Amelia, Fatihaturrizky
Departemen Teknik Sipil Dan Lingkungan, Fakultas Teknologi Pertanian, Institut Pertanian Bogor

Published : 5 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 5 Documents
Search

MODEL ESTIMASI BIOKINETIKA UNTUK PROSES POST-DENITRIFIKASI AIR LIMBAH DOMESTIK PADA UNIT ANAEROBIC BAFFLED REACTOR Allen Kurniawan; Fatihaturrizky Amelia; Adhirajasa Wirayudhatama; Sulpa Yudha Prawira
JURNAL SUMBER DAYA AIR Vol 17, No 2 (2021)
Publisher : Bina Teknik Sumber Daya Air, Kementerian Pekerjaan Umum dan Perumahan Rakyat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32679/jsda.v17i2.701

Abstract

This study developed a combination of Continuous Stirred Tank Reactor (CSTR) for the acid fermentation and the Anaerobic Baffled Reactor (ABR) post-denitrification through high nitrite injection. Volatile Fatty Acids (VFAs) as a substrate for the post-denitrification process were optimally produced in the acid fermentation process. The aim of this study was to obtain the estimation of biokinetic values to predict the effluent wastewater quality in ABR post-denitrification process under unsteady state. The reactor was operated for HRT 7 days at temperature 25-28 ˚C and pH 6-7,2. The influent and effluent substrate concentration were monitored continuously for 160 days. Post-denitrification biokinetic from the Contois equation resulted in the value of hydrolysis rate (Kh) of 0.077 day-1, the substrate transport rate (k) of 4.364×10-6 Lmg-1day-1, maximum specific growth rate (μmax) of 0.559 day-1, half saturation constant (KS) of 0.209 mgL-1, microbial decay coefficient (b) of 0.0145 days-1; yield coefficient (Y) of 0.084 g-VSSg-COD-1. The validation of biokinetic parameters based on statistical analysis showed fairly precise results following the trend of experimental data to determine the substrate concentration in the effluent unit. Therefore, the biokinetic values can be applied in the design of ABR post-denitrification using primary sludge incorporation with high strength nitrate.Keywords:  Anaerobic baffled reactor, biokinetics, Contois, hydrolysis, post-denitrification.
Estimasi Nilai Hydraulic dan Solid Loading Rate Tipe Pengendapan Diskrit dan Flok Pada Proses Lumpur Aktif Untuk Pengolahan Limbah Cair Industri Kertas Fatihaturrizky Amelia; Owen Jacob Notonugroho; Satyanto Krido Saptomo; Allen Kurniawan
Jurnal Ilmu Lingkungan Vol 20, No 3 (2022): July 2022
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.20.3.445-456

Abstract

Beban limbah cair industri kertas meningkat seiring dengan peningkatan produksi kertas di Indonesia. Konsentrasi COD berkisar antara 8.300–45.384 mg/L O2 dan TSS sebesar 41.000 mg/L. Salah satu upaya untuk mengurangi beban COD dan TSS di dalam limbah cair industri kertas adalah dengan memanfaatkan proses lumpur aktif. Penelitian ini difokuskan pada pengaruh proses sedimentasi di dalam unit lumpur aktif untuk mereduksi COD dan TSS. Penelitian ini juga mencakup analisis dua tipe pengendapan, yaitu pengendapan partikel diskrit dan pengendapan flok. Tujuan utama penelitian ini untuk mengestimasi nilai hydraulic loading rate dan solid loading rate serta rekomendasi dimensi unit sedimentasi lumpur aktif. Penelitian ini meliputi kegiatan monitoring kinerja proses dengan tiga variasi waktu detensi (HRT). Beberapa variabel yang diperhatikan untuk mencapai tujuan penelitian ini, antara lain kecepatan pengendapan bebas (v), percepatan gravitasi (g), massa jenis partikel (ρs), massa jenis fluida (ρ), diameter partikel (d), dan koefisien penarikan atau drag coefficient (Cd). Pengukuran reduksi COD mengacu pada SNI 6989.2:2009 dan pengukuran reduksi TS mengacu pada SNI 06-6989.26-2005. Penelitian ini menunjukkan bahwa kecepatan pengendapan discrete particle settling tergantung pada karakteristik satuan partikel berdasarkan diameter partikel. Kecepatan pengendapan flocculant settling tergantung pada pengaruh interaksi partikel dalam pembentukan flok atau gumpalan beberapa entitas partikel. Jika ditinjau dari nilai umur lumpur (SLR), HRT 8 jam dan HRT 12 jam menunjukkan kondisi under loaded pada unit sedimentasi. Sementara itu, nilai HLR dan SLR pada HRT 6 jam telah memenuhi rentang kriteria desain lumpur aktif. Dengan demikian, desain terbaik untuk unit sedimentasi sekunder lumpur aktif, yaitu HRT 6 jam dengan HLR sebesar 42,16 m3/m2hari, SLR sebesar 102,45 kg/m2hari dan rata-rata reduksi padatan total mencapai 89,26%.ABSTRACTThe influence of paper production affect simultenously to the increase of pulp and paper wastewater in Indonesia. The COD concentration ranged from 8,300–45,384 mg/L O2 and TSS was 41,000 mg/L. Reducing COD and TSS concentrations in the paper industry wastewater is to utilize by using activated sludge processes. This research was focused on the effect of sedimentation process in activated sludge to reduce COD and TSS. This research also included the analysis of two types of deposition, namely discrete particle settling and floc settling. Main objective this research was directed at determining the value of the hydraulic loading rate and solid loading rate as well as recommendations for the dimensions of the activated sludge sedimentation unit. This research included monitoring of process performance with three variations of detention time (HRT). There were several variables that are considered to achieve the objectives of this study, including free deposition velocity (v), acceleration due to gravity (g), particle density (ρs), fluid density (ρ), particle diameter (d), and drag coefficient. coefficient (Cd). The COD and TS reduction measurement refered to SNI 6989.2:2009 and SNI 06-6989.26-2005, respectively. This study showed that the speed of discrete particle settling depends on the characteristics of the particle unit as seen from the particle diameter. The deposition rate of flocculant settling depends on the effect of particle interactions in the formation of flocs or agglomerates of several particle entities. When viewed from the SLR value obtained, the 8-hour HRT and 12-hour HRT indicated that the sedimentation unit was in an under-loaded condition. Meanwhile, the HLR and SLR values at HRT 6 hours complied the activated sludge design criteria. Thus, the best design for the activated sludge secondary sedimentation unit was HRT 6 hours with an HLR of 42,16 m3/m2day, an SLR of 102,45 kg/m2day and an average total solids reduction of 89,26%.
Pengaruh Sudut Inklinasi Plate-Settler terhadap Kecepatan Vertikal Proses Sedimentasi pada Pengolahan Limbah Cair Kertas Fatihaturrizky Amelia; Oktavian Wahyu Pratama Ajie; Allifiya Salsabil Nugrohoputri; Nurwahid Dimas Saputro; Allen Kurniawan
Semesta Teknika Vol 25, No 2 (2022): NOVEMBER 2022
Publisher : Universitas Muhammadiyah Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.18196/st.v25i2.15223

Abstract

Pengolahan limbah cair industri kertas memberikan produk kontaminan yang berbahaya ketika dibuang ke lingkungan tanpa pengolahan. Beban kontaminan yang tinggi memberikan efek terhadap beratnya beban pengolahan limbah secara biologis. Kecepatan pengendapan merupakan salah satu komponen terpenting di dalam meningkatkan kinerja unit sedimentasi, antara lain melalui penggunaan plate-settler. Penelitian ini bertujuan menganalisis pengaruh penambahan plate-settler dalam berbagai variasi inklinasi. Metode penelitian ini dilakukan melalui pengamatan terhadap kecepatan jatuh partikel, dan estimasi kecepatan jatuh yang dipengaruhi oleh sudut inklinasi platesettler pada unit sedimentasi. Karakteristik limbah cair industri kertas menunjukkan kecenderungan membentuk flok dan memiliki kemampuan pengendapan yang tinggi yang ditunjukkan oleh penurunan lumpur sebesar 29,53 cm pada 2,5 menit pertama. Modifikasi mekanisme pengendapapan dapat menambahkan plate-settler untuk meningkatkan efisiensi reduksi partikel dengan sudut optimum sebesar 60o hingga 75o. Nilai ini menunjukkan sudut inklinasi plate-settler yang memengaruhi mekanisme penyisihan total padatan di dalam proses seimentasi, selain kecepatan vertikal partikel.
Estimasi Kualitas Efluen Air Lindi Unit Stabilisasi Berdasarkan Parameter Biokinetika pada Sistem Konfigurasi Kontak Stabilisasi Oktavian Wahyu Pratama Ajie; Owen Jacob Notonugroho; Fatihaturrizky Amelia; Ariani Dwi Astuti; Allen Kurniawan
Jurnal Ilmu Lingkungan Vol 22, No 2 (2024): March 2024
Publisher : School of Postgraduate Studies, Diponegoro Univer

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/jil.22.2.528-542

Abstract

Pengolahan air lindi dibutuhkan untuk mereduksi kontaminan material organik, anorganik, dan mikroorganisme patogen. Pengolahan air lindi secara biologis melalui unit kontak stabilisasi adalah unit yang sangat efektif dipilih terkait kinerja dan faktor nilai ekonomi untuk menyisihkan kandungan polutan organik air lindi. Akan tetapi, kinerja dan pemodelan proses stabilisasi pada unit ini belum dianalisis secara detail untuk implementasi skala lapangan. Penelitian ini bertujuan untuk mengevaluasi kinerja proses stabilisasi berdasarkan variasi waktu detensi (HRT), mengestimasi nilai parameter biokinetika terbaik, dan memprediksi konsentrasi substrat efluen hasil pemodelan. Penelitian ini dilakukan pada skala laboratorium menggunakan tiga variasi HRT, sebesar 4, 5, dan 6 jam dan disimulasikan di dalam model pertumbuhan mikroorganisme Monod, Contois, Blackman, dan Chen-Hashimoto pada kondisi aliran tidak tunak. Penyisihan kontaminan terbaik pada unit stabilisasi berdasarkan hasil analisis kinerja sebesar 82% nitrit, 42% amonia, dan 38% chemical oxygen demand (COD) diperoleh dari HRT 6 jam. Parameter biokinetika terbaik berdasarkan analisis numerik dan uji validasi untuk nilai Ke, Y, μmax, dan Ks dihasilkan berturutturut sebesar 2,05 hari-1; 32,88 mgMLVSS/mgCOD; 0,57 hari-1; dan 24,38 mg/L dari model Monod. Konsentrasi efluen COD rata-rata dari model Monod diestimasi sebesar 206,28 ± 27,39 mg/L untuk HRT 4 jam; 159,25 ± 72,06 mg/L untuk HRT 5 jam; serta 126,32 ± 38,44 mg/L untuk HRT 6 jam. Nilai parameter biokinetika tersebut dapat diimplementasikan untuk perencanaan unit stabilisasi pada konfigurasi kontak stabilisasi air lindi skala lapangan.
MODEL ESTIMASI BIOKINETIKA UNTUK PROSES POST-DENITRIFIKASI AIR LIMBAH DOMESTIK PADA UNIT ANAEROBIC BAFFLED REACTOR Kurniawan, Allen; Amelia, Fatihaturrizky; Wirayudhatama, Adhirajasa; Prawira, Sulpa Yudha
JURNAL SUMBER DAYA AIR Vol 17, No 2 (2021)
Publisher : Direktorat Bina Teknik Sumber Daya Air, Kementerian Pekerjaan Umum dan Perumahan Rakyat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32679/jsda.v17i2.701

Abstract

This study developed a combination of Continuous Stirred Tank Reactor (CSTR) for the acid fermentation and the Anaerobic Baffled Reactor (ABR) post-denitrification through high nitrite injection. Volatile Fatty Acids (VFAs) as a substrate for the post-denitrification process were optimally produced in the acid fermentation process. The aim of this study was to obtain the estimation of biokinetic values to predict the effluent wastewater quality in ABR post-denitrification process under unsteady state. The reactor was operated for HRT 7 days at temperature 25-28 ˚C and pH 6-7,2. The influent and effluent substrate concentration were monitored continuously for 160 days. Post-denitrification biokinetic from the Contois equation resulted in the value of hydrolysis rate (Kh) of 0.077 day-1, the substrate transport rate (k) of 4.364×10-6 Lmg-1day-1, maximum specific growth rate (μmax) of 0.559 day-1, half saturation constant (KS) of 0.209 mgL-1, microbial decay coefficient (b) of 0.0145 days-1; yield coefficient (Y) of 0.084 g-VSSg-COD-1. The validation of biokinetic parameters based on statistical analysis showed fairly precise results following the trend of experimental data to determine the substrate concentration in the effluent unit. Therefore, the biokinetic values can be applied in the design of ABR post-denitrification using primary sludge incorporation with high strength nitrate.Keywords:  Anaerobic baffled reactor, biokinetics, Contois, hydrolysis, post-denitrification.