cover
Contact Name
Elisa Sesa
Contact Email
journal.gravitasi@gmail.com
Phone
+6282145918855
Journal Mail Official
journal.gravitasi@gmail.com
Editorial Address
https://bestjournal.untad.ac.id/index.php/GravitasiFisika/about/editorialTeam
Location
Kota palu,
Sulawesi tengah
INDONESIA
Gravitasi
Published by Universitas Tadulako
ISSN : 14122375     EISSN : 26544318     DOI : https://doi.org/10.22487/gravitasi.v18i2
Core Subject : Science, Social,
Journal Gravitasi e-ISSN: 2654-4318 contains writings raised from the results studies specialize physics sciences. Gravitasi Publishes two times a year, in June and December. For authors who are interested in submitting the manuscript in Word format, please register yourself. The manuscript must be original research, can be written in Indonesian or English, and not be simultaneously submitted for another journal or conference. Scope of published articles: Theoretical Physics and Computation, Advanced Materials , Biophysics and Medical Physics, Nuclear Physics, Oceanography, Geophysics, Astrophysics, Laser and Optoelectronics, Instrumentation Physics, and Energy and Environmental Physics.
Articles 5 Documents
Search results for , issue "Vol. 20 No. 1 (2021):" : 5 Documents clear
Desain Alat Terapi Fraktur Berbasis Medan Elektromagnetik: (Design of Electromagnetic Field Based Device for Fracture Therapy) Hasmia; Maskur; Lufsyi Mahmudin; Anis Nismayanti
Gravitasi Vol. 20 No. 1 (2021):
Publisher : Tadulako University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/gravitasi.v20i1.15453

Abstract

Fraktur adalah patah tulang yang disebabkan oleh trauma atau tenaga fisik. Permasalahan fraktur dapat menjadi besar jika tidak ditangani dengan baik. Untuk itu penyembuhan fraktur menggunakan Pulsed Electromagnetic Field (PEMF) menjadi salah satu solusi. Penelitian ini bertujuan merancang alat terapi fraktur berbasis medan elektromagnetik. Alat terapi fraktur yang dibuat menggunakan kumparan Helmholtz untuk menghasilkan medan magnet dengan variasi jumlah lilitan kawat 50 – 400 lilitan, variasi kuat arus 0,12 – 0,19 A, variasi jarak antara kumparan 5 – 25 cm, dan variasi diameter 19,8 cm dan 22 cm. Berdasarkan data yang diperoleh dapat membuktikan bahwa medan magnet berbanding lurus dengan arus dan jumlah lilitan namun berbanding terbalik terhadap jarak antara kumparan dan besar diameter kumparan. Hasil penelitian menunjukan bahwa nilai medan magnet 150 µT berhasil diperoleh dengan nilai arus 0,15 A, jumlah lilitan kawat sebanyak 300, jarak antara kumparan 10 cm, dan diameter kumparan helmholtz 19,8 cm.
Analisis Noise Level Hasil Citra CT-Scan Pada Phantom Kepala Dengan Variasi Tegangan Tabung Dan Ketebalan Irisan: (Noise Level Analysis of CT-Scan Image Results on Head Phantom with Variation of Tube Voltage and Slice Thickness) Listiyani, Iis Listiyani; Nismayanti, Anis; Maskur, Maskur; Kasman, Kasman; Ulum, M. Syahrul; Rahman, Abd. Rahman
Gravitasi Vol. 20 No. 1 (2021):
Publisher : Tadulako University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/gravitasi.v20i1.15517

Abstract

Telah dilakukan penelitian analisis noise level hasil citra CT-scan pada phantom dengan variasi tegangan tabung dean variasi ketebalan irisan. Penelitian ini bertujuan untuk mengetahui dan menganalisis noise level hasil citra CT-scan pada phantom kepala dengan variasi tegangan tabung dan ketebalan irisan. Evaluasi noise level harus dilakukan sehingga dapat mengurangi noise pada CT-scan dan phantom kepala air. Nilai noise level diperoleh dengan variasi tegangan tabung (80-140) kV dan ketebalan irisan (1-10) mm. Hasil noise level pada variasi tegangan tabung berkisar (0,72-2,97)%. Sedangkan noise level pada variasi ketebalan irisan berkisar (0,97-2,97)%. Hasil penelitian nilai noise level hasail CT-scan dengan variasi tegangan tabung dan ketebalan irisan maka dapat disimpulkan bahwa hasil citra ct-scan terbaik diperoleh pada tegangan tabung 120 kV dan ketebalan irisan 5 mm. kata kunci : Noise, Ct-Scan, Phantom, Data Sekunder, Tegangan Tabung, Ketebalan Irisan
Efek Variasi Konsentrasi Zat Aktivator H3PO4 Terhadap Morfologi Permukaan dan Gugus Fungsi Karbon Aktif Cangkang Kemiri: (The Effect of H3PO4 Variation on Morphology and Function Group of Activated Carbon of Hazelnut Shell) Eso, Rosliana; Luvi; Ririn
Gravitasi Vol. 20 No. 1 (2021):
Publisher : Tadulako University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/gravitasi.v20i1.15519

Abstract

Abstrak. Penelitian ini bertujuan untuk menjelaskan efek variasi konsentrasi zat aktivator H3PO4 pada karbon aktif cangkang kemiri yang di karbonisasi menggunakan reaktor pirolisis dengan temperatur 400 0C selama ±8 jam, diaktivasi secara kimia menggunakan aktivator H3PO4 dengan variasi konsentrasi 29%, 48%, 67%, 85%. Morfologi dan Gugus Fungsi dikarakterisasi menggunakan SEM-EDX dan FTIR. Hasil analisis SEM menunjukan bahwa permukaan karbon aktif cangkang kemiri mengalami pembentukan dan perbesaran pori seiring dengan tingginya konsentrasi yang digunakan yaitu sampai pada konsentrasi 67% sedangkan pada konsentrasi 85% memberikan reaksi yang berlebihan sehingga menyebabkan rusaknya struktur pori pada karbon aktif. Komposisi karbon aktif yang dihasilkan yaitu Karbon, Oksigen, Kalsium dan Fosfor. Hasil Spektrum FTIR menunjukan karbon aktif yang dihasilkan memiliki pola serapan dengan jenis ikatan O-H, C=C, C=O, C=C,C-H, dan P-OH. Dari hasil penelitian menunjukan tingginya konsentrasi H3PO4 pada karbon aktif menghasilkan nilai luas permukaan yang semakin besar seiring serta menyebabkan perubahan komposisi penyusun karbon aktif.
Analisis Kontras Digital Radiography Dengan Menggunakan ImageJ: (Analysis of Digital Radiography Contrast using ImageJ) Labania, Hosiana MD; P. Rindayani; Kasman; Abd. Rahman; S. Ulum
Gravitasi Vol. 20 No. 1 (2021):
Publisher : Tadulako University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/gravitasi.v20i1.15521

Abstract

Telah dilakukan penelitian tentang analisis kontras digital radiography dengan menggunakan ImageJ di RSUD Madani Palu. Tujuan dari penelitian ini adalah untuk mengetahui kualitas citra radiograf pada digital radiography dengan menganalis menggunakan ImageJ. Penelitian ini menggunakan koin aluminium sebagai obyek untuk memperlihatkan perbedaan derajat keabuan pada radiografi dengan focus film distance (FFD) 100 cm dan luas lapangan penyinaran 26 x 22 cm2. Kondisi penyinaran diberikan dengan faktor eksposi meliputi variasi tegangan tabung sebesar 60 kVp, 65 kVp, 70 kVp dan 75 kVp dengan arus waktunya sebesar 16 mAs, 20 mAs dan 25 mAs. Hasil penelitian menunjukkan semakin tinggi tegangan (kVp) maka nilai kontras dan SNR cenderung menurun dan sebaliknya nilai kontras dan SNR cenderung meningkat pada penggunaan arus waktu yang semakin tinggi. Kualitas citra yang optimal memiliki nilai signal to noise ratio (SNR) dan kontras yang tinggi pada tegangan 60 kVp dan arus serta waktu penyinaran 20 mAs.
Evaluasi Tingkat Kebisingan Pada SMK Darussalam Makassar: (Evaluation of Noise Level at SMK Darussalam Makassar) Hamsi, Taufik; Rauf, Nurlaela; Tahir, Dahlang
Gravitasi Vol. 20 No. 1 (2021):
Publisher : Tadulako University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/gravitasi.v20i1.15526

Abstract

Penelitian mengenai tingkat kebisingan di SMK Darussalam Makassar menggunakan alat sound level meter. Tingkat kebisingan di ukur di 5 titik. Pada penelitian ini aspek yang dianalisis adalah tingkat polusi bising dan hubungannya dengan jumlah kendaraan yang melintas di depan sekolah. Secara umum kebisingan di SMK Darussalam Makassar berada pada level dapat di terima sampai tidak dapat di terima dengan nilai berkisar 54,6 dB – 88,1 dB. Semakin kedalam letak titik pengukuran kebisingan di SMK Darussalam, maka semakin rendah pula tingkat kebisingan yang terjadi.

Page 1 of 1 | Total Record : 5