Endah Ariyanti
Pusat Biomedis dan Teknologi Dasar Kesehatan, Jl. Percetakan Negara No. 29, Jakarta

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

CEK SILANG MIKROSKOPIS SEDIAAN DARAH MALARIA PADA MONITORING PENGOBATAN DIHIDROARTEMISININ-PIPERAKUIN DI KALIMANTAN DAN SULAWESI Ariyanti, Endah; E, Riyanti; Prasetyorini, Budi; Aisyah, Aisyah; Khairiri, Khairiri; Harun, Syahrial; Handayani, Sarwo; Tjitra, Emiliana
Media Penelitian dan Pengembangan Kesehatan Vol 22, No 4 Des (2012)
Publisher : Badan Penelitian dan Pengembangan Kesehatan

Show Abstract | Download Original | Original Source | Check in Google Scholar | http://ejournal.litbang.depkes.go.id/index.php/MPK/article/view/2912

Abstract

Abstract Quality assurance of malaria microscopy is an important issue in health service and health research for a better case management. In monitoring Dyhydroartemisinin-Piperaquine, quality assurance was a part of this research activities at sentinel sites in Kalimantan and Sulawesi. This activity was carried out to confirmed diagnosis of malaria cases that could be analysed, and to evaluate the skill of microscopists to be improved in the future. Quality assurance was assessed based on the results of cross-checking malaria smears which done blindly by certified microscopist from Laboratory of  Parasitology ,National Institute of Health Research and Development, The quality of smears were mostly good, however the error rate was still high (10.9%). Therefore, a better and continuing planning and strategiy is needed to improve and mantain the quality  of  skill microscopists. Keywords: malaria; microscopic, Dyhydroartemisinin-Piperaquine   Abstrak Pemantapan kualitas mikroskopis malaria merupakan isue penting dalam pelayanan dan penelitian kesehatan untuk penanganan kasus yang lebih baik. Pada monitoring pengobatan Dihidroartemisinin-Piperakuin, pemantapan kualitas merupakan bagian dari kegiatan penelitian tersebut di lokasi sentinel (Kalimantan dan Sulawesi). Pemantapan dilakukan untuk mendapatkan kepastian diagnosis kasus malaria yang dapat dianalisis, dan sebagai evaluasi ketrampilan mikroskopis untuk perbaikan dan peningkatan di masa datang. Pemantapan kualitas dinilai berdasarkan hasil cek silang sediaan darah malaria secara blinded yang dilakukan oleh mikroskopis tersertifikasi dari Laboratorium Parasitologi Badan Litbang Kesehatan. Hasil cek silang menunjukkan kualitas  sediaan darah sebagian besar sudah baik meskipun untuk error rate masih tinggi mencapai 10,9%. Oleh sebab itu dibutuhkan rencana dan strategi yang baik dan berkelanjutan untuk memperbaiki dan mempertahankan kualitas tenaga mikroskopis malaria yang handal.   Keywords: malaria; mikroskopis; Dihidroartemisinin-Piperakuin
DETEKSI DAN SPESIASI PARASIT MALARIA SAMPEL MONITORING PENGOBATAN DIHYDROARTEMISININ-PIPERAQUINE DI KALIMANTAN DAN SULAWESI: MIKROSKOPIS VS POLYMERASE CHAIN REACTION Herman, Reni; Ariyanti, Endah; Salwati, Ervi; -, Delima; Tjitra, Emiliana
Media Penelitian dan Pengembangan Kesehatan Vol 21, No 3 Sept (2011)
Publisher : Badan Penelitian dan Pengembangan Kesehatan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22435/mpk.v21i3 Sept.91.

Abstract

In monitoring the treatment of malaria with Dihydroartemisinin-piperaquine (DHP), microscopic cross check and Polymerase Chain Reaction (PCR) performed to validate the results of laboratory examinations in the field. This study used finger prick samples from subjects with a diagnosis of malaria in monitoring the treatment of malaria with DHP in Kalimantan and Sulawesi. Samples taken at day 0, blood smears made on slides for microscopic and blood spot on filter paper for PCR examination. The PCR method used is a single-round multiplex polymerase chain reaction that has been modified, the examination of each species carried out in different tubes to distinguish the species P. falciparum or P. Vivax. Target of DNA amplification is a species-specific gene sequences in the small-subunit ribosomal RNA (SSUrRNA), 300 bp for P. falciparum and 276 bp for P.vivax.  P. falciparum and P.vivax identified in 229 samples of blood smears and blood spots. Microscopic and PCR gave the same results, positive 93.4% and negative 6.6% with a sensitivity of  99% and specificity 93.3%. P.falciparum sensitivity and specificity of 92% and 99%, P.vivax 97% and 94%, PCR as a gold standard. There are differences in the results of examination of 5 samples, ie with microscopic examination identified as P.vivax  while the PCR as P. falciparum. In this study, identification of  the microscopic parasite similar to the results of identification by PCR, but differ in determining the types of parasites. In general, the ability to microscopic diagnosis of malaria is very good, but confirmation by PCR is still needed.AbstrakPada monitoring pengobatan malaria  dengan Dihydroartemisinin-piperaquine (DHP),cek silang mikroskopis dan Polymerase Chain Reaction (PCR) dilakukan untuk memvalidasi hasil pemeriksaan di laboratorium lapangan. Penelitian ini menggunakan sediaan darah jari dari subyek dengan diagnosis malaria pada monitoring pengobatan malaria dengan DHP di Kalimantan dan Sulawesi. Sampel diambil pada hari 0, dibuat sediaan apus darah pada kaca benda dan sediaan tetes darah (Blood spot) pada kertas saring. Terhadap sediaan apus darah dilakukan pemeriksaan mikroskopis, dan terhadap sediaan tetes darah dilakukan pemeriksaan PCR. Metode PCR yang digunakan adalah multiplex single round Polymerase Chain Reaction yang telah dimodifikasi, pemeriksaan masing-masing spesies dilakukan pada tabung yang berbeda untuk membedakan spesies P.falciparum atau P. Vivax. Target amplifikasi DNA adalah gen species-specific sequences pada small-subunit ribosomal RNA (SSUrRNA), 300 bp untuk P.falciparum dan P.vivax. P.falciparum dan P.vivax diidentifikasi pada 229 sampel berupa sediaan apus darah pada kaca benda dan blood spot. Hasil identifikasi dengan mikroskopis dan PCR, sampel positif 93,4% dan negatif 6,6% dengan  sensitifitas 99% dan spesifisitas 93,3%. Sensitifitas dan spesifisitas P.falciparum adalah 92% dan 99%, P.vivax 97% dan 94%, dihitung dengan PCR sebagai baku standar. Terdapat perbedaan hasil pemeriksaan terhadap 5 sampel, yaitu dengan pemeriksaan mikroskopis diidentifikasi sebagai P.vivax sementara pada pemeriksaan PCR sebagai P.falciparum. Pada penelitian ini, hasil identifikasi parasit dengan mikroskopis sama dengan hasil identifikasi dengan PCR, namun berbeda pada penentuan jenis parasit. Secara umum kemampuan tenaga mikroskopis pusat untuk menegakkan diagnosis malaria sudah sangat baik, namun untuk penentuan jenis Plasmodium masih memerlukan konfirmasi PCR.