Claim Missing Document
Check
Articles

Found 26 Documents
Search

Efisiensi Terhadap Pemenuhan Ketersediaan Air Bersih dengan Recycle Effluent dari Proses IPAL menggunakan Teknologi Reverse Osmosis di PT. Bumi Menara Internusa Industri Pengolahan Hasil Laut Ervina, Dea Febrica; Purnomo, Yayok Suryo
Environmental Engineering Journal ITATS Vol 3, No 2 (2023): Environmental Engineering Journal ITATS
Publisher : Teknik Lingkungan, Institut Teknologi Adhi Tama Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.envitats.2023.v3i2.4484

Abstract

AbstrakPemenuhan ketersediaan air untuk menunjang proses produksi pada perusahaan sangatlah penting. Pada umumnya perusahaan untuk memenuhi ketersediaan air mengguankan suplai dari pihak PDAM. Namun kuantitas yang berasal dari pihak PDAM masih kurang untuk memenuhi kebutuhan proses produksi. Dengan permasahaan yang ada mengenai kekurangan air dan demi menjaga kuantitas ketersediaan air bersih maka perusahaan ini melakukan recycle hasil efluen IPAL menjadi air minum. Pengolahan yang dilakukan yaitu menggunakan teknologi reverse osmosis. Penelitian ini dilakukan dnegan tujuan mengetahui proses recycle air limbah menggunakan teknologi RO dan mendapatkan efisiensi biaya air bersih di perusahaan dengan membandingkan antara biaya operasional RO dan biaya operasional pembelian air bersih dari pihak PDAM. Diperoleh hasil bahwa pengolahan efluen IPAL dapat di recycle menjadi air minum dengan teknologi RO. Parameter yang dihasilkan oleh hasil teknologi ini juga telah memenuhi standar baku mutu Peraturan Menteri Kesehatan Nomor: 492/MENKES/Per/IV/2010. Unit yang digunakan pada pengolahan ini yaitu sistem DAF dengan penambahan koagulan PAC, sand filter,  carbon filter, ultrafiltration, dan reverse osmosis. Perhitungan efisiensi biaya setiap m3 air yang diperoleh dari pengolahan teknologi reverse osmosis dan suplai dari PDAM pada 5 bulan terakhir dapat mencapai rata-rata Rp78.503.990,47.Kata Kunci : Reverse Osmosis, Air Minum, Efisiensi.
EVALUASI INSTALASI PENGOLAHAN AIR LIMBAH RSUD DR. MOHAMMAD ZYN Arfani, Nabila Nur; Purnomo, Yayok Suryo
Environmental Engineering Journal ITATS Vol 3, No 1 (2023): Environmental Engineering Journal ITATS
Publisher : Teknik Lingkungan, Institut Teknologi Adhi Tama Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.envitats.2023.v3i1.3789

Abstract

Kegiatan rumah sakit tentu tak lepas dari berjalannya suatu pengolahan limbah dimana hal ini berguna untuk mencegah adanya gangguan kesehatan. Berdasarkan hasil observasi dan monitoring yang telah dilakukan di lapangan, diketahui RSUD dr. Mohammad Zyn Sampang telah memiliki Instalasi Pengolahan Air Limbah (IPAL), namun belum adanya kegiatan evaluasi IPAL tersebut. Tujuan dilakukannya penelitian ini, ialah untuk mendapat suatu hasil analisis efektivitas dari kinerja Instalasi Pengolahan Air Limbah RSUD dr. Mohammad Zyn Sampang dalam menurunkan berbagai kadar pencemar yang terkandung dalam air limbah hasil kegiatan rumah sakit. Dari hasil penelitian, dapat diketahui bahwa hasil outlet bangunan IPAL yang dimiliki RSUD dr. Mohammad Zyn Sampang termasuk dalam kategori efisien. Kinerja bangunan IPAL tersebut dapat dilihat dari penurunan suhu dari 31oC menjadi 30.7oC, kandungan BOD dari 30 mg/L menjadi 7 mg/L, kandungan COD dari 60 mg/L menjadi 13 mg/L, kandungan TSS dari 8 mg/L menjadi 4 mg/L, kandungan NH3-N Bebas 2.71 mg/L menjadi 0.09 mg/L, PO4 dari 0.31 mg/L menjadi 0.02 mg/L, kandungan MPN-Kuman Gol. Koli 9140 mg/L menjadi 722 mg/L, dan kandungan pH dari 7.9 menjadi 8.1. Penelitian ini dilakukan untuk memberikan evaluasi dan saran perbaikan kinerja IPAL RSUD dr. Mohammad Zyn dengan memperhatikan hasil effluent dan presentase efisiensi IPAL.
EVALUASI PENGELOLAAN LIMBAH B3 RSUD dr. MOHAMMAD ZYN SAMPANG Shafa, Putrie Radhika; Purnomo, Yayok Suryo
Environmental Engineering Journal ITATS Vol 3, No 1 (2023): Environmental Engineering Journal ITATS
Publisher : Teknik Lingkungan, Institut Teknologi Adhi Tama Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.envitats.2023.v3i1.3788

Abstract

Pemerintah Kabupaten Sampang memiliki RSUD dr. Rumah Sakit Mohammad Zyn Kabupaten Sampang, salah satu fasilitas pelayanan prima yang terletak di Jl. Rajawali No. 10 Sampang dan memiliki total 229 tempat tidur. Limbah padat, cair, dan gas, termasuk limbah operasional institusi medis, mengandung limbah benda tajam, infeksius, patologis, radioaktif, farmasi, sitotoksik, kimia, dan peralatan. Sesuai dengan kebutuhan yang relevan, penelitian ini berupaya untuk menentukan alur pengelolaan limbah B3, dengan tujuan menghasilkan limbah B3 seminimal mungkin. Teknik pengumpulan data digunakan dalam investigasi ini. Sebanyak 4.548,5 kg limbah B3 mencapai TPS pada Agustus, diikuti 5.177 kg pada September, 5.640 kg pada Oktober, dan 6.278 kg pada November. Sampah B3 masuk insinerator dalam empat bulan berbeda: 5310 kg pada Agustus, 4877 kg pada September, 4785 kg pada Oktober, dan 5196 kg pada November. Insinerator menghasilkan 819,86 kg abu pada bulan Agustus; 804,56 kg pada bulan September; 842,92 kg pada bulan Oktober; dan 688,53 kg pada bulan November. Temuan penelitian menunjukkan bahwa pengelolaan limbah mematuhi semua undang-undang yang relevan. Pengumpulan limbah medis di TPS B3 merupakan salah satu area yang perlu ditingkatkan antara lain. Pengiriman limbah medis tercepat ke pihak ketiga harus diupayakan.
Sistem Pengolahan dan Aplikasi Pemanfaatan Air Limbah Kegiatan Industri dan Kegiatan Domestik di PT. XX Kabupaten Sidoarjo Putri, Mutia Chantika; Purnomo, Yayok Suryo
Envirous Vol. 4 No. 2 (2024): Jurnal Envirous
Publisher : UPN "Veteran" Jawa Timur

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33005/envirous.v4i2.171

Abstract

PT. XX merupakan industri yang bergerak di bidang pembuatan plastic lembaran yang berlokasi di Kabupaten Sidoarjo. Industri ini menghasilkan air buangan dengan kadar COD yang cukup tinggi, namun PT. XX dapat memanfaatkan air limbahnya kembali (reuse). Oleh karena itu peneliti tertarik untuk mengkaji lebih dalam mengenai sistem pengolahan yang ada pada PT. XX tersebut. Penelitian ini bertujuan untuk mengetahui efektivitas pengolahan air limbah campuran dan efisiensi pemanfaatan air limbah campuran PT. XX. Penelitian ini menggunakan strategi analisis deskriptif-kuantitatif berdasarkan sumber informasi primer dan sekunder. Hasil penelitian ini yakni Unit Intalasi Pengolahan Air Limbah yang digunakan dapat menurunkan parameter pH, TSS, COD, dan BOD sehingga telah memenuhi baku mutu yang telah ditentukan. Pemanfaatan air limbah pada PT. XX dengan luas lahan terbuka sebesar 260.661 m2 dapat digunakan untuk kegiatan penyiraman Ruang terbuka Hijau (RTH), kegiatan flushing toilet, air tangki pemadam kebakaran, dan juga air hydrant. Selain itu efisiensi penggunaan air limbah campuran PT. XX dapat dimanfaatkan secara keseluruhan menggapai 98,9%. PT XX is an industry which operates in the field of making plastic sheets which is located in Sidoarjo Regency. This industry produces waste water with quite high COD levels, but PT XX can reuse its waste water. Therefore, researchers are interested in studying in more depth the existing processing system at PT XX. This research aims to determine the effectiveness of mixed wastewater treatment and the efficiency of PT XX's mixed wastewater utilization. This research uses a descriptive-quantitative analysis strategy based on primary and secondary sources of information. The results of this research are that the Waste Water Treatment Plant Unit used can reduce the pH, TSS, COD and BOD parameters so that it meets the specified quality standards. PT XX produces mixed wastewater with a total discharge of 1,608 m3/day, with a total discharge of wastewater in WWTP 1 processing which is discharged into water bodies of 403 m3/day, while the total wastewater discharge in WWTP 2 which is reused is 1,190.54 m3/day, which is used for watering Green Open Space (RTH), toilet flushing activities, fire extinguisher water, and also hydrant water. Furthermore, the efficiency of using PT XX's mixed wastewater which can be utilized as a whole reaches 98.9%.
Efisiensi Pengolahan Cr(VI) dengan Resin Immobilized Photocatalyst Technology (RIPT) Katalis ZnO Zahrah, Aurelia Asilah; Purnomo, Yayok Suryo; Murti, Restu Hikmah Ayu
Jurnal Serambi Engineering Vol. 10 No. 1 (2025): Januari 2025
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Waste water from the nickel mining process has the potential to contaminate the environment due to the presence of hazardous metals such as chromium (Cr) in the form of Cr(VI) and Cr(III), iron (Fe), nickel (Ni) and other heavy metals. These substances are of great concern because of their toxicity, which can have adverse effects on ecosystems and human health. This study was conducted to investigate the effects of UV-C lamp light intensity, contact time and RIPT-ZnO weight on the removal of hexavalent chromium (Cr(VI)) from nickel wastewater. The method used in this research involved immobilisation of photocatalysts on resin with RIPT concentrations of 5g, 10g and 15g and variations in UV-C lamp light intensity of 8W, 18W and direct sunlight. The contact times tested were 0 minutes, 30 minutes, 60 minutes, 120 minutes and 180 minutes, with the focus of the analysis on the Cr(VI) concentration. The results showed that increasing RIPT dosage resulted in higher Cr(VI) removal percentages. The highest Cr(VI) removal was achieved with a 15 gram RIPT dosage, especially when ZnO was used. The optimum contact time for maximum Cr(VI) removal was 180 minutes, indicating that the longer the wastewater is exposed to RIPT, the higher the removal rate. The study found that the use of ZnO in the RIPT technology achieved the highest Cr(VI) removal efficiency, reaching 96%.
Analisis Timbulan Emisi Karbon Dioksida Area Kampus UPN “Veteran” Jawa Timur Ramadhan, Firza; Purnomo, Yayok Suryo; Jawwad, Muhammad Abdus Salam
Jurnal Serambi Engineering Vol. 10 No. 1 (2025): Januari 2025
Publisher : Faculty of Engineering, Universitas Serambi Mekkah

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The green space in the UPN Veteran campus area in East Java is a campus effort to control carbon dioxide (CO2) emissions generated by campus activities. Green spaces can absorb and store CO2 and convert it into energy and O2 through photosynthesis. The results showed that the CO2 emissions generated by the use of motorised vehicles, human respiration activities and the use of LPG energy at the research site amounted to 7,317,565.6 kgCO2/year. The total carbon uptake of the study area was 13,422,291 kgCO2/year. From the comparison between the total carbon dioxide (CO2) absorption and the generation of carbon dioxide (CO2) emissions at the research site, it is known that Green Space can absorb or reduce CO2 emissions as a whole.
Penurunan Kekeruhan dan TSS Air Sungai dengan Memanfaatkan Koagulan dari Cangkang Keong Sawah (Pila Ampullacea) Lestari , Putri Ayu; Purnomo, Yayok Suryo
Envirous Vol. 3 No. 2 (2023): Jurnal Envirous
Publisher : UPN "Veteran" Jawa Timur

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33005/envirous.v3i2.7

Abstract

Cangkang keong sawah (Pila ampullacea) dapat menjadi limbah bagi lingkungan karena tidak dapat diolah dan dimanfaatkan lebih lanjut, namun dapat diekstraksi agar dapat digunakan sebagai koagulan. Penelitian ini bertujuan untuk mengetahui efektivitas ekstrak yang berasal dari cangkang keong sawah sebagai koagulan melalui proses pengolahan air koagulasi-flokulasi dan mengetahui perbedaan signifikan pada setiap parameter uji. Penelitian ini merupakan penelitian eksperimental dengan menggunakan variasi dosis koagulan yaitu 50, 100, 150, 200 dan 250 mg/L. Pada penurunan presentase kekeruhan koagulan cangkang keong sawah sebesar 83-96,42% sedangankan koagulan sintesis PAC sebesar 85-99%. Pada tingkat keasaman (pH) koagulan cangkang keong sawah 7.2-7.9 sedangkan pH koagulan sintesis PAC 6.8-7.5, keduanya masih dalam range 6-9.
Method Gemi Self Assessment Untuk Identifikasi Management Lingkungan Rumah Pemotongan Unggas Di Pasar Tambahrejo Surabaya Pandriratri, Purnasari; Rachmanto, Tuhu Agung; Purnomo, Yayok Suryo; Cahyonugroho, Okik Hendriyanto
Envirous Vol. 3 No. 2 (2023): Jurnal Envirous
Publisher : UPN "Veteran" Jawa Timur

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33005/envirous.v3i2.15

Abstract

Pasar Tambahrejo merupakan salah satu pasar tradisional kota Surabaya yang memiliki usaha pemotongan ayam yang sudah memenuhi syarat dan ketentuan, sehingga usaha pemotongan ayam tersebut sudah mendapat izin resmi pendirian dari pemkot Surabaya. Namun, dalam setiap proses produksi pasti menghasilkan limbah yang mempengaruhi pencemaran lingkungan. Masalah pencemaran lingkungan selalu mempunyai dampak yang harus diperhatikan bagi perusahaan. Disisi lain juga dapat menyebabkan munculnya berbagai penyakit jika pengolahannya tidak diperhatikan. Oleh karena itu, diperlukan perencanaan untuk melaksanakan ISO 14001:2015 guna menunjang perkembangan perusahaan. Pada penelitian ini menggunakan checklist GEMI (Global Environmental Management Initiative) dan metode GAP analysis, kemudian didapatkan hasil persentase 5 klausul yaitu kepemimpinan sebesar 50%, perencanaan 47%, operasional 42%, evaluasi performa 39%, dan perbaikan berkelanjutan 50%.
Evaluasi Sistem Pengelolaan Sampah TPS 3R Jambangan Dan TPS 3R Tenggilis Berdasarkan 5 Aspek Putri, Adellia Zanati; Purnomo, Yayok Suryo
Envirous Vol. 3 No. 2 (2023): Jurnal Envirous
Publisher : UPN "Veteran" Jawa Timur

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33005/envirous.v3i2.19

Abstract

Kota Surabaya telah mendapatkan banyak penghargaan berskala internasional, yang menjadikan Kota Surabaya sebagai role model pengelolaan sampah di Asia-Pasifik. Salah satu contoh aplikasi pengelolaan sampah yang diterapkan oleh Pemerintah Kota Surabaya adalah dengan dibangunnya TPS 3R di Surabaya. Namun demikian Kota Surabaya masih harus berbenah dengan melakukan evaluasi kepada TPS 3R. Dalam penelitian kali ini terdapat 2 TPS 3R yang dipilih untuk diteliti, yaitu TPS 3R Jambangan dan TPS 3R Tenggilis. Evaluasi didasarkan pada 5 aspek yang terdapat dalam SNI 3242:2008. 5 Aspek Tersebut adalah Aspek Peraturan/Hukum, Aspek Kelembagaan/Organisasi, Aspek Pembiayaan/Retribusi, Aspek Teknis Operasional, dan Aspek Peran Serta Mayarakat. Berdasarkan hasil Observasi & wawancara, TPS 3R Tenggilis tidak memenuhi Aspek Kelembagaan/Organisasi, Sub Aspek Struktur Organisasi. Menurut hasil kuesioner, Kedua TPS memenuhi semua Aspek beserta Sub Aspek yang dijadikan pertanyaan. Berdasarkan hasil uji laboratorium untuk pupuk kompos, kedua TPS memiliki pupuk kompos dengan kandungan Nitrogen (N), Fosfor ( ), Kalium ( ), dan juga C organik sesuai dengan ketentuan SNI 19-7030-2004, namun untuk rasio C/N belum memenuhi.
PENYISIHAN BAKTERI E. COLI MENGGUNAKAN RADIASI SINAR ULTRAVIOLET DAN SEMIKONDUKTOR TIO2 PADA AIR SUMUR DESA KENONGO, SIDOARJO Labina, Hendrikus F.; Purnomo, Yayok Suryo
Envirous Vol. 5 No. 1 (2024): Jurnal Envirous
Publisher : UPN "Veteran" Jawa Timur

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33005/envirous.v2i2.95

Abstract

Ada banyak sumber air di muka bumi ini, dan terbagi menjadi 4 jenis, yaitu air laut atau air asin, air atmosfer atau air hujan, air permukaan termasuk sungai, danau, rawa, dan badan air lainnya. Terakhir, ada air tanah. Air sumur yang tercemar bakteri patogen yang ditunjukkan oleh E. coli membuat air sumur tidak dapat diminum sebagai air minum yang bersih. Escherichia coli merupakan bakteri yang menunjukkan adanya pencemaran air bersih. Penelitian ini bertujuan untuk merancang suatu alat untuk menghilangkan E. coli agar air sumur penduduk Porong Kabupaten Sidoarjo dapat memenuhi kebutuhan sehari-hari. Proses fotolisis dengan perubahan diameter reaktor yaitu 2,5", 3" dan 4', dan waktu pemaparan 5, 10, 15, 20 dan 25 menit, akan digunakan untuk mengecualikan E. Proses fotolisis pada reaktor ini menggunakan lampu UV 20 watt, = 253,7 nm. Analisis data yang digunakan adalah menghilangkan korelasi antara Escherichia coli dengan proses fotolisis dan kombinasi perubahan reaktor. Setelah terkena reaktor 2,5 inci selama 25 menit, tingkat penghilangan E. coli mencapai 86%. Pada saat yang sama, selama proses fotolisis, reaktor 3 diekspos selama 25 menit, dan laju penyisihan E. coli mencapai 83%. Dan waktu pemaparan pada reaktor 4" adalah 25 menit, dan laju penyisihan E. coli mencapai 81%