Bulletin of Electrical Engineering and Informatics
Bulletin of Electrical Engineering and Informatics ISSN: 2302-9285 is open to submission from scholars and experts in the wide areas of electrical, electronics, instrumentation, control, telecommunication, computer engineering, computer science, information technology and informatics from the global world. The journal publishes original papers in the field of electrical (power), electronics, instrumentation & control, telecommunication and computer engineering; computer science; information technology and informatics. Authors must strictly follow the guide for authors. Please read these instructions carefully and follow them strictly. In this way you will help ensure that the review and publication of your paper is as efficient and quick as possible. The editors reserve the right to reject manuscripts that are not in accordance with these instructions.
Articles
539 Documents
Reduction of Switches and DC Sources in Cascaded Multilevel Inverter
N. Devarajan;
A. Reena
Bulletin of Electrical Engineering and Informatics Vol 4, No 3: September 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (269.695 KB)
|
DOI: 10.11591/eei.v4i3.501
Harmonics and increasing number of switches and DC sources for increasing level is the major issue in the cascaded multilevel inverter for the application of medium and high voltage power system applications. In this paper several new techniques are used to reduce the switches and DC sources, which overcome the disadvantages of cascaded multilevel inverter. The THD values for various levels (seven & nine) are compared with and without PWM technique.
Adaptive Robust Control of Variable Speed Wind Turbine Generator
Ahmad Zare;
Ahmad Forouzantabar
Bulletin of Electrical Engineering and Informatics Vol 4, No 3: September 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (223.059 KB)
|
DOI: 10.11591/eei.v4i3.502
In this work we want to propose a control strategy to maximize the wind energy captured in a variable speed wind turbines, for this goal the speed of turbine should keep in optimum speed when the wind speed is changing. Many control approach has been suggested that is base on approximate models that it causes unsuitable behavior of system because of Uncertainty parameters of the system. Hence at this work we use adaptive robust control approach that it can to compensate Uncertain of the parameters and present a smooth system with maximum energy production. Numerical simulations are given to illustrate the effectiveness and validity of the proposed approach.
Word Sense Disambiguation on English Translation of Holy Quran
Sarah Abdul-Ameer Mussa;
Sabrina Tiun
Bulletin of Electrical Engineering and Informatics Vol 4, No 3: September 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (143.95 KB)
|
DOI: 10.11591/eei.v4i3.507
This article proposes a system based on the interpretation on the Quranic text that has been translated into English language using word sense disambiguation. This system is based on a combination of three traditional semantic similarity measurements, which are Wu-Palmer (WUP), Lin (LIN), and Jiang-Conrath (JCN) for word sense disambiguation on the English Al-Quran. The experiment was performed to obtain the best overall similarity score. The empirical results demonstrate that the combination of the three mentioned semantic similarity techniques obtained competitive results when compared with using individual similarity measurements.
An Optimization Model of Banking Outlets Integration Based on the Network Comprehensive Analysis
Yong Wang;
TA Zhou
Bulletin of Electrical Engineering and Informatics Vol 4, No 3: September 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (565.623 KB)
|
DOI: 10.11591/eei.v4i3.508
The distribution of real banking outlets is based on the establishment of branches according to administrative division, which is obviously not rational in distribution. Against this phenomenon, this paper first analyzes the major factors that affect the distribution of outlets. Then, based on complex network, it puts forward the distribution model of outlets. Finally, it analyzes the model. At the same time, the paper takes the banking outlets of China Construction Bank of Wuxi City, Jiangsu Province for example. It employs the model to distribute and integrate its banking outlets. As a result, the distribution after integrating is more rational than the previous distribution, which verifies the rationality of the model and the distribution method of banking outlets.
Reconfiguration with Simultaneous DG installation to Improve the Voltage Profile in Distribution Network using Harmony Search Algorithm
S Muqthiar Ali;
P Suresh Babu;
B Gurusekhar
Bulletin of Electrical Engineering and Informatics Vol 4, No 4: December 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (1053.229 KB)
|
DOI: 10.11591/eei.v4i4.509
Due to dynamic nature of loads, total system load is more than its generation capacity that makes relieving of load on the feeders not possible and hence voltage profile of the system will not be improved to the required level. In order to meet required level of load demand, Reconfiguration & DG units are integrated in distribution network to improve voltage profile, to provide reliable and uninterrupted power supply and also to achieve economic benefits such as minimum power loss, energy efficiency and load leveling. This work proposes minimization of real power losses and improvement of voltage profile using network reconfiguration in the presence of distributed generation. Generally distributed generations (DG) are preferred with objective of minimizing real power loss and improving voltage profile in distribution system. In this work A meta heuristic Harmony Search Algorithm (HSA) is used to simultaneously reconfigure and identify the optimal locations for installation of DG units in a distribution network. Sensitivity analysis is used to identify optimal locations for installation of DG units. The proposed method has tested in MATLAB for 33-bus and 69- Bus radial distribution systems at three different load levels and the analysis is presented for loss minimization.
Interleaved High Step-up DC-DC Converter with Diode-Capacitor Multiplier Cell and Ripple-Free Input Current
Mostafa Jalalian Ebrahimi;
Abbas Houshmand Viki Viki
Bulletin of Electrical Engineering and Informatics Vol 4, No 4: December 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (205.496 KB)
|
DOI: 10.11591/eei.v4i4.512
In this paper interleaving and switched-capacitor techniques are used to introduce a high step-up DC-DC converter for renewable energy systems application. The proposed converter delivers high voltage gain without utilizing transformer or excessive duty cycle and features ripple-free input current which results in lower conduction losses and decreased electromagnetic interference (EMI). Lower output capacitance is another advantage of proposed converter, leading to smaller size and lower cost. Furthermore lower voltage stress on switches allows the utilization of switches with low resistance. Simulation results verify the performance of suggested converter.
Invention into the AC Voltage Regulator with V/F Technique for Induction Motor Starting Applications
Mahesh Kollipara;
V N Srinivasa Rao Kolluru
Bulletin of Electrical Engineering and Informatics Vol 4, No 4: December 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (148.461 KB)
|
DOI: 10.11591/eei.v4i4.513
Modern electrical motors are available in many different forms with different mounting arrangements. To ensure a long life for the motor it is important to select it with correct degree of protection when operating under heavy duty conditions in a severe environment. Smooth starting is also one of major considerations to get long life and optimum efficiency. The conventional method to start an asynchronous motor with a soft starter is by reducing the voltage of the motor by varying the voltage “off time”. The “off time” could for example be controlled to achieve a desired maximum current level or a constant driving torque. Even if the voltage is reduced the fundamental frequency of the voltage is equal to the supply voltage frequency. That gives a large difference between angular speed of supply voltage and angular speed of the rotor during start. Due to the large difference in angular speed the motor flux will be low and thereby also the ability to produce torque. Instead of using the conventional control method with a reduced voltage it is possible to use a method with controlled flux similar to frequency inverters for soft-starters. As the soft-starter does not have the intermediate DC energy storage the applied voltage vector has to be directly modulated from the mains supply.
ANN Controller Design for Lime Kiln Process
Sandeep Kumar Sunori;
Pradeep Kumar Juneja
Bulletin of Electrical Engineering and Informatics Vol 4, No 4: December 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (1279.925 KB)
|
DOI: 10.11591/eei.v4i4.514
The lime kiln is a very complex multivariable process with severe non linearities, high degree of coupling and frequent disturbances. In this paper a 2x2 lime kiln process with two manipulated variables namely the fuel gas flowrate, and the percent opening of the induced draft damper and two controlled variables namely front end temperature and back end temperature has been considered. After its decoupling, artificial neural network (ANN) controllers have been designed to control the front end temperature. The performance of ANN controllers have been compared with that of conventional controllers.
Design of a Class F Power Amplifier With 60% Efficiency at 1800 MHz Frequency
Neda Babapour;
Javad Javidan
Bulletin of Electrical Engineering and Informatics Vol 4, No 4: December 2015
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.11591/eei.v4i4.515
Based on the portable systems application, it is necessary to design blocks with high efficiency to increase battery lifetime. Power amplifier is the highest power consumption block in transmitter. The proposed circuit was simulated using ADS Agilent based on 0.18 μm TSMC RF CMOS technology and supply voltage of 3.3V on transistor level. The proposed power amplifier was designed by Class F type at 1800 MHz with 60% efficiency and output powers of 30 dBm.
Effective Cable Sizing model for Building Electrical Services
M. Pratap Nair;
K. Nithiyananthan
Bulletin of Electrical Engineering and Informatics Vol 5, No 1: March 2016
Publisher : Institute of Advanced Engineering and Science
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (578.734 KB)
|
DOI: 10.11591/eei.v5i1.516
This paper mainly focuses on the sizing of electrical cables (i.e.cross-sectional area) and its accomplishment in various international standards. Cable sizing methods are at variance across international standards. For example, International Electrotechnical Commission (IEC), National Electrical Code (NEC), British Standard (BS) and Institute of Electrical and Electronics Engineers (IEEE). The basic philosophy underlying any cable sizing calculation is to develop a procedure model on cable sizing. The main objective of this research work is to develop effective cable sizing model for building services.