Kajian Eksperimental Sifat Mekanik Beton Porous dengan Variasi Faktor Air Semen Desmaliana, Erma; Hazairin, Hazairin; Herbudiman, Bernardinus; Lesmana, Rossa
Jurnal Teknik Sipil Vol 15, No 1 (2018)
Publisher : Program Studi Teknik Sipil Fakultas Teknik Universitas Atma Jaya Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (573.16 KB) | DOI: 10.24002/jts.v15i1.3147

Abstract

Abstract: Porous concrete is one of the sustainable concrete technology innovations without fine aggregates and high porosity. Porous concrete could be used on road pavement to overcome the run-off water and applied as a retaining wall to minimize groundwater pressure. This study purposes to determine the mechanical properties of compressive strength, split-tensile strength, flexuralstrength and permeability of porous concrete with various water cement ratio experimentally. 10-mm-diameter and 20-mm-diameter of Batujajar split used as coarse aggregates. This study uses concrete mixture with water cement ratio variations of 0.3, 0.35, 0.4, 0.45 and 0.5 on the coarse aggregate gradation of continuous. The test specimens used three cylinders of 15x30cm for compressive and split-tensile strengths, except for permeability strength which used one cylinder of 10x20cm. Beam specimens of 15x15x60cm were used for bending strength test by third-point loading method. The tested mechanical properties are 7, 14 and 28 days compressive strengths, 28 days split-tensile strength, 28 days bending strength and 28 days permeability strength. The experimental results show that the average compressive strengths of porous concrete with variationof water cement ratio of 0.3, 0.35, 0.4, 0.45 and 0.5 for 28 days is 17.9 MPa, 16.1 MPa, 14.2 MPa, 11.2 MPa and 8.8 MPa, respectively. The average split-tensile strengths of porous concrete with variation of water cement ratio of 0.3, 0.35, 0.4, 0.45 and 0.5 for 28 days is 1.6 MPa, 1.5 MPa, 1.4 MPa, 1.2 MPa and 0.9 MPa, respectively. The average flexural strengths of porous concrete with variation of water cement ratio of 0.3, 0.35, and 0.4 for 28 days is 1.6 MPa, 1.5 MPa and 1.1 MPa, respectively. The average permeability strengths of porous concrete with variation of water cement ratio of 0.3, 0.35, 0.4, 0.45 and 0.5 for 28 days is 3.5 mm/s, 3.7 mm/s, 4.1 mm/s, 4.3 mm/s dan 5.0 mm/s, respectively. Based on the experimental study it shows that porous concrete with all variations of water cement ratio achieves the structural strength and is recommended as a pre-fabricated pavement structure material with small dimensions relatively to prevent bending cracks. Abstrak: Beton porous merupakan salah satu inovasi teknologi beton berkelanjutan tanpa agregat halus dengan porositas tinggi. Beton porous ini dapat digunakan pada perkerasan jalan untuk menanggulangi air run-off, serta dapat diaplikasikan sebagai dinding penahan tanah yang berfungsi untuk meminimalisir tekanan air tanah. Penelitian ini bermaksud untuk mengkaji secara eksperimental sifat mekanis terhadap kuat tekan, kuat tarik belah, kuat lentur dan permeabilitas beton porous dengan berbagai variasi faktor air semen. Agregat kasar yang digunakan batu pecah Batujajar berukuran 10 mm – 20 mm. Penelitian ini menggunakan campuran beton dengan variasi faktor air semen sebesar 0.3, 0.35, 0.4, 0.45, dan 0.5 pada gradasi agregat kasar menerus. Benda uji yang digunakan untuk setiap varian adalah 3 benda uji beton silinder yang berukuran 15x30 cm untuk uji kuat tekan beton dan uji kuat tarik belah beton dan 1 benda uji beton silinder 10x20 cm untuk uji permeabilitas. Benda uji balok berukuran 15x15x60 cm untuk uji kuat lentur dengan metode third point loading. Sifat mekanik yang diuji adalah kuat tekan beton pada umur 7, 14 dan 28 hari untuk uji kuat tekan beton dan 28 hari untuk kuat tarik belah beton, kuat lentur beton dan permeabilitas. Hasil eksperimen menunjukkan nilai kuat tekan beron porous dengan varian campuran faktor air semen 0.3, 0.35, 0.4, 0.45, 0.5 untuk 28 hari berturut-turut adalah 17.9 MPa, 16.1 MPa, 14.2 MPa, 11.2 MPa, dan 8.8 MPa. Nilai kuat tarik belah beton dengan varian campuran faktor air semen 0.3, 0.35, 0.4, 0.45, 0.5 untuk 28 hari berturut-turut adalah 1.6 MPa, 1.5 MPa, 1.4 MPa, 1.2 MPa, dan 0.9 MPa. Nilai kuat lentur beton dengan varian campuran faktor air semen 0.3, 0.35, 0.4 untuk 28 hari berturut-turut adalah 1.6 MPa, 1.5 MPa, 1.1 MPa. Nilaipermeabilitas beton porous dengan varian campuran faktor air semen 0.3, 0.35, 0.4, 0.45, 0.5 adalah 3.5 mm/det, 3.7 mm/det, 4.1 mm/det, 4.3 mm/det dan 5.0 mm/det. Dari hasil eksperimen menunjukkan bahwa beton porous dengan semua variasi faktor air semen mampu mencapai kekuatan struktural dan penggunaannya layak direkomendasikan sebagai material struktur perkerasan pre-fabrikasi dengan dimensi yang relatif kecil untuk menghindari retak lentur.
Studi Perbandingan Analisis Struktur Rumah 2 Lantai Menggunakan Kayu Glulam dan Kayu Solid Terhadap Beban Gempa. (Hal. 85-94) Taufik, Ramdhan; Desmaliana, Erma; Pribadi, Amatulhay
RekaRacana: Jurnal Teknil Sipil Vol 5, No 1: Maret 2019
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (745.492 KB) | DOI: 10.26760/rekaracana.v5i1.85

Abstract

ABSTRAKKondisi geografis Indonesia memiliki struktur tektonik kompleks. Kondisi ini membuat perencanaan rumah tinggal 2 (dua) lantai membutuhkan pertimbangan khusus dari segi kekuatan dan kekakuan. Penggunaan material kayu sebagai bahan konstruksi di Indonesia masih jarang digunakan. Kayu glulam adalah suatu produk kayu rekayasa yang dibuat dari beberapa bilah kayu yang direkatkan dengan arah sejajar serat menggunakan perekat berupa lem. Penelitian ini bertujuan untuk mengidentifikasi respon struktur pada rumah tinggal menggunakan material kayu glulam dan solid dengan bantuan program ETABS 2016. Berdasarkan analisis yang telah dilakukan, diperoleh nilai periode struktur, gaya geser dasar, dan simpangan antar lantai antara seluruh model menunjukan hasil yang berbeda, perbedaan diakibatkan dari hasil konversi berat jenis dan modulus of elastisity berdasarkan BS EN 1194:1999. Berdasarkan analisis non-linier pushover didapatkan bahwa kayu glulam Nyatoh (kayu kelas III) berada pada level pada kinerja B to IO (Immediate Occupancy), dimana hasil tersebut tidak berbeda jauh dengan kayu solid Bangkirai (kayu kelas I).Kata Kunci: rumah tinggal, kayu glulam, non-linier pushover ABSTRACTGeographical condition of Indonesia has a complex tectonic structure. These conditions create  2-storyhome-planning that require special consideration in terms of strength and rigidity. The use of wood as a construction material in Indonesia is still rarely used. Glulam wood is a wood products engineering made from wooden slats several glued with the direction of the parallel fibers using adhesives. This research aims to identify the structure of the response at home using basic material glulam and solid wood with the help of ETABS 2016 programs. Based on the analysis that has been done, obtained the value of the structure periode, base shear force, and interstory drift between all models show different results, the difference is due to the results of specific gravity conversion and modulus of elasticity base on BS EN 1194:1999. Based on non-linear pushover analysis, it shows that Nyatoh glulam wood (class III wood) was at the level of the B to IO (Immediate Occupancy) performance, where the results were not much different from Bangkirai solid wood (class I wood).Keywords: home livingstructure, glulam wood, non-linear pushover
Kajian Eksperimental Sifat Mekanik Panel Cross Laminated Timber Kayu Sengon dan Kayu Jabon (Hal. 78-87) Abdurrahman, Irfan Naufal; Gultom, Heru Juhdi; Desmaliana, Erma
RekaRacana: Jurnal Teknil Sipil Vol 4, No 4: Desember 2018
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (785.934 KB) | DOI: 10.26760/rekaracana.v4i4.78

Abstract

ABSTRAKPanel Cross Laminated Timber (CLT) merupakan rekayasa kayu dengan penyusunan kayu dengan arah bersilangan 90  Material kayu yang digunakan yaitu kayu Sengon dan kayu Jabon. Pembuatan panel CLT menggunakan perekat Polyvinyl Acetate, Cross-linker, dan Lateks Karet Alam dengan perbandingan 1:1 untuk base dan 15% untuk katalisator. Tujuan dari penelitian ini, untuk mengetahui kinerja panel CLT kayu Sengon dan kayu Jabon terhadap beban tekan dan geser. Pembuatan panel CLT dilakukan dengan menggunakan kempa dingin dan dimensi panel CLT yang digunakan yaitu 950mm 950mm 120mm. Hasil pengujian eksperimental pada benda uji small clear, didapatkan bahwa kayu jabon dan kayu sengon masuk kedalam kelas kuat V. Kapasitas tekan panel CLT kayu Sengon lebih kuat dibandingkan CLT Jabon yaitu 12,196 MPa dengan defleksi 10,51 mm dan kapasitas tekan panel CLT Kayu Jabon 9,572 MPa dengan defleksi 2,67. Pada pengujian kuat geser Panel CLT kayu Sengon menghasilkan nilai kuat geser lebih baik dari pada CLT kayu Jabon sebesar 0,09 MPa, dan kuat geser CLT kayu Jabon 0,089 MPa. Kata kunci: cross laminated timber, perekat, kuat tekan, kuat geser, defleksi. ABSTRACTCross Laminated Timber (CLT) Panel Is wood engineering with wood’s arrangement cross direction 90°. Wood materials used Sengon and Jabon. Making CLT panels using Polyvinyl Acetate, Cross-linker, and Natural Rubber Latex adhesives with a ratio of 1:1 for base and 15% for catalyst. The purpose of this research is to know the performance of Sengon and Jabon wood CLT panels against press and shear load. CLT panel is made by used cold press processed and the CLT panel dimensions used is 950mm 950mm 120mm. The results of small clear test object, found that Jabon wood and sengon wood were included in the strong V class.The compressive capacity of Sengon wood CLT panel is stronger than Jabon CLT which is 12.196 MPa with 10.51 mm deflection and the compressive capacity of Jabon CLT panel is 9.572 MPa with a deflection of 2.67. The shear strength testing of Sengon wood CLT Panel produces better shear strength than Jabon wood. Shear strength Sengon’s CLT is 0.089 MPa and Jabon’s CLT is 0.128 MPa.Keywords: cross laminated timber, glue, compression strength, shear strength, deflection.
Kajian Eksperimental Perilaku Lentur Balok Laminasi Lengkung dari Kayu Jabon (Hal. 12-19) Desmaliana, Erma
RekaRacana: Jurnal Teknil Sipil Vol 3, No 3: September 2017
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (541.983 KB) | DOI: 10.26760/rekaracana.v3i3.12

Abstract

ABSTRAKKayu laminasi merupakan salah satu produk kayu rekayasa berupa kayu komposit sebagai representasi yang baik dalam efisiensi penggunaan sumber daya alam yang tersedia dari HTI dan HTR. Penggunaan kayu laminasi bertujuan untuk mengatasi keterbatasan dimensi kayu untuk aplikasi komponen struktural. Pada penelitian ini dibuat balok kayu laminasi menggunakan kayu Jabon (kayu cepat tumbuh) dengan dimensi 50 mm * 50 mm * 760 mm (dengan tebal tiap lamina 5 mm) dan tinggi pelengkung 5 cm, serta variasi bentuk yaitu horizontal dan lengkung. Perekat yang digunakan yaitu perekat sintesis tipe Poly Urethane merek Excel One. Pembebanan pada balok dilakukan di atas tumpuan sederhana dengan metode one point loading. Hasil pengujian memperlihatkan kapasitas lentur balok kayu glulam lengkung dalam memikul beban maksimum meningkat sebesar 18,67% dibandingkan dengan balok kayu glulam horizontal.Kata kunci: kayu cepat tumbuh, kayu laminasi, lengkung, Jabon, HTI, HTR ABSTRACTLaminate wood is one of wood engineering products in the form of composite wood as a good representation in the efficient use of natural resources available from HTI and HTR. The use of laminated wood aims to overcome the limitations of wood dimensions for the application of structural components. In this study, laminated wooden beams using Jabon wood (fast growing tree) with dimensions of 50 mm * 50 mm * 760 mm (with a thickness of 5 mm each lamina) and 5 cm high arch and horizontal and curved shape variations. The adhesive used is Poly Urethane type synthesized adhesive of Excel One. The loading on the beam is done on a simple pedestal with one point loading method. The test results show that the flexural capacity of the arched laminated beam in carrying peak load is increased by 18.67% compared to the horisontal laminated wooden beam.Keywords: fast growing tree, laminated wood, arch, Jabon, HTI, HTR
Kajian Respon Bangunan Menggunakan Base Isolator pada Gedung Bertingkat Sistem Pracetak dan Sistem Cast in Situ. (Hal. 50-61) Ibrahim, Ardiansyah; Desmaliana, Erma; Pribadi, Amatulhay
RekaRacana: Jurnal Teknil Sipil Vol 5, No 1: Maret 2019
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (890.024 KB) | DOI: 10.26760/rekaracana.v5i1.50

Abstract

ABSTRAKIndonesia merupakan wilayah yang memiliki resiko gempa yang cukup tinggi karena terletak pada pertemuan tiga lempeng tektonik,oleh karena itu telah dikembangkan metode desain alternatif dengan tujuan untuk mengurangi resiko kerusakan bangunan akibat beban gempa yang dikenal dengan nama sistem isolasi gempa (seismic isolation).Pada bangunan ini dipasang base isolator jenis High Damping Rubber Bearing (HDRB) dengan diameter 600 mm dan tinggi 407,9 mm.Berdasarkan hasil, diperoleh bahwa penggunaan base isolator dapat memperpanjang periode struktur bangunan dua kali untuk kedua sistem, kemudian dapat mereduksi gaya geser arah X mencapai 40% dan arah Y mencapai 50% untuk kedua sistem, lalu memperkecil simpangan antar lantai dan juga membutuhkan waktu yang lebih singkat untuk mencapai faktor partisipasi modal yang diinginkan sesuai peraturan yaitu minimal 90%. Kesimpulan dari penelitian ini adalah struktur bangunan beton pracetak lebih efektif dibandingkan dengan beton cast in situ dari aspek respon struktur.Kata kunci: pracetak, cast in situ, high damping rubber bearing ABSTRACTIndonesia is prone to seismic hazard load due to its location situated on a meeting point of three tectonic plates, therefore the alternative design methods have been developed with the aim to reduce the risk of damage to buildings due to the load known as the earthquake isolation system. At one of the building analyzed in this research was provided with High Damping Rubber Bearing (HDRB) with a diameter of 600 mm and a height of 407,9 mm. Based on the results obtained, the use of base isolator can extend the period of the structure of the building twice forboth systems, reduce the shear force reached 40% in the X direction and 50% in the Y direction for both systems, and then minimize the deviation between floors of a building and also requires less time to achieve the desired modal participation factors according the regulations that is at least 90%. The conclusion of this research is that the structure of precast concrete is more effective than cast in situ concrete from the aspect of structure response.Keywords: precast, cast in situ, high damping rubber bearing
Analisis Perbandingan Kinerja Struktur Baja SRBKK Tipe Inverted-V pada Gedung Bertingkat 12, 16, dan 20 Lantai. (Hal. 65-74) Benita, Diva Rahma; Desmaliana, Erma; Pribadi, Amatulhay
RekaRacana: Jurnal Teknil Sipil Vol 5, No 4: Desember 2019
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (849.582 KB) | DOI: 10.26760/rekaracana.v5i4.65

Abstract

ABSTRAK Konstruksi baja merupakan suatu alternatif yang dapat digunakan dalam pembangunan gedung tinggi. Salah satu cara untuk memperbesar kekakuan suatu gedung dengan memasang bresing. Pada kasus ini sistem struktur baja yang digunakan yakni Sistem Rangka Bresing Konsentrik Khusus menggunakan bresing tipe Inverted-V. Dalam tugas akhir ini dilakukan perencanaan struktur baja bertingkat 12, 16 dan 20 lantai yang dimana nantinya juga dilakukan evaluasi kinerja struktur bangunan menggunakan analisis pushover untuk menentukan struktur bangunan yang paling efektif dalam perencanaan struktur menggunakan bresing Inverted-V. Dalam tugas akhir ini, didapat level kinerja struktur pada struktur baja bertingkat 12, 16 dan 20 lantai berada pada kinerja Immediate Occupancy (IO). Dari hasil-hasil analisis yang diperoleh dapat disimpulkan bahwa struktur baja bertingkat 12 lantai menggunakan bresing konsentrik tipe Inverted-V memiliki perioda struktur yang paling kecil dan berat struktur yang lebih kecil dibandingkan sistem rangka bresing struktur lainnya. Kata kunci: struktur baja, pushover, kinerja struktur ABSTRACT Steel construction is an alternative that can be used in the construction of tall buildings. One way to increase the rigidity of a building by installing the bracing. In this case the steel structure system that will be used is the Steel Special Concentrically using Inverted-V type bracing. In this thesis, steel structure planning of 12, 16 and 20-storey will be carried out, which will also evaluate the performance of the building structure using pushover analysis to determine the most effective structure in the structure planning using Inverted-V bracing. In this thesis, it obtained the level structural performance in steel structure 12, 16 and 20-storey floors are in the performance of Immediate Occupancy (IO). From the result of the analysis that was obtained, it can be concluded that the 12-storey steel structure steel structure using concentrically Inverted V-braced frames has the smallest structural period and smaller structural weights compared to other structural bracing systems. Keywords: steel structure, pushover, structure performance
Analisis Kebutuhan Pelat Injak pada Box Underpass Akibat Pengaruh Beban (Hal. 98-108) Satrio, Wibisono Bangun; Herbudiman, Bernardinus; Desmaliana, Erma
RekaRacana: Jurnal Teknil Sipil Vol 4, No 4: Desember 2018
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (763.885 KB) | DOI: 10.26760/rekaracana.v4i4.98

Abstract

ABSTRAKUnderpass merupakan suatu bangunan terowongan termasuk sarana transportasi barang dan manusia. Underpass dibangun di bawah tanah untuk menghindari daerah/kawasan rawan kemacetan. Pada kasus tertentu, kebutuhan pelat injak dapat diabaikan keberadaanya pada struktur box underpass. Analisis dilakukan dengan membandingkan perilaku struktur dengan 2 kondisi yaitu kondisi 1 pelat tanpa timbunan dan kondisi 2 pelat injak yang tertimbun oleh tanah timbunan. Analisis dilakukan dengan perangkat lunak SAP2000. Intensitas beban mengacu pada pembebanan jembatan SNI 1725:2016. Variasi panjang untuk pelat injak yang digunakan 5 m, 6 m dan 7 m, variasi tebal pelat yaitu 30 cm, 35 cm dan 40 cm, serta pengaruh jarak spring yaitu 10 cm, 20 cm dan 30 cm. Dari penelitian, lendutan yang terjadi cenderung lebih besar pada kondisi 2 karena pengaruh beban SIDL yang besar, lendutan maksimum kondisi 1 dan 2 adalah 1,148 mm dan 1,486 mm. Perbedaan momen maksimum kondisi 1 dan 2 masing-masing 422,111 kN-m dan 309,883 kN-m. Gaya geser masing-masing sebesar adalah 259,634 kN dan 583,885 kN. Gaya-gaya yang terjadi pada kondisi 1 cenderung lebih besar dari pada kondisi 2.Kata kunci: pelat injak, tanah timbunan, distribusi beban ABSTRACTUnderpass is a tunnel building for transportation of goods and people. Underpasses are built underground to avoid areas / areas prone to congestion. In certain cases, requirement of approach slab may be ignored in structure of the underpass box. Analysis was done by comparing the behavior of the structure with 2 conditions, condition 1 with plate without soil embankment and the condition 2 approach slab is covered by soil embankment. Analysis was carried out with SAP2000. Load intensity refers to SNI 1725: 2016. Variation of length for approach slab used 5 m, 6 m and 7 m, variation of plate thickness are 30 cm, 35 cm and 40 cm, and influence of spring distance are 10 cm, 20 cm and 30 cm. From the research, deflection that occurred tends to be greater in condition 2 because influence of large SIDL loads, maximum deflection conditions 1 and 2 are 1.148 mm and 1.486 mm. Difference in maximum moment in conditions 1 and 2 is 422.111 kN-m and 309.888 kN-m. Respectively shear force is 259.634 kN and 583.885 kN. The forces that occur in condition 1 tend to be greater than conditions 2.Keywords:  approach slab,  soil  embankment, load distribution. 
Kajian Teknis Waktu dan Biaya pada Perbandingan Struktur Atap Kayu dan Struktur Atap Baja Ringan. (Hal. 118-129) Aldiansyah, Muhamad; Ratnayanti, Katarina Rini; Desmaliana, Erma
RekaRacana: Jurnal Teknil Sipil Vol 5, No 1: Maret 2019
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (508.088 KB) | DOI: 10.26760/rekaracana.v5i1.118

Abstract

ABSTRAKRangka atap pada umumnya menggunakan material kayu sebagai struktur utamanya, tetapi kayu merupakan bahan yang didapatkan dari alam, jika digunakan terus menerus maka kayu akan habis. Maka dari itu produsen mencari altenatif lain yang dapat menggantikan kayu sebagai material utama membentuk struktur atap. Dibuatlah baja ringan sebagai pengganti material kayu yang semakin lama semakin langka dan juga mahal. Penelitian ini bertujuan untuk mengetahui perbandingan kekuatan, biaya, dan waktu antara struktur atap kayu dengan struktur atap baja ringan sehingga dapat dipilih struktur mana yang lebih baik dipilih. Hasil penelitian menunjukan kekuatan struktur kayu lebih baik dibandingkan dengan baja ringan, untuk berat struktur baja ringan lebih ringan sebesar 25,11%, untuk biaya baja ringan bisa menghemat 17,93% biaya, sedangkan untuk waktu pelaksanaan kayu dan baja ringan sama-sama 85 hari. penilaian total kayu mendapatkan 1,5 poin sedangkan baja ringan mendapatkan 2,5 poin, sehingga material yang baik dipilih adalah baja ringan.Kata Kunci: baja ringan, kayu, kekuatan, biaya, waktu ABSTRACTIn general, roof truss using wood as its main structure, but wood is obtained from nature, if used continuously then the wood will be runs out. Therefore manufacturers are looking for other alternatively cansubtitute wood as the main material to form the roof structure. Cold formed steel was made to substitute wood material which is getting increasingly scarce and expensive as well. This research aims to find out a comparison of strength, cost, and time between the wooden roof structure with cold formed steel roof structure so that structure can be choosen which is the better one. Research results showed the strength of the wooden structure is better compared cold formed steel, for the weight of the structure cold formed steel lighter than wood, for the cost of cold formed steel 17,93% could save costs, for the timing of the implementation of wooden and cold formed steel is same need 85 days. Assestment of total wood get 1,5 points while cold formed steel get 2,5 points, so a better material chosen is cold formed steel.Keywords: cold formed steel, wood, strength, cost, time
Kajian Perbandingan Kinerja Struktur Dinding Geser Komposit Berdasarkan Tingkatan Gedung. (Hal. 20-29) Islamy, Dimas EL; Desmaliana, Erma; Diredja, Nessa Valiantine
RekaRacana: Jurnal Teknil Sipil Vol 5, No 3: September 2019
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (564.996 KB) | DOI: 10.26760/rekaracana.v5i3.20

Abstract

ABSTRAKSalah satu metode untuk meminimalisir simpangan horizontal yang terjadi akibat gaya gempa pada struktur adalah dengan pemasangan dinding geser. Dinding geser mampu memberikan kekuatan dan kekakuan pada struktur gedung. Pada teknologi terkini, dinding geser komposit pelat baja mampu menggabungkan kelebihan dan mengkompensasi kekurangan dinding geser beton dan pelat baja.  Tujuan penelitian ini adalah untuk mengetahui efektifitas penggunaan dinding geser komposit terhadap tingkatan struktur gedung. Penelitian ini dilakukan pada tiga pemodelan struktur gedung dengan jumlah lantai yaitu 10 lantai, 20 lantai, dan 30 lantai dengan menggunakan metode respon spektrum dan analisis beban dorong. Hasil penelitian menunjukkan bahwa simpangan atap yang terjadi pada struktur dengan dinding geser lebih kecil dibandingkan struktur tanpa dinding geser. Berdasarkan analisis beban dorong, penggunaan dinding geser komposit pelat baja dengan tebal 110 mm untuk tiga pemodelan berada pada tingkatan yang sama yaitu IO (immediate Occupancy) yangmana kekuatan dan kekakuan pada gedung hampir sama dengan kondisi sebelum terjadi gempa.Kata kunci: dinding geser komposit pelat baja, respon spektrum, analisis beban dorong, simpangan horizontal ABSTRACTOne of the method to minimize the displacement of structure affected by earthquake is by using shear wall. Shear wall can influence the ductility and stiffness to the structure. On the most recent technology, composite steel plate shear wall can combining the advantages and compensate the disadvantages  of concrete and steel shear wall. This study was conducted by using three models buildings with 10 story, 20 story, and 30 story with spectrum response methods and pushover analysis. The result of this study shows that  drift’s roof on structure using shear wall is smaller than the structure without one. Based on pushover analysis, when structure using shear wall with thickness 110 mm for three models are the same level in immediate occupancy which strength and stiffness in buildings is almost the same as the condition before earthquake.Keywords: composite steel plate shear wall, respons spectrum, pushover analysis, displacement
ANALISIS KINERJA STRUKTUR BANGUNAN RUMAH TINGGAL DENGAN KAYU GLULAM MAHONI Diredja, Nessa Valiantine; Desmaliana, Erma; Prasetyo, Raca
Rekayasa Hijau : Jurnal Teknologi Ramah Lingkungan Vol 3, No 3 (2019)
Publisher : Lembaga Penelitian dan Pengabdian Masyarakat Institut Teknologi Nasional

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (699.03 KB) | DOI: 10.26760/jrh.v3i3.3431

Abstract

ABSTRAK Rumah merupakan salah satu bangunan gedung yang harus memenuhi persyaratan keselamatan. Untuk memenuhi persyaratan keselamatan tersebut maka dalam perancangannya perlu mengikuti pedoman dan standar yang berlaku. Penelitian ini menganalisis kinerja struktur bangunan rumah tinggal kayu glulam dari kayu Mahoni berdasarkan Standar Nasional Indonesia (SNI) 7973:2013 dan Eurocode menggunakan program SAP2000. Dari hasil preliminary design didapatkan dimensi balok dengan ukuran 170 x 340 mm dan kolom berukuran 300 x 400 mm untuk SNI dan balok berukuran 270mm x 550 serta kolom berukuran 450 x 600 mm untuk Eurocode. Hasil analisis program SAP2000 menunjukan bahwa kinerja struktur kedua bangunan telah memenuhi syarat ketahanan gempa yaitu perioda struktur, simpangan ijin, dan nilai minimum ragam alami struktur. Berdasarkan hasil analisis non-linier pushover didapatkan bahwa bangunan rumah tinggal termasuk dalam kategori tingkat kinerja Damage Control untuk SNI, sedangkan bangunan rumah tinggal berdasarkan Eurocode termasuk kedalam kategori tingkat kinerja Immediate Occupancy. Kata Kunci: Kayu glulam, Mahoni, SNI 7973:2013, Eurocode, Kinerja Struktur ABSTRACT Basically a house is a building that must meet safety requirements. To meet these safety requirements, in its design it is necessary to follow applicable guidelines and standards. This study analyse the structure performance of glulam residential building from Mahogany wood based on Indonesian National Standard (SNI) 7973:2013 and Eurocode using SAP2000 Program. Based on preliminary design, different dimensions of structural elements are obtained, which is beam size 170 x 340 mm and column size 300 x 400 mm for SNI and beam size 270 x 550 mm and column size 450 x 600 mm for Eurocode. SAP2000 program analysis showed that the performance of the structures of two building has met the earthquake resistance requirements such as period of structure, story drift and minimum value of modal participation ratio. Based on the result of non-linear pushover analysis, the SNI residential building were included in the Damage Control Performance level category, while Eurocode residential building were included in the category of Immediate Occupancy performance level. Keywords: Glulam wood, Mahony, SNI 7973:2013, Eurocode, Level of Performance