Journal : Jurnal EECCIS

Analisis Tegangan Sag Pada Sistem Distribusi GI Sengkaling Penyulang Pujon Menggunakan Kompensasi DVR Eko S, Arief Trisno; Wijono, Wijono; Siswojo, Bambang
Jurnal EECCIS (Electrics, Electronics, Communications, Controls, Informatics, Systems) Vol. 14 No. 2 (2020)
Publisher : Faculty of Engineering, Universitas Brawijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/jeeccis.v14i2.638

Abstract

Makalah ini mendiskusikan tentang analisis tegangan sag dalam sistem distribusi. Tegangan sag disebabkan gangguan hubung singkat 1 fasa ke tanah. Tegangan sag memberikan dampak kerusakan pada beban Pujon. Tegangan sag diatasi dengan kompensasi tegangan dari salah satu Costum Power Device paling efektif yaitu Dynamic Voltage Restorer (DVR). Metode kontrol ANN ditambahkan dalam Kontrol Hystereisis diusulkan untuk meningkatkan kinerja DVR mengkompensasi tegangan beban. Hasil simulasi menunjukan bahwa DVR mampu mengkompensasi tegangan beban terhadap tegangan sag dari gangguan hubung singkat fasa ke tanah rata-rata sebesar 98.73%, gangguan 2 fasa ke tanah rata-rata sebesar 99.07% dan gangguan 3 fasa ke tanah rata-rata sebesar 99.34%.
Design of a Decoupling Control System for pH and TDS in Hydroponics Putri, Ina Rahmawati; Siswojo, Bambang; Rusli, Mochammad
Jurnal EECCIS (Electrics, Electronics, Communications, Controls, Informatics, Systems) Vol. 20 No. 1 (2026)
Publisher : Faculty of Engineering, Universitas Brawijaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/jeeccis.v20i1.1899

Abstract

Hydroponics was a sustainable cultivation method that optimized land and water use efficiency. The stability of the nutrient solution in this system was strongly influenced by pH and Total Dissolved Solids (TDS) parameters, which were closely interrelated. Changes in pH values could affect TDS concentration, and vice versa, creating coupled dynamics that complicated precise control. This study applied a decoupling control strategy that separated interaction effects so that pH and TDS could be controlled more independently. The system was developed using a pH sensor, a TDS sensor, an Arduino Uno microcontroller, and three peristaltic pumps for adding pH up, pH down, and nutrient solutions. The results showed that the decoupling control system in simulation-maintained pH stability with a rise time of 6.04 s, a settling time of 31.04 s, an overshoot of 9.59%, and a steady-state error of 0, while TDS achieved a rise time of 84.79 s, a settling time of 161.45 s, and a steady-state error of 0.0005%. The hardware implementation demonstrated similar performance with a pH rise time of 42.62 s, a settling time of 46 s, an overshoot of 10%, a steady-state error of 0.68%, and TDS with a rise time of 62.35 s, a settling time of 91 s, an overshoot of 2.40%, and a steady-state error of 0.72%. This study proved that the decoupling method provided more optimal nutrient control performance in hydroponic systems.