PELATIHAN PENGGUNAAN TEKNOLOGI REVERSE OSMOSIS UNTUK AIR MINUM DI KAMPUNG TUA TELUK MATA IKAN Abdul Malik Made; Suharjo Suharjo; Ridha Siddiq; Sony Liston; Rapiansyah Putra; Zikri Zikri
Jurnal Pendekar Nusantara Vol. 3 No. 2 (2026): FEBRUARI 2026
Publisher : LPPM-Universitas Batam

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37776/pend.v3i2.2108

Abstract

Ketersediaan air bersih di wilayah pesisir Indonesia masih menjadi tantangan serius akibat intrusi air laut yang menyebabkan air tanah bersifat payau. Kampung Tua Teluk Mata Ikan, Kelurahan Sambau, Kecamatan Nongsa, Batam, merupakan salah satu daerah yang terdampak, di mana air sumur masyarakat memiliki kadar salinitas tinggi (3.500–5.000 ppm) sehingga tidak layak dikonsumsi. Untuk menjawab permasalahan tersebut, kegiatan pengabdian kepada masyarakat ini dilaksanakan melalui pelatihan penggunaan dan perawatan teknologi Reverse Osmosis (RO) sebagai solusi pengolahan air payau menjadi air minum. Metode pelaksanaan menggunakan pendekatan partisipatif berbasis kebutuhan masyarakat, dengan tahapan observasi, perencanaan, pelatihan teknis, praktik langsung, serta evaluasi berbasis pre-test dan post-test. Hasil pelatihan menunjukkan peningkatan signifikan pemahaman dan keterampilan teknis masyarakat, dengan rata-rata pemahaman naik sebesar 78%. Peserta mampu merakit sistem RO 500 GPD secara mandiri, melakukan perawatan preventif, serta mengukur kualitas air melalui parameter TDS dan pH. Selain memenuhi kebutuhan air bersih, program ini juga memunculkan inisiatif masyarakat untuk mengembangkan usaha mikro berbasis pengelolaan air minum. Kesimpulannya, pelatihan RO berbasis praktik dan pendampingan intensif efektif meningkatkan literasi teknologi masyarakat sekaligus membuka peluang pemberdayaan ekonomi. Disarankan adanya pelatihan lanjutan terkait troubleshooting dan manajemen sistem, serta pembentukan kelompok kerja untuk menjaga keberlanjutan program.
Analisa Kualitas Rekondisi Pipa Collapse Astm A106 Grade B Dengan Proses Heat Treatment Normalizing Dan Quenching Pada Uji Tarik Ridha Siddiq; Abdul Hamid; Ilham Maulana
Venus: Jurnal Publikasi Rumpun Ilmu Teknik  Vol. 4 No. 5 (2026): Oktober: Venus: Jurnal Publikasi Rumpun Ilmu Teknik
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/venus.v4i5.1774

Abstract

ASTM A106 Grade B pipes that have collapsed under external pressure must be reconditioned before their fitness for further use can be reassessed. This study analyzes how normalizing and quenching heat treatments affect the mechanical properties of collapsed pipes, using tensile testing. The deformed pipes were first reconditioned and then heated to 850°C with a holding time of 1 hour. After heating, the normalized specimens were cooled slowly in open air, while the quenched specimens were cooled rapidly in water. Nine specimens were tested and divided into three groups: non-heat-treated specimens as the control, normalized specimens, and quenched specimens. The tensile test measured yield stress, ultimate tensile stress (UTS), and elongation. The non-heat-treated specimens had a yield stress of 387 MPa, a UTS of 483 MPa, and an elongation of 20%. Normalizing lowered the yield stress to 275 MPa and the UTS to 452 MPa, but raised the elongation considerably, to 37%. Quenching produced the highest strength of the three groups, with a yield stress of 545 MPa and a UTS of 889 MPa. This gain in strength came with a drop in elongation to 13%, which is lower than that of the untreated specimens. The comparison shows a trade-off between strength and ductility in the two heat treatment methods. Normalizing proved to be the most effective and safest reconditioning method, because it restored the ductility of the material to meet the minimum ASTM A106 Grade B requirement of 23% elongation. The elongation values of the non-heat-treated specimens (20%) and the quenched specimens (13%) remained below this limit.