollutant, C02 gas, Coal Fired Power Plant
Perbandingan Keekonomian Transmisi HVDC dan Pengangkutan Batubara Dalam Pengembangan Kelistrikan Kalimantan - Sulawesi Edwaren Liun
Jurnal Pengembangan Energi Nuklir Vol 18, No 2 (2016): Desember 2016
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2016.18.2.3167

Abstract

Sehubungan dengan karakteristik beban pada banyak wilayah di Indonesia, sistem kelistrikan sering tidak efisien. Di daerah yang jauh dari jaringan interkoneksi dan pulau terpencil misalnya, pemilihan jenis pembangkit berbahanbakar murah seperti batubara tidak tidak dapat diterapkan, sedangkanpembangkit berbahanbakar minyak biayanya sangat tinggi dan memberatkan beban subsidi. Akibatnya daerah tersebut tetap menggunakan pembangkit berbahanbakar minyak dengan membatasi waktu nyala pembangkit dan konsumen tidak mendapat layanan memuaskan. Makalah ini bertujuan untuk menganalisis sejauh mana kemanfaatan sistem transmisi HVDC dari Kalimantan ke Sulawesi sehingga konsumen mendapat layanan lebih baik dan dapat berproduksi untuk meningkatkan kesejahteraan. Metode yang digunakan dalam analisis ini adalah penelusuran pustaka dan melakukan perhitungan berdasarkan formula yang ada. Hasil yang diperoleh bahwa segi biaya langsung, sistem HVDC yang meliputi biaya saluran transmisi, konverter dan rugi-rugi daya berkisar antara 0,46 – 0,60 USD¢/kWh untuk kapasitas daya berkisar antara 500 – 2000 MWe. Sedangkan biaya angkut batubara berkisar antara 0,544 – 0,645 USD ¢/kWh untuk tongkang berukuran panjang antara 270 – 330 feet. Dengan demikian, untuk wilayah Indonesia dengan banyak pulau dan daerah terpencil memungkinkan secara lebih ekonomis untuk menyalurkan listrik dengan transmisi HVDC dari pulau atau daerah yang sistem listriknya telah berkembang, sehingga wilayah terpencil juga mendapat layanan listrik yang prima untuk meningkatkan kesejahteraan dan pendapatan penduduknya.
PERTIMBANGAN TEKNO-EKONOMI DALAM PERENCANAAN SISTEM PEMBANGKITAN Edwaren Liun
Jurnal Pengembangan Energi Nuklir Vol 1, No 1 (1999): Maret 1999
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.1999.1.1.1996

Abstract

ABSTRAK Sistem pembangkitan mempunyai aspek keandalan dan ekonomi yang sangat penting untuk dipertimbangkan. Kedua aspek sangat terkait dengan masalah teknik dan biaya yang harus dikelola, dan mengandung konsekuensi yang bersifat finansial. Daya saing ekonomi dari suatu jenis unit pembangkit maupun efisiensi sistem secara keseluruhan sangat terpengaruh oleh kecermatan pengaturannya didalam sistem. Masing-masing unit didalam sistem mempunyai karakteristik kinerja dan aspek biaya produksi energi yang berbeda, sehingga harus ditempatkan pada posisi pembebanan dan durasi tertentu di dalam sistem.   ABSTRACT Generating system have reliability and economic aspect of important consideration. Both aspects are closely related with the managed technical problems and the cost, and having a consequence of transitional nature. Economic competitiveness of a certain plant unit and also the overall system efficiency are much affected by the management inside the system. Each unit inside the system has different aspects of performance characteristic and energy production cost in such a way that the unit should be positioned at a certain loading and duration in the system.
Hal Belakang JPEN 2009 Volume 11 Nomor 1 Juni Hal Belakang
Jurnal Pengembangan Energi Nuklir Vol 11, No 1 (2009): Juni 2009
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2009.11.1.3437

Abstract

ANALISIS PENGARUH TINGKAT KOMPONEN DALAM NEGERI TERHADAP KEEKONOMIAN PLTN Sriyana Sriyana; Sahala Maruli Lumbanraja; Priyanto Mudo Joyosukarto; Imam Bastori; Yuliastuti Yuliastuti; Bambang Suprawoto; Refrison Refrison
Jurnal Pengembangan Energi Nuklir Vol 12, No 2 (2010): Desember 2010
Publisher : Pusat Kajian Sistem Energi Nuklir, Badan Tenaga Nuklir Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jpen.2010.12.2.1455

Abstract

ABSTRAKANALISIS PENGARUH TINGKAT KOMPONEN DALAM NEGERI TERHADAP KEEKONOMIAN PLTN. Telah dilakukan studi pengaruh tingkat komponen dalam negeri terhadap keenomian PLTN. Lingkup penelitian ini meliputi telaah teknologi sistem PLTN (Optimized Power Reactor, OPR-1000), kemampuan industri nasional untuk berpartisipasi dalam pembangunan PLTN dan analisis pengaruh keekonomiannya. Analisis ekonomi dilakukan untuk pembangunan 2 unit PLTN OPR-1000. Dari hasil studi dapat disimpulkan bahwa: (1) TKDN untuk pembangunan PLTN Indonesia yang pertama adalah sebesar 35,24% untuk kasus pesimis dan 43,86% untuk kasus optimis. (2) Pemenuhan angka TKDN tersebut perlu didukung pemerintah berupa kebijakan industri, terutama yang terkait dengan proses alih teknologi. (3) Besarnya biaya pembangkitan yang dapat dihemat per tahun pada penerapan TKDN pesimis berkisar antara US$ 14,55 juta - US$ 14,57 juta dan pada TKDN optimis berkisar antara US$ 22,23 juta - US$ 22,26 juta. (4) Penerapan TKDN memberikan dampak penurunan biaya pembangkitan listrik berkisar antara 1,75% - 1,76% untuk kasus pesimis dan 2,67% - 2,68% untuk kasus optimis.Kata kunci: komponen dalam negeri, keekonomian, PLTN, alih teknologi ABSTRACTANALYSIS ON THE EFFECT OF LOCAL CONTENT TO THE ECONOMIC ASPECT OF NPP. Study analysis on the effect of local content to the economic aspect of NPP has already been conducted. This scope of study covers: NPP technology system analysis (OPR-1000), national industry capability to participate in NPP construction and effect analysis toward the economic. Economic analysis is conducted for 2 units NPP OPR-1000. This study concludes that: (1) The level of local content for the first 2 units NPP in Indonesia about 35,34% (pessimistic case) and 43,38% (optimistic case). (2) To reach the local content government support is needed, i.e. policy of industry, particularly the police related to technology transfer. (3) The total generation cost that could be saved per year in pessimistic case is around US$ 14.55 million - US$ 14.57 million and in optimistic case it is around US$ 22.23 million – US$ 22.26 million. (4) The local content implementation will provide decreasing of generation cost about 1.75% up to 1.76% in pessimistic case, and around 2.67% up to 2.68% in optimistic case.Keywords: local content, economic, NPP, technology transfer

Filter by Year

1999 2021


Filter By Issues
All Issue Vol 23, No 2 (2021): Desember 2021 Vol 23, No 1 (2021): Juni 2021 Vol 22, No 2 (2020): Desember 2020 Vol 22, No 1 (2020): Juni 2020 Vol 21, No 2 (2019): Desember 2019 Vol 21, No 1 (2019): Juni 2019 Vol 20, No 2 (2018): Desember 2018 Vol 20, No 1 (2018): Juni 2018 Vol 19, No 2 (2017): Desember 2017 Vol 19, No 1 (2017): Juni 2017 Vol 18, No 2 (2016): Desember 2016 Vol 18, No 1 (2016): Juni 2016 Vol 17, No 2 (2015): Desember 2015 Vol 17, No 1 (2015): Juni 2015 Vol 16, No 2 (2014): Desember 2014 Vol 16, No 1 (2014): Juni 2014 Vol 15, No 2 (2013): Desember 2013 Vol 15, No 1 (2013): Juni 2013 Vol 14, No 2 (2012): Desember 2012 Vol 14, No 1 (2012): Juni 2012 Vol 13, No 2 (2011): Desember 2011 Vol 13, No 1 (2011): Juni 2011 Vol 12, No 2 (2010): Desember 2010 Vol 12, No 1 (2010): Juni 2010 Vol 11, No 2 (2009): Desember 2009 Vol 11, No 1 (2009): Juni 2009 Vol 10, No 2 (2008): Desember 2008 Vol 10, No 1 (2008): Juni 2008 Vol 9, No 2 (2007): Desember 2007 Vol 9, No 1 (2007): Juni 2007 Vol 8, No 2 (2006): Desember 2006 Vol 8, No 1 (2006): Juni 2006 Vol 7, No 2 (2005): Desember 2005 Vol 7, No 1 (2005): Juni 2005 Vol 6, No 2 (2004): Desember 2004 Vol 6, No 1 (2004): Juni 2004 Vol 5, No 2 (2003): Desember 2003 Vol 5, No 1 (2003): Juni 2003 Vol 4, No 2 (2002): Desember 2002 Vol 4, No 1 (2002): Juni 2002 Vol 3, No 2 (2001): Desember 2001 Vol 2, No 4 (2000): Desember 2000 Vol 2, No 3 (2000): September 2000 Vol 2, No 2 (2000): Juni 2000 Vol 2, No 1 (2000): Maret 2000 Vol 1, No 4 (1999): Desember 1999 Vol 1, No 3 (1999): September 1999 Vol 1, No 1 (1999): Maret 1999 More Issue