p-Index From 2020 - 2025
0.444
P-Index
This Author published in this journals
All Journal Jurnal Talenta Sipil
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Derajat Kepadatan Lapis Pondasi Agregat Tanpa Penutup Aspal Menggunakan Metode Sand Cone pada Proyek Rekonstruksi Jalan Kecamatan Serai Serumpun, Kabupaten Tebo di Ruas Jalan Tanjung Aur Seberang-Malako Tinggi Yumardi, Yumardi; Wijaya, Sucitra; Kutni, Darul; Rianto, Doli Jumat; Marwadi, Aji
Jurnal Talenta Sipil Vol 7, No 2 (2024): Agustus
Publisher : Universitas Batanghari Jambi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33087/talentasipil.v7i2.625

Abstract

Road infrastructure is very important for the economic progress of Tanjung Aur Seberang village residents. Economic development in Tanjung Aur Village, Tebo Regency has significantly increased traffic levels. If this is not balanced by improving the quality of transportation facilities and infrastructure, then this could cause serious problems. Determining the value of the degree of density of the foundation layer aggregate (soil) class S  in obtaining soil stability with safe conditions in accordance with the requirements of density standards is the aim of this research. The methods used are direct tests in the field and in the laboratory. Testing soil density in the field using a sand cone tool follows the provision stated in  SNI 03-2828-1992, while testing soil density in the laboratory follows the provisions stated in SNI 1742-2008. Soil density testing intervals vary between 50 meters, 75 meters, 100 meters, 150 meters, 200 meters depending on location conditions. The results sand cone testing was carried out on roads from STA 2+000 to 3+800. In the first test with 9 test points, the field density was obtained below 95%, namely STA 2+100 (94,141%), STA 2 +550 (94,389%) and STA 3 +800 (94,289). Theses results indicate that the required standard degree of field density has not been achieved, so that the base layer of class S aggregate  can be added and compaction can be carried out again. And from STA 0 + 005 to 4 + 200 in the second test with 26 test points. Test results using a sand cone tool show that the average water content value is 7.513% with a density reaching 98.846%. and these results were in accordance with applicable standard requirements.
Pemanfaatan Palm Oil Fuel Ash (POFA) Sebagai Pengganti Sebagian Agregat Halus dalam Campuran Beton Nasution, Ari Endra; Wijaya, Sucitra; Christalline, Silvia; Renjani, Muhammad Sodri
Jurnal Talenta Sipil Vol 8, No 2 (2025): Agustus
Publisher : Universitas Batanghari Jambi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33087/talentasipil.v8i2.1015

Abstract

This study investigates using Palm Oil Fuel Ash (POFA) as a partial substitute for some of fine aggregate (sand) in concrete mixtures. The goal is to determine the optimal percentage of POFA by testing several variations of its use as a substitute for fine aggregate. The study employed an experimental methodology involving the preparation of 15 cm x 15 cm x 15 cm cubic test specimens in accordance with SNI 03-2834-2000 (Procedures for Preparing Normal Concrete Mix Designs). The POFA percentages were 0% (control specimen), 5%, 6%, 7%, 8%, 9%, 10%, and 20%.  Test results showed that the compressive strength of concrete produced using 0% POFA (normal concrete) was 228.6 kg/cm². The compressive strengths of concrete produced using 5%, 6%, 7%, 8%, 9%, and 10% POFA were 134.9, 156.9, 159.7, 198.3, 198.3, and 151.5, 159,7 kg/cm², respectively. The test results indicate that adding POFA to the concrete decreased its compressive strength relative to control specimen. However, substituting fine aggregate with POFA at 8% and 9% resulted in higher compressive strength than the other variations. The results also indicated the potential for an increase in concrete compressive strength between 10% and 20%.