Analysis of Potential Alternative Energy Sources for Electricity Conservation in Yogyakarta State Finance Building Anna Nur Nazilah Chamim; Rahmat Adiprasetya Al Hasibi; Agus Jamal; Siva Aprilia; Yessi Jusman; Jeckson Jeckson
Journal of Electrical Technology UMY Vol 3, No 3 (2019): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.3360

Abstract

State Finance Building of Yogyakarta is a community service that is included in the types of buildings that consume electric energy that is large, so that often led to the power outage unexpectedly due to excessive use of electricity. This excessive use of electricity has also contributed to bill accounts for electricity from PLN which each month up to hundreds of millions of dollars. To that end, this research was undertaken that aim to be able to device that most optimal configuration in the use of solar panels and could compare the PLTS system between On-Grid and PLN in the aspect of cost and CO2 emissions.In knowing the potential of alternative energy sources, namely solar power connected to the PLN as the optimal power plant is carried out by means of conducting research in the form of knowing the intensity of the solar radiation data, data in the formĀ  of electric power load is active for 24 hours, and data rates time of outside peak load and time of peak load from PLN for State Finance Building Of Yogyakarta. Later, she did the simulation using software to help homer modeling from use of the most optimal solar panel. In the research results obtained that the potential PLTS system that are connected with the grid PLN unfit to be carried out because the cost of the initial investment to expenses during the period of operation of the system including the high value of the NPC of $970,742. However, the potential of the power plant that are appropriate for the conditions on site research solar power plant was connected to the grid PLN power plant configuration that is optimized for without using batteries, use only PV with a capacity of 91,35 kW, the converter with a capacity of 400 kW, and power grid network of PLN the system transmitted to PLTS On-Grid of 552 kW.
Detection of Cervical Cancer Based on Learning Vector Quantization and Wavelet Transform Dharmawan, Dhimas Arief; Listyalina, Latifah
Journal of Electrical Technology UMY Vol 3, No 3 (2019): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.3357

Abstract

Cervical cancer has became the common women dsease in the world. Mostly, cervical cancer has been already known lately, because it is very dificult to detect this in early stage. In this work, a computer based software using Learning Vector Quantization (LVQ) has been designed as the early cervical cancer detection aid tool. There are six methods before the detection is performed, namely preprocessing, contrast stretching, median filtering, morphology operation, image segmentation, and Wavelet Transform based feature extraction. In tihis work, 73 cervical cell images that consist of 50 normal images and 23 cancer images are used. 35 normal images and 14 cancer images are used to train the LVQ. Then, 23 normal images and 9 cancer images are used in the testing process. Our results show 88,89 % cancer image can be detected correctly (sensitivity), 100 % normal image can be detected corerctly (specificity), and 95,83 % for overall detection (accuracy).
Auditing of Power Quality on Building G5 of Universitas Muhammadiyah Yogyakarta Agus Jamal; Slamet Suripto; Rama Okta Wiyagi; Dimas Bangkit Wijayanto; Yessi Jusman; Teguh Iman Prasetyo
Journal of Electrical Technology UMY Vol 3, No 3 (2019): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.3361

Abstract

Universitas Muhammadiyah Yogyakarta, as an educational institution, indeed uses the building as a supporting facility for all activities carried out. In each of the reviews, these activities, of course, use of electrical energy, but not infrequently the electrical energy used exceeds the limits of the reasonableness of the resulting use in financial swelling. An energy audit is an activity carried out periodically to determine the amount of energy consumption, irregularities in the system, and load imbalances that cause power losses in a building. These parameters can be obtained by measuring on the SDP panel using a power quality analyzer with IEEE 59-1992 as a obtained reference to the results of the average voltage fluctuations are still within the safe limits determined by PLN items, i.e., from 198 to 231 volts. THDv is still within the safe limit under 5%, as well as for the THDi is also still within the safe limit of tolerance of 15%. As a result of harmonic disturbances and load imbalances in the building G5 in 2018, the caused losses of power losses that need to be borne by Universitas Muhammadiyah Yogyakarta in the amount of Rp 9,210,133.09.
Comparative Analysis of the Use of LED and HPS Lights in PT. Bukit Asam Hasibi, Rahmat Adiprasetya Al; Jamal, Agus; Surahmat, Indar; Hardiyanto, Tio; Jusman, Yessi; Arkan, Fardhan
Journal of Electrical Technology UMY Vol 3, No 3 (2019): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.3358

Abstract

The lamp is the main construction facility in the company that serves as a support for the activities of the economic system and mobility in the company. An analysis of the difference between the use of LED lights with HPS lamps at PT. Bukit Asam Tbk. reference is used to recommend the use of appropriate (technical) lighting equipment for industrial areas and to obtain better cumulative costs and energy savings for the company in the future. In this study using the lamp replacement method with the same lumen level comparison. The goal is that later the level of lighting produced is the same for each lamp. From the results of this study it was found that the technical use of 70W, 150W, 250W and 400W HPS lamps has an efficacy level of 84 to 123 lm / W. Whereas the 80W, 200W, 300W, 450W LED lamps are 90 lm / W and the results of the cumulative value or the total cost of operating and maintenance costs for 15 years between HPS lamps versus the LED lights that occur is that in HPS lamps the total cost incurred amounting to 20,604,230,235 rupiahs while for LED lamps it is 27,787,386,324 rupiahs which can be seen that the use of more economical lighting is HPS lamps.
Analysis of Reliability-based Systems of 20kv Distribution Network Disturbance on PT. PLN Rayon Panam Suripto, Slamet; Putra, Karisma Trinanda; Jusman, Yessi; Aroffi, Muhammad Rusydi Al; Jamaaluddin, Jamaaluddin
Journal of Electrical Technology UMY Vol 3, No 3 (2019): September
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/jet.3359

Abstract

Electricity needs for each year has increased, this is due to an increase in people's lives. Reliability is an important factor in the operation of distribution system and is an important factor in the continuity of the waiter to the consumer. Several parameters are used as reference to megukur level of reliability of a distribution system that is SAIFI (avarage interuption of frequency index system) is a calculation of the number of failures or disruptions average - average one year, SAIDI (System of interruption Duration Index) index median duration - average system interruption during the year. In this study was also performed calculations eens (Expected Energy Not Supplied) This calculation is done because of disturbance at each feeder there is energy that can not be channeled, it can happen losses. Based on the calculation and analysis that the reliability index is obtained there are some feeder Rayon Panam categorized as not reliable because it has a high SAIFI value not in accordance with the target SPLN No. 68-2 1986 and IEEE std 1366-2003. Energy losses that can not be distributed annually sizeable each feeder. This indicates a feeder located at Panam Rayon considered less reliable, to the need for repairs and maintenance