cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota bandar lampung,
Lampung
INDONESIA
Jurnal Rekayasa Sipil dan Desain
Published by Universitas Lampung
ISSN : 23030011     EISSN : 27150690     DOI : -
Core Subject : Engineering,
Arjuna Subject : -
Articles 15 Documents
Search results for , issue "Vol 3, No 3 (2015): Edisi September 2015" : 15 Documents clear
Studi Kolam Retensi sebagai Upaya Pengendalian Banjir Sungai Way Simpur Kelurahan Palapa Kecamatan Tanjung Karang Pusat Florince Florince; Nur Arifaini; Idharmahadi Adha
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Flood is one of the natural phenomena that cause huge losses. Population growth led to the needor increased settlements and land use changes. Rain water infiltration is reduced not only causingfloods but also droughts. Therefore, it is necessary to do environmental insightful flood control,such as retention pond. This research aims to plan and analyze the effect of making retention pondfor flood control.This research was conducted in Duana Street, Palapa Urban Village, Tanjung Karang PusatDistrict which is flowed by Way Simpur River. In this research, the hydrological analysis made ofrainfall data PH 001 Pahoman Station from 1995 to 2009. After having planned rain discharge,hydraulics analysis was executed to analyze the discharge capacity of the existing and planvolume of the storage pond. Calculations of infiltration rate were performed to calculate theabsorbed discharge. Furthermore, storage pond design plan and budget plan were made.In the analysis made, the value of planned rain discharge for 5 years return period is 5.0617m 3 /sec. Total capacity of the storage pond is 12,074.1058 m 3 . The time needed by pool fromvacant until full is 29.0202 minutes. Budget plan required in making this retention pond is Rp1,838,436,742.69. Based on the analysis performed, it was concluded that the retention pond iseffective enough to be used as one of the alternative flood control measures in urban areas.Keywords : flood, retention pond, flood control.
Studi Pengaruh Penambahan Bahan Additive TX-300 Terhadap Kuat Tekan Batu Bata Pasca Pembakaran Alhadi Pratama Bintang; Setyanto Setyanto; Idharmahadi Adha
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Along with the rise of civil construction such as housing or settlements, also increase the demandfor bricks. To be able to meet the needs of these bricks, brick production must be increased. Notonly an increase in production should be done, but the increase in terms of quantity and in termsof quality also needs to be done. One way to do is to add an additional mixture to the compositionof the brickyardIn this study used clay and additional materials TX-300 which has a variety of levels of 0.6 ml, 0.9ml, 1.2 ml and 1.5 ml with the purpose to improving the quality of the bricks, as well as comparingstrong press bricks by modifying the combustion time. Soil samples tested in this study is claywhich derived from Nyunyai street, Rajabasa, Bandar Lampung. Variations of burning time is usedfor one day, two days and three days.After doing research, from the fourth level, the compressive strength maximum average post-combustion bricks are at a level of 1.5 ml with a burning for two days. The compressive strengthvalue of 46.01 kg / cm2. This is due to the greater levels of TX-300, the greater the compressivestrength value, besides the most optimum burning time is for 2 days, this was due to theevaporation of water contained in the most optimum bricks are burning for two days.Keywords: Bricks, Clay, TX-300, Compressive Strenght
Variasi Temperatur Pencampuran Terhadap Parameter Marshall pada Campuran Lapis Aspal Beton Sarkis Enda Raya S; Priyo Pratomo; Dwi Herianto
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study was conducted to determine the effect of temperature variations on the mixing processof the asphalt concrete AC-WC (Asphalt Concrete-Wearing Course) subtle gradations in themiddle limit and lower limit of the Marshall parameters with reference to specifications of BinaMarga, 2010.From the results of experiments conducted that the optimum asphalt content is used to middle limitusing a asphalt content of 5,7% and 6,8% for the lower limit after that mixing was done usingtemperature variation of 120 o C, 130 o C, 140 o C, 150 o C, and 160 o C.To a mixture of Laston AC-WC subtle gradations middle limit grading 5,7% asphalt contentmixing temperature using a temperature of 120 o C, 130 o C, 140 o C, 150 o C, 160 o C and still meet allstandards of marshall parameters. Ideal mixing temperature variations in the middle limit ofmixing temperature 150 o C-160 o C. While the lower limit to the level of 6,8% asphalt contentmixing temperatures between 120 o C-160 o C did not meet the specifications, because the MQ valuebelow the minimum value of 250 kg / mm.Keywords: Mixing temperature, 2010 Specification, Marshall, Asphalt Concrete-Wearing Course(AC-WC) Subtle Gradation.
Analisis Joint Balok Kolom dengan Metode SNI 2847-2013 dan ACI 352R-2002 pada Hotel Serela Lampung Eddy Ristanto; Suyadi Suyadi; Laksmi Irianti
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study aimed to analyze the relationship beam-column design at Building Serela LampungHotel, which refers to SNI 2847-2013 and Methods ACI 352R-2002. In the analysis, the existingshear force on beam-column joint relationship is greater than the shear forces that are on thebeams and columns. Therefore it is necessary that the relationship between the shearreinforcement. From a review of existing columns and beam size is sufficient to carry the shearforces that occur. There are differences between the results of the review of planning method SNI2847-2013 and methods ACI 352R-2002. From the results obtained with SNI 2847-2013 shearforce to review the interior, roof interior, exterior, roof exterior, corner, and roof cornersequentially as follows: 1682.544 KN; 1380.365 KN; 607.759 KN; 364.932 KN; 607.759 KN;364.932 KN. While the method of ACI 352R-2002 as follows: 1712.750 KN; 1440.799 KN;632.642 KN; 413.498 KN; 632.642 KN; 413.498 KN. Although both methods are considered safein the planning of the object of study Serela Lampung Hotel but in general planning methods ACI352R-2002 a higher level of safety and efficiency in terms of planning method SNI 2847-2013 evengreater levels of efficiency.Keywords: SNI 2847-2013, ACI 352R-2002, joint, beams, columns, seismic load, shear force,inelastic.
Perencanaan Moda Transprtasi Umum Rute Stasiun Tanjung Karang – Bandara Radin Inten II Lampung Selatan Azizi Nazori; Dwi Heriyanto; Rahayu Sulistiyorini
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study consisted of two phases, namely collecting primary datas required, such as passengercharacteristics, choice of transport modes, flight datas, the number of passengers on certainperiod of time, distance and travel time from the Tanjung Karang Station to Radin Inten II SouthLampung Airport. Then analyze it with some methods that are used as conclusion parameters.This study uses several parameters used as reference for the planned mode of transportationplanning, i.e. the percentage of the characteristics and mode choice questionnaire results,multinomial logistic, simple linear regression, and performance planning mode of transportationof the plan.From the analysis of the datas percentage of the number of passengers with journey from BandarLampung origin who have the willingness to switch to the planned mode of transportationamounted to 96.67% or 72.75% of total passenger aircraft. The approximate number ofpassengers who will use public transport development plan based on the number of passengers 5years ie in 2019 amounted to 3,057 people per day. Planned modes of transportation wereplanned start the movement from 05.00 am to 07.00 pm with a departure time between busvulnerable for 15 minutes. As for the trip Radin Inten II Airport South Lampung - Tanjung KarangStation planned start movement from 07.00 am to 09.00 pm with a departure time of 15 minutesvulnerable. Based on the results of the processing of survey data obtained estimates of the numberof passengers in 2019 as many as 27 passengers per trip. Therefore it is required the type oftransport that meet these criteria are buses with a capacity of 35 passengers or so-called mediumbus. Performance planning public transportation based on the results of the questionnaire surveydata processing and some suggestions of passenger aircraft with the results of the servicefrequency of 4 veh / hour, 15-minute headway time, load factor of 77.14%, cycle time of 150minutes, the vehicle needs a number 12 vehicles, vehicle mileage per day amounted to 282 km,traveling speed of not more than 100 km / hour, mileage per trip of 23.5 km.Keywords: Radin Inten II Airport Lampung Selatan, Tanjung Karang Station, transportationplanning, public transportation, Performance Planning Public Transportation.
Studi Optimalisasi Fasilitas Parkir di Fakultas Keguruan Ilmu Pendidikan (FKIP) Universitas Lampung Maulana Rendri Yuda; Rahayu Sulistyorini; Dwi Herianto
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

This study consisted of two phases, which collects data required parking, such as license platenumbers of vehicles, to enter and exit the vehicle, and then analyze it with some formula that isused as a parameter conclusion. This study uses several parameters that are used as a referenceconclusion and settlement of the problem, namely the accumulation of vehicle parking, parkingindex, duration of parking, parking capacity, as well as parking turnover rate (PTO). From thecalculation results will be concluded and related solutions in that Faculty.From the analysis, the accumulated value obtained in FKIP largest car park as many as 54vehicles, while the majority of motor vehicle accumulation of 869. In calculating the capacity ofthe car park at FKIP obtained the largest parking capacity as many as 557 vehicles, while formost motor vehicle parking capacity that is equal to 6361 vehicles. In parking index calculationindex values obtained for the vehicle's biggest car park as many as 125,81%, while the largestmotor vehicle as much as 114,49%. At the turn of the calculation in the FKIP-level parking forautomobiles obtained maximum value of 3,79, while in a motor vehicle obtained maximumparking turnover rate of 3,64. From calculations conclude that the motor vehicle parking area atFKIP could not accommodate vehicle parking. As a solution to the problem of the parking lot,then made plans car and motor vehicle parking area at the FKIP plan that can accommodatevehicles parked cars on the faculties.Keywords : FKIP, parking index, parking duration , parking capacity, PTO
Studi Kuat Tekan Batu Bata Menggunakan Bahan Additive (Abu Sekam Padi, Abu Ampas Tebu dan Fly Ash) Berdasarkan Spesifikasi Standar Nasional Indonesia (SNI) Abdurrohmansyah Abdurrohmansyah; Idharmahadi Adha; Hadi Ali
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Brick is one of construction materials of building, shopping complex, real estate etc. Brick is madefrom the mixing of soil and water. In this study, the process of brick production will be tired by mixthe soil with additive materials such as rice husk ash, baggase ash and fly ash. It’s to know howbig the advantage of those additive materials and to compare the compressive strength betweenconventional brick and the brick that have mixed with rice husk ash, baggase ash and fly ash toget Indonesian National Standard for the strong and durable brick.Clay was used as the soil sample in this study. The clay is from Yoso Mulyo Village, Metro. Theadditive materials such as, rice husk ash is from Yoso Mulyo Village Metro, baggase ash is fromPT Indo Lampung Perkasa and the fly ash is from PLTU Tarahan.The result of this study show that the production of brick after burned using additive materialssuch as rice husk ash, baggase ash and fly ash, increase the compressive strength value. So, thestrength of the brick is good enough fulfilled the standard of Indonesian National StandardInstitution.Keywords: Brick, additive fly ash and rice husk ash, baggase ash, compressive strength
Studi Optimalisasi Fasilitas Parkir di Fakultas Kedokteran (FK) serta Fakultas matematika dan Ilmu Pengetahuan Alam (FMIPA) Universitas Lampung Rolan Ardeka Putra; Rahayu Sulistyorini; Syukur Sebayang
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

University of Lampung (Unila) is the only one state university in Lampung. There are severalparking areas scattered in each faculty which serves as the campus facilities. The purpose of thisstudy is to find solutions for handling the parking problems in faculty of medicine(FK) andFaculty Mathematics and Natural Sciences (FMIPA) Unila.This study consisted of two phases, which collects parking data, such as a vehicle license platenumber, time of entry and exit of vehicle, and then analyze it with some formula that is used as aparameter conclusion. Some of these parameters are accumulation of vehicle parking, parkingindex, duration of parking, parking capacity, as well as parking turnover rate (PTO).From the analysis conclude that motorcycle parking area at FK can accommodate vehicleparking. While in the existing car parking area can't accommodate parking of vehicles. Then inFMIPA motorcycle parking area can also accommodate parking of the vehicles, whereas theexisting car parking area can't accommodate the vehicles parking neatly. As a solution of theparking problem, we will make plans of car parking area at the FK that can accommodate parkingof car vehicles in both faculties.Keywords : FK, FMIPA, parking index, parking duration , parking capacity, PTO
Analisis Perhitungan Daya Dukung Pondasi Footplate dengan Menggunakan PHP script M Rizky Ismail; Setyanto Setyanto; Ahmad Zakaria
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Foundation as we know is part of construction. A purpose of this construction is to continue astructure load to the ground which can endure the load without settlement effect. In order toguarantee the building is on stable condition concerning from structure load or outer force like awind pressure, earthquake, etc and settlement which is more than permission limit unallowed. Toavoid unfunctional foundation structure, foundation must placed on the solid ground which canendure sttructure load without causing excessive settlement. In this era computer technologydevelop quickly. Part of that is programming using PHP script. Programming using script canmake some application to help us in our analyzing dan calculating proccess with interestingdesign , so we can operate it easily. And this program is using PHP script method . Basicallyanalyzing and calculating footplate manually can used up our time. Because on calculating thiswe use a complex method, we need program to analyze and calculate footplate foundation. Tomake a calculation simpler and quicker. Some of manual test result which are found by us ishaving 1% difference with the program. So we consider this program is able to calculate thefootplate foundationKeywords : foundation, footplate, PHP
Pengaruh Resin Epoksi Terhadap Mortar Polimer Ditinjau dari Kuat Tekan, Kuat Tarik Belah, Daya Serap Air dan Scanning Electron Microscope Joksan Arif; Hasti Riakara Husni; Surya Sebayang
Jurnal Rekayasa Sipil dan Desain Vol 3, No 3 (2015): Edisi September 2015
Publisher : Jurnal Rekayasa Sipil dan Desain

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Polymer mortar is a material formed through the process of building a composite concrete andbuilding polymers. Polymer mortar development efforts have been conducted in developedcountries. Until now the development of polymer mortar is still underway to reduce the use of thesemen, in order to anticipate the global warming. One of them is by using a polymer adhesivecement replacement material so produced a powerful mortal in a shorter time.On research was created mortal polymers without cement, fine aggregate and epoxy resin as thebinder of concrete. The composition of the raw materials of polymer mortar made with acomparison between aggregate and epoxy resins, with her blend of 20%, 25% .30%, 35%, 40% (%of the total weight of the aggregate). Mortar has been mold then dried in an oven at a temperatureof 600 C for 24 hours. Parameters measured include: water absorption, compressian strength,tensile strength, and microstructure analysis using a Scanning Electron Microscope (SEM). Theobservations suggest that the optimum condition of polymer mortar obtained on composition: 65%of the aggregate (aggregate) and 35% epoxy resin (% of weight of fine aggregate). In this state ofpolymer mortar characteristics obtained as follows: water absorption = 3,57%, compressianstrength = 6.80 MPa, and tensile strength = 1.75 Mpa. The microstructure of the polymer concreteanalyzed using SEM. Result showed that pore size distribution was uneven, and wisps of epoxyresin ≤ 30 μm.Keywords: compressian strength, tensile strength, water absorption, Scanning ElectronMicroscopy (SEM), polymer mortal.

Page 1 of 2 | Total Record : 15


Filter by Year

2015 2015


Filter By Issues
All Issue Vol 12, No 1 (2024): Edisi Maret 2024 Vol. 12 No. 1 (2024): Edisi Maret 2024 Vol. 11 No. 4 (2023): Edisi Desember 2023 Vol 11, No 4 (2023): Edisi Desember 2023 Vol. 11 No. 3 (2023): Edisi September 2023 Vol 11, No 3 (2023): Edisi September 2023 Vol. 11 No. 2 (2023): Edisi Juni 2023 Vol 11, No 2 (2023): Edisi Juni 2023 Vol 11, No 1 (2023): Edisi Maret 2023 Vol. 11 No. 1 (2023): Edisi Maret 2023 Vol. 10 No. 4 (2022): Edisi Desember 2022 Vol. 10 No. 3 (2022): Edisi September 2022 Vol 10, No 2 (2022): Edisi Juni 2022 Vol. 10 No. 2 (2022): Edisi Juni 2022 Vol 10, No 1 (2022): Edisi Maret 2022 Vol. 10 No. 1 (2022): Edisi Maret 2022 Vol 9, No 4 (2021): Edisi Desember 2021 Vol. 9 No. 4 (2021): Edisi Desember 2021 Vol. 9 No. 3 (2021): Edisi September 2021 Vol 9, No 3 (2021): Edisi September 2021 Vol. 9 No. 2 (2021): Edisi Juni 2021 Vol 9, No 2 (2021): Edisi Juni 2021 Vol. 9 No. 1 (2021): Edisi Maret 2021 Vol 9, No 1 (2021): Edisi Maret 2021 Vol 8, No 4 (2020): Edisi Desember 2020 Vol. 8 No. 4 (2020): Edisi Desember 2020 Vol. 8 No. 3 (2020): Edisi September 2020 Vol 8, No 3 (2020): Edisi September 2020 Vol. 8 No. 2 (2020): Edisi Juni 2020 Vol 8, No 2 (2020): Edisi Juni 2020 Vol 8, No 1 (2020): Edisi Maret 2020 Vol. 8 No. 1 (2020): Edisi Maret 2020 Vol 7, No 4 (2019): Edisi Desember 2019 Vol. 7 No. 4 (2019): Edisi Desember 2019 Vol 7, No 3 (2019): Edisi September 2019 Vol 7, No 2 (2019): Edisi Juni 2019 Vol 7, No 1 (2019): Edisi Maret 2019 Vol 6, No 4 (2018): Edisi Desember 2018 Vol 6, No 3 (2018): Edisi September 2018 Vol 6, No 2 (2018): Edisi Juni 2018 Vol 6, No 2 (2018): Edisi Juni 2018 Vol 6, No 1 (2018): Edisi Maret 2018 Vol 6, No 1 (2018): Edisi Maret 2018 Vol 5, No 4 (2017): Edisi Desember 2017 Vol 5, No 3 (2017): Edisi September 2017 Vol 5, No 3 (2017): Edisi September 2017 Vol 5, No 2 (2017): Edisi Juni 2017 Vol 5, No 1 (2017): Edisi Maret 2017 Vol 5, No 1 (2017): Edisi Maret 2017 Vol 4, No 4 (2016): Edisi Desember 2016 Vol 4, No 3 (2016): Edisi September 2016 Vol 4, No 2 (2016): Edisi Juni 2016 Vol 4, No 2 (2016): Edisi Juni 2016 Vol 4, No 1 (2016): Edisi Maret 2016 Vol 3, No 3 (2015): Edisi September 2015 Vol 3, No 2 (2015): Edisi Juni 2015 Vol 3, No 1 (2015): Edisi Maret 2015 Vol 3, No 1 (2015): Edisi Maret 2015 Vol 1, No 1 (2013): Edisi Maret 2013 More Issue