The Decreasing Ground Potential Rise by Lessening Soil Resistance in Arrester Grounding System Putra, Dian Eka; Yani, Raden Ahmad; Siahan, Michael Solafide; Rizal, Choirul; Nofiansah, Nofiansah
IJEEIT : International Journal of Electrical Engineering and Information Technology Vol 6 No 2 (2023): September 2023
Publisher : NAROTAMA UNIVERSITY

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29138/ijeeit.v6i2.2180

Abstract

CCR PERFORMANCE AGAINST ILLUMINATION OF AIRCRAFT RUNWAY LIGHTS AT SULTAN THAHA AIRPORT JAMBI Yani, Raden Ahmad; Julianda, Eka Herta; Putra, Dian Eka; Rizal, Choirul; Subianto, Subianto
Jurnal Ampere Vol. 7 No. 2 (2022): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31851/ampere.v7i2.9360

Abstract

Keselamatan pengguna transfortasi sangat penting diperhatikan terutama pada dunia penerbangan konmersil, salah satu faktor pendukung keselamatan terletak pada landasan pacu pesawat terbang atau runway, pengunaan landasan pacu pesawat terbang bukan hanya pada siang hari tetapi juga pada malam hari, untuk pendaratan dan lepas landas pada malam hari diperlukan penerangan pada sisi landasan pacu, penelitian ini sangat penting dikarenakan  penerangan inilah yang menjadi acuan keselamatan penumpang dan transfortasi udara terutama untuk pendaratan pada malam hari dan pada cuaca yang buruk, untuk mempertahankan intensitas penerangan pada landasan pacu diperlukan CCR (Constan Current Regulator) terutama pada keadaan gelap dan berkabut, selain kinerja CCR kinerja kuat penerangan pada lampu landasan pacu perlu dievaluasi untuk keselamatan dan kenyamanan pendaratan pesawat terbang. Maka dari itu pada penelitian ini didapatkan intensitas penerangan tertinggi dengan nilai sebesar 177,1 lux dan arus listrik yang digunakan untuk penerangan landasan pacu pada CCR sebesar 6,6 ampere. 
Perbandingan Daya Hubung Singkat Pada Penyulang 20 Kv Sisi Sekunder Tranformator Daya Ii Di Gardu Induk Bungaran Lubis, Chairunnisa; Balqis, Amirah; Yani, Raden Ahmad; Pratiwi, Dwi
Jurnal Ampere Vol. 9 No. 1 (2024): Jurnal Ampere
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31851/ampere.v9i1.14798

Abstract

Pada pratiknya dilapangan mayoritas jaringan distribusi di PT. PLN (Persero) UID Palembang masih bayakmenggunakan jenis konstruksi radial, dimana selain jenis konstruksi panjang jaringan distribusimempengaruhi jenis-jenis gangguan dalam proses penyaluran energi listrik. Dengan pajangnya jaringantersebut gangguan yang terjadi pada jaringan atau penyulang 20 KV dapat dipisahkan menjadi dua jenisgangguan yaitu gangguan yang bersifat simetris maupun gangguan bersifat asimetris. Atas dasar gangguan tesebut penulis tertarik untuk meneliti dan menganalisa perbandingan besar daya hubung singkat yang terjadi pada penyulang-penyulang dari sisi sekunder transformator daya II pada Gardu Induk Bungaran. Dari hasil penelitian yang dilakukan penulis menyimpulkan bahwa bila terjadi perbedaan besarnya daya hubung singkat pada penyulang-penyulang 20 KV dimana bila lihat dari perbedaan tersebut dapatdiasumsikan bahwa besarnya daya hubung singkat pada penyulang distribusi berbanding terbalik dengan pajang saluran distribusi 20 kV, dimana semakin panjang saluran maka daya hubung singkat lebih kecil dan semakin pendek saluran distribusi 20 kV maka daya hubung singkat akan semakin besar.
Metode Penurunan Resistansi Pentanahan Arrester pada Gardu Distribusi untuk Meminimalisir Terjadinya Ground Potensial Rise (GPR) Sari, Triani Mardalena; Putra, Dian Eka; Yani, Raden Ahmad; Nofiansah, Nofiansah
SURYA TEKNIKA Vol 13 No 1 (2026): JURNAL SURYA TEKNIKA
Publisher : Fakultas Teknik UMRI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37859/jst.v13i1.11219

Abstract

An effective arrester earthing system at distribution substations is crucial for conducting lightning currents to prevent Ground Potential Rise (GPR). Initial measurements at PD.0431 substation showed a resistance of 6.7 Ω, exceeding the PUIL 2020 limit of 5 Ω. This study aims to reduce resistance by adding parallel rod electrodes. Measurements were taken using an Earth Tester with the potential drop method, while GPR, touch voltage, and step voltage analyses were simulated with CYMGrd (1000 A fault current). The results showed that the addition of four electrodes reduced the resistance from 6.08 Ω to 1.97 Ω, meeting the standard. Simulations showed a 52.7% reduction in GPR, a 73.9% reduction in touch voltage, and a 74.7% reduction in step voltage. The post-improvement ground potential contour was also more uniform. This study proves that the parallel electrode configuration effectively reduces resistance while mitigating GPR risks. This method is recommended for substations with similar characteristics.
Evaluasi Sistem Pentanahan Kubikel 20 kV Berdasarkan Standar PUIL 2020 dan IEEE Std 80-2013 Pratama, Yogi Edi; Putra, Dian Eka; Yani, Raden Ahmad
SURYA TEKNIKA Vol 13 No 1 (2026): JURNAL SURYA TEKNIKA
Publisher : Fakultas Teknik UMRI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37859/jst.v13i1.11941

Abstract

The grounding system for the 20 kV switchgear at the Bukit Asam Tanjung Enim town site housing complex (capacity 591,147 kW) plays a crucial role in protecting equipment and personnel from overcurrent faults and touch voltage. This study aims to evaluate the existing conditions, compliance with the PUIL 2020 and IEEE Std 80-2013 standards, factors affecting resistance, and recommendations for improvements. Methods included direct measurements using an ETCR 2100A+ clamp meter, theoretical calculations using the Dwight formula (ρ = 30–35 Ωm), and a comparative analysis of pre- and post-maintenance conditions. The results show that the resistance after maintenance was 0.17–0.91 Ω (average 0.42 Ω), down from 0.91 Ω before maintenance. Theoretical calculations yielded 4.77 Ω (ρ = 30 Ωm). All values were below the maximum limit of 5 Ω, so the system was deemed serviceable and safe. Factors affecting resistance include the condition of the connections, corrosion, soil moisture, and soil resistivity. Routine maintenance proved effective in significantly reducing resistance.