Claim Missing Document
Check
Articles

Found 31 Documents
Search

ANALISIS BERKAS SINAR-X PADA PERISAI RADIASI BERBASIS POLYESTER TIMBAL ASETAT DI MURNI TEGUH MEMORIAL HOSPITAL Dabukke, Hotromasari; Aritonang, Fitler; Sijabat, Salomo
JPFT (Jurnal Pendidikan Fisika Tadulako Online) Vol. 9 No. 1 (2021): JPFT (Jurnal Pendidikan Fisika Tadulako Online)
Publisher : Universitas Tadulako

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/jpft.v9i1.792

Abstract

This research was about the effect of polyester resin as a matrix, and lead acetate as filler in the manufacture of X-ray radiation shields in order to determine its characteristics on physical, mechanical and thermal properties at Murni Teguh Memorial Hospital. Lead acetate was varied (0, 2, 4, 6, 8, and 10) wt% with variations in sample thickness of 0.5 cm, 0.75 cm, 1.0 cm, 1.25 cm and 1.50 cm. The results showed that the physical properties (density 1.9 gr/cm 3) on the composition of 10% wt lead acetate and 85% wt polyester resin with a thickness of 1.5 cm were the best results. The higher the lead acetate composition, the higher the density value is. The light transmission value of 83% was still in accordance with the ISO standard regarding lead glass. The results of the mechanical properties test (compression test 79 kg/cm3 and hardness test 38) were the best values at the composition of 85:10:5% wt with a thickness of 1.5 cm. This shows that the composition of 85:10:5% wt is the most homogeneous composition resulting in optimum mechanical properties. The results of the DSC test showed that an endothermic temperature of 85:10:5% wt with a thickness of 1.5 cm was the best with a temperature of 3770C. From all radiation shield sample tests, the composition of 85:10:5% wt has the best physical properties and mechanical properties in accordance with ISO and SNI-16-6656-2002 standards regarding lead glass.
RANCANG BANGUN SENSOR WATER LEVEL K-0135 PADA ALAT SUCTION PUMP Wardana, Chandra; Sijabat, Salomo; Abdillah, Khairil; Dabukke, Hotromasari
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 2 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v6i2.3565

Abstract

Suction pump is an electromedical device that is used manually with the help of the user which functions to suck fluids that are not needed by the body. Then the liquid that is not needed is accommodated in a container. Suction is often damaged due to the presence of mucus or liquid that enters the motor rotation. So from the above problems, the author made a Suction Pump Modification equipped with a K-0135 Water Level Sensor. This sensor will also read the liquid that enters the tube with Minimum and Maximum level readings (Low, Middle and Full). The sensor on this tube is very necessary to make it easier for the user to know the liquid is almost full. This research will be conducted in the Sari Mutiara University lab. The type of research method is experimental research, namely conducting direct experiments on the designed tools.The measurement results from the K0135 Water Level Sensor are displayed on the LCD, with measurements of Low, Middle and Full level points.
ANALISA PEMELIHARAAN PREVENTIF BABY INKUBATOR Harahap, Gunawan Fahri; Sijabat, Salomo; Situmorang, Harold; Dabukke, Hotromasari
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 2 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v6i2.3570

Abstract

Baby incubator is a tool that has a function as a treatment and temperature adjustment (heater) for premature babies who really need a temperature that is in accordance with the temperature in the mother's womb. The Baby Incubator uses a heating element that is controlled by a temperature control circuit so that the temperature remains stable. the heater will work when the temperature is less than the predetermined temperature, on the contrary if the temperature sensor is greater than the temperature setting it will automatically turn off. Medical equipment, of course, cannot be separated from damage, both light and heavy, because damage can be caused by improper use of standard operating procedures (SOP), lack of maintenance/maintenance, and incidents/accidents caused by human error. Based on the observations that have been made by the author, it is known that medical equipment requires periodic maintenance to ensure the quality of health services. Preventive maintenance of the baby incubator. Preventive maintenance is maintenance and care activities carried out to prevent damage. Preventive maintenance can be carried out daily or monthly.
ANALISA SISTEM PEMELIHARAAN DAN PERBAIKAN ALAT ELEKTROCARDIOGRAPH Siregar, Adlin Khairi; Sijabat, Salomo; Priyulida, Fitria; Dabukke, Hotromasari
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 2 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v1i2.3585

Abstract

Electrocardiograph is a tool that can display a graph of the electrical signal of the human heart that shows the process of the occurrence of a heartbeat. Through this tool it can be known whether a person's heart rate is normal or not. The method used in this study is qualitative and descriptive. preventive maintenance both from outside and inside the tool and aims to find out the maintenance of the el ectrocardiograph tool this maintenance function is running well, then the quality of the medical equipment used will be good too. From the results of the maintenance and testing of the electrocardiograph that was carried out at the Teaching Hospital of the University of North Sumatra, Medan. The maintenance of the electrocardiograph was carried out by internal calibration with measurements of 30,60,120,240.and by looking at the value of the graph whether it was still curly or not.The results of this study indicate that in practice, the system of maintenance cannot run as it should, due to the limited number of technicians, lack of training, costs, and maintenance procedures that are not in accordance with the planning, operation, and supervision procedures that are not carried out properly.
SISTEM MONITORING SPEED SETTING PADA ROLLER MIXER BERBASIS MIKROKONTROLER ARDUINO UNO Sijabat, Salomo; Andany, Arif
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 1 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v6i1.4504

Abstract

Roller mixer is a laboratory tool that serves to mix blood samples and reagents.  In this case, the substances that are mixed are blood and anti-clotting agents (coagulants).  In the process of mixing the blood, the timer and the rotational value of the motor are set by the selector switch.  The design of the speed setting of the roller mixer tool is made so that the user can control and monitor how much the value of the motor speed used is displayed on the 16x2 LCD display. This research will be conducted at the Electronics Laboratory of Sari Mutiara University, Helvetia District, Medan City.  This type of research method is experimental research, namely conducting direct experiments.  The components in monitoring this tool are microcontroller, display, timer setting, speed setting and roller. After carrying out the research process on the design of this tool, the measurement results obtained from the Infrared Sensor are displayed on the LCD, with a minimum speed measurement of 36, Medium 38 and a maximum of 44 rpm.  With a comparison from a thacometer with an average value of Minimum 44 Medium 54 and maximum 56.
SINTESIS DAN KARAKTERISASI ARANG AKTIF DARI KULIT JENGKOL SEBAGAI ADSORBEN TERHADAP KADAR BOD, COD, TSS PADA LIMBAH CAIR INDUSTRI TAHU Hestina, Hestina; Gultom, Erdiana; Sijabat, Salomo; Aritonang, Barita
CHEDS: Journal of Chemistry, Education, and Science Vol 6, No 2 (2022)
Publisher : Universitas Islam Sumatera Utara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30743/cheds.v6i2.6183

Abstract

Limbah cair industri tahu yang mencemari lingkungan dilakukan pengolahan limbah dengan metode adsorpsi menggunakan arang aktif sebagai adsorben. Penelitian ini bertujuan untuk menurunkan kadar BOD, COD dan TSS pada limbah cair tahu menggunakan arang aktif sebelum dan sesudah diaktivasi dengan H3PO4 konsentrasi 7%. Pembuatan arang aktif dari kulit jengkol telah berhasil dibuat dan sudah memenuhi persyaratan yang ditetapkan SNI 06–3730-1995, diperoleh kadar air sebesar 3,03 %, kadar abu sebesar 2,87 % dan daya serap iodin sebesar 543 mg/L. Analisis spektrum FT-IR arang aktif kulit jengkol memiliki gugus O-H hidroksil, C=O karbonil dan C-O eter. Analisis morfologi permukaan arang aktif memiliki pori-pori dan luas area permukaan yang besar. Limbah cair industri tahu sebelum diadsorpsi dengan arang aktif memiliki kadar yang melebihi nilai ambang batas yaitu, BOD 768 mg/L, COD 745 mg/L dan TSS 752 mg/L. Setelah dilakukan proses adsorpsi menggunakan arang aktif sebagai adsorben kadar BOD, COD dan TSS menjadi turun. Penambahan arang aktif yang tidak diaktivasi dengan H3PO4, kedalam limbah cair tahu diperoleh kadar BOD 100 mg/L, setelah diaktivasi turun menjadi 50 mg/L, kadar COD 200 mg/L, setelah diaktivasi turun menjadi 100 mg/L, kadar TSS 100 mg/L, setelah diaktivasi turun menjadi 65 mg/L. Kesimpulan hasil penelitian kadar BOD, COD dan TSS pada limbah cair industri tahu pasca penambahan arang aktif sebelum dan sesudah diaktivasi memenuhi peraturan Menteri Lingkungan Hidup Republik Indonesia Nomor 5 Tahun  2014. Nilai ambang batas yang diizinkan untuk kadar BOD 150 mg/L, COD 300 mg/L, dan TSS 200 mg/L.
RANCANG BANGUN PULSE OXIMETRY (SPO2) PADA ALAT PASIEN MONITOR Dabukke, Hotromasari; Sijabat, Salomo; Adiansyah, Adiansyah
JURNAL TEKNOLOGI KESEHATAN DAN ILMU SOSIAL (TEKESNOS) Vol. 2 No. 2 (2020): JURNAL TEKNOLOGI, KESEHATAN, DAN ILMU SOSIAL (TEKESNOS)
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Patien Monitor merupakan suatu alat yang digunakan untuk memonitor vital sign pasien, berupa detak jantung, nadi, tekanan darah, temperatur, secara terus menerus. Salah satu parameter patien monitor yaitu pulse oximetri. Pulse oximetry (spo2) merupakan saturasi oksigen dalam darah manusia. Pada penelitian rancang bagun pulse oximetri pada pasien monitor yang bertujuan untuk merancang Pulse Oximetry (Spo2) Pada Alat Pasien Monitor dan untuk mengatahui saturasi oksigen dalam darah. Dengan penelitian ini rancang pulse oximetri diharapkan untuk mendapatkan nilai normal dari saturai oksigen dalam darah diatas 75%. Karena pengaruh saturasi oksigen dalam darah adalahJika tubuh manusia kekurangan atau kelebihan oksigen maka akan menimbulkan penyakit dan gangguan system kerja tubuh yang lain.
Optimasi Pencampuran Thermoplastik (TPE) Karet Alam SIR 3L/High Density Polietilena (HDPE) Dengan Inisiator Benzoil Peroksida Adiansyah*, Adiansyah; Dabukke, Hotromasari; Sijabat, Salomo
JURNAL TEKNOLOGI KESEHATAN DAN ILMU SOSIAL (TEKESNOS) Vol. 3 No. 1 (2021): JURNAL TEKNOLOGI, KESEHATAN DAN ILMU SOSIAL (TEKESNOS)
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Telah dilakukan penelitian mengenai Optimasi Pencampuran Thermoplastik (TPE) Karet Alam SIR 3L/Polietilena Dengan Inisiator Benzoil. Pencampuran dilakukan dengan memvariasikan karet alam SIR 3L/Polietilena dengan penambahan inisiator benzoil peroksida. Untuk mengetahui kualitas komposit yang dihasilkan dilakukan analisa uji tarik, diperoleh peningkatan tanpa inisiator maksimum pada variasi konsentrasi polietilena/karet alam SIR 3L adalah 2phr yaitu kekuatan tarik 2,15 Kgf/mm2 dan kemuluran 9,25 % dan diperoleh peningkatan maksimum pada variasi konsentrasi inisiator Benzoil peroksida (b/b) 3phr: 2phr yaitu kekuatan tarik sebesar 2,80 Kgf/mm2 dan kemuluran 27,80 %. Dari hasil analisa SEM diperoleh bahwa penambahan inisiator diperoleh permukaan yang lebih rata dan homogen. Dari hasil analisa gugus fungsi dengan FT-IR menunjukkan bahwa campuran tersebut hanya merupakan interaksi secara fisik.
RANCANG BANGUN BRIGHTNESS DAN TIMER PADA LAMPU TERAPI INFRA RED Dabukke*, Hotromasari; Sijabat, Salomo; Adiansyah, Adiansyah
JURNAL TEKNOLOGI KESEHATAN DAN ILMU SOSIAL (TEKESNOS) Vol. 3 No. 2 (2021): JURNAL TEKNOLOGI, KESEHATAN DAN ILMU SOSIAL (TEKESNOS)
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pekerjaan dan aktivitas sehari-hari dapat menimbulkan nyeri sendi, otot, atau tulang, bahkan sekitar 80 persen warga kota mengalami gangguan yang disebut muskuloskeletal ini. Penyakit inipun menjadi penyumbang pasien terbesar kedua di seluruh dunia setelah influenza, jumlah penderita muskuloskeletal diperkirakan akan meningkat 20-35% dalam kurun waktu 10-15 tahun ke depan. Salah satu alat yang digunakan untuk terapi penyakit muskuloskeletal ini adalah alat terapi Infra Merah, dimana alat terapi infra merah saat ini masih dioperasikan secara manual dan tidak terdapat data sistem waktu penyinaran pada saat alat tersebut digunakan sehingga tindakan terapi terhadap pasien tidak dapat di monitor dengan baik sehingga bisa berakibat fatal terhadap pasien. Untuk mengatasi masalah tersebut, dirancang sebuah alat terapi yang Infra Merah (IR) yang dilengkapi dengan pengaturan keccerahan (brightness) dan pengatur waktu (timer) secara otomatis. Dari hasil penelitian diproleh alat berbasis Arduino Uno sehingga tingkat kecerahan yang dihasilkan lampu yang dulunya masih manual, kini dapat diatur kecerahannya dan juga dapat mati secara otomatis apabila waktu dapat dieting lampu serta mencapai waktu yang telah disetting.
Pemanfaatan Polipropilena Bekas Untuk Papan Partikel (particle board) Jerami Padi/Batang Pisang/pp-g-ma/polipropilena Adiansyah*, Adiansyah; Sijabat, Salomo; Dabukke, Hotromasari; Aulia, Putri
JURNAL TEKNOLOGI KESEHATAN DAN ILMU SOSIAL (TEKESNOS) Vol. 4 No. 1 (2022): JURNAL TEKNOLOGI KESEHATAN DAN ILMU SOSIAL (TEKESNOS)
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Telah dilakukan penelitian pemanfaatan polipropilena bekas untuk pembuatan papan partikel dengan menggunakan jerami padi/batang pisang/PP-g-MA/polipropilena. Pembuatan papan partikel dilakukan dengan metode refluk dengan pelarut organik, hasil penelitian dikarakterisasi dengan menggunakan FT-IR, SEM, daya serap air, MoE dan MOR. Papan partikel yang memiliki nilai optimum adalah papan partikel (III: 70:40:10:30) dan memiliki nilai daya serap air sebesar 1,96%, keteguhan lentur (MoE) sebesar 4916,46 kgf/cm2, kekuatan patah dengan nilai 25,4 kgf/cm2 dan keteguhan patah (MoR) sebesar 309,480 MPa. Hasil Analisa FTIR menunjukkan telah terjadi reaksi antara polipropilena, PP-g-MA, serbuk batang pisang dan serbuk jerami padi karena adanya puncak serapan gugus OH dari selulosa. Dari hasil foto SEM juga memperlihatkan adanya interaksi antara serbuk batang pisang, serbuk jerami padi, polipropilena dan PP-g-MA terlihat bahwa pori-pori permukaan yang di peroleh lebih halus dan rata.