Claim Missing Document
Check
Articles

Found 3 Documents
Search

PEMBERDAYAAN MASYARAKAT DESA PANTAI MEKAR KECAMATAN MUARA GEMBONG DALAM PENGOLAHAN AIR ASIN MENJADI AIR MINUM BERBASIS SOLAR SEL Imam Arif Rahardjo; Readysal Monantun; Parjiman
Jurnal Pengabdian Masyarakat Fakultas Teknik : Jurnal Abditek Vol. 3 No. 02 (2023): Jurnal Pengabdian Masyarakat Fakultas Teknik: Jurnal Abditek
Publisher : LPPM Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/Abditek.032.02

Abstract

Penelitian ini mengkaji pemberdayaan masyarakat Desa Pantai Mekar, Kecamatan Muara Gembong, dalam pengolahan air asin menjadi air minum berbasis solar sel. Dengan memanfaatkan teknologi solar sel, kegiatan pengabdian ini bertujuan meningkatkan akses masyarakat terhadap air bersih di daerah pesisir yang terbatas pasokan air tawarnya. Studi ini melibatkan partisipasi aktif masyarakat sepanjang tahap perencanaan, implementasi, dan pemeliharaan sistem. Metodologi penelitian melibatkan survei, wawancara, dan analisis kualitas air asin di desa tersebut. Hasilnya menunjukkan bahwa implementasi sistem pengolahan air berbasis solar sel berhasil menghasilkan air minum berkualitas tinggi dengan tingkat salinitas yang aman bagi konsumsi manusia. Partisipasi masyarakat terbukti krusial dalam keberhasilan kegiatan pengabdian ini; pelatihan dan penyuluhan membuat masyarakat mampu mengoperasikan, merawat, dan memahami pentingnya keberlanjutan sistem. Dalam kesimpulan, pemberdayaan masyarakat Desa Pantai Mekar melalui pengolahan air asin menjadi air minum berbasis solar sel bukan hanya memberikan akses terhadap air bersih, tetapi juga membangun kesadaran masyarakat terhadap pentingnya sumber daya air yang berkelanjutan. Kegiatan pengabdian ini memberikan model bagi desa-desa pesisir lainnya dalam mengatasi tantangan pasokan air bersih dengan pendekatan yang berkelanjutan dan melibatkan masyarakat secara aktif.
Comparative Study of Split Air Conditioner Performance on Pipe Length Variations in R32, R410A, and R290 Refrigerants Imam Nursyahied; Thaha Ismail Jayadinata; Alynda Natasya Putri Ardianto; Aris Sunawar; Readysal Monantun
Jurnal Konversi Energi dan Manufaktur Vol. 11 No. 2 (2026)
Publisher : Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21009/JKEM.11.2.8

Abstract

Split air conditioners are one of the most commonly used air conditioning systems due to their compact design and flexible installation. The system consists of two units connected by copper pipes as a refrigerant circulation line. This study presents a comparative analysis of the thermodynamic performance of split AC on pipe length variations using three refrigerants, R32, R410A, and R290, with a simulation approach based on CoolProp v6.4 and REFPROP v10.0 software. The length variations of the tested pipes are 15, 20, 25, and 30 m with operating conditions according to ISO 5151:2017 standards. The parameters evaluated included cooling capacity (Qe), input power (Pinput), energy efficiency ratio (EER), and pressure drop (Δp). The accuracy of both software is measured using MAPE and RMSE metrics against manual calculations as a reference. The simulation results showed that the increase in pipe length led to an average decrease in Qe of 10.3-10.4% from the 15 m to 30 m pipe length in all three refrigerants. R290 recorded the highest EER (3.87-3.48), followed by R32 (3.72-3.33), and R410A (3.36-3.01). R410A produces the largest pressure drop (25.87 kPa at 30 m), while R290 has the lowest pressure drop (12.56 kPa). Accuracy analysis showed that REFPROP was more accurate than CoolProp on all parameters with an average MAPE difference of 0.57%, although the difference between the two was relatively small. Large deviations in the Δp parameter (>168%) are due to fundamental flow model differences, not thermodynamic errors. The results of this study provide a scientific reference in the selection of the optimal refrigerant and simulation software for split air conditioning installations with varying pipe lengths.
Micro-Credential Program for Rooftop Solar PV Installation to Enhance WorkReadiness of Vocational High School Students in Renewable Energy Engineering Imam Nursyahied; Soeprijanto; Readysal Monantun; Fadly Nendra; Setiadi Dwi Wahyu Nugroho; Muhammad Rifqy Saputra; Fauzan Ferdiansyah
JISIP: Jurnal Ilmu Sosial dan Pendidikan Vol 10 No 4 (2026): JISIP (Jurnal Ilmu Sosial dan Pendidikan) (November)
Publisher : Lembaga Penelitian dan Pendidikan (LPP) Mandala

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58258/3edvsv16

Abstract

The energy transformation towards clean energy sources has driven therapid development of rooftop solar power plants (PLTS) in Indonesia,which has resulted in an increasing need for skilled workers in therenewable energy sector. However, graduates of Vocational HighSchools (SMK) majoring in renewable energy engineering still face acompetency gap with industry needs. This study aims to develop amicro-credential program for installing rooftop solar power systemsand test its effectiveness in improving the job readiness of vocationalhigh school students. Using a Research and Development (R&D)approach with the 4D model (Define, Design, Develop, Disseminate) inthe pilot study phase, the study involved 20 12th-grade students of theElectrical Power Installation Engineering Vocational High School.Evaluation was conducted through a one-group pretest-posttest designreinforced by practical assessments, a self-confidence scale, and anindustry acceptance survey. The results showed that the microcredential program was successfully developed with a 40-hourcurriculum structure covering aspects of occupational safety,mechanical and electrical installation, system testing, andtroubleshooting. The program implementation showed a significantincrease in students' technical competency with an average N-Gain of0.71 (high category), increased self-confidence, and all participantswere able to independently complete the mini solar power plantinstallation practice. An industry acceptance survey showed an averagesatisfaction level of 4.3 out of 5. The micro-credential program hasproven effective in bridging the competency gap between vocationalhigh school graduates and the needs of the renewable energy industry.Policy implications include the need to integrate micro-credentialschemes into vocational high school curricula and formal recognitionfrom industry and the government