PENGARUH PENGGUNAAN AIR SUHU EKSTRIM SEBAGAI BAHAN PEMBENTUK BETON YANG DITAMBAHKAN ADMIXTURES TERHADAP KUAT TEKAN BETON Aulia, Teuku Budi
Teras Jurnal : Jurnal Teknik Sipil Vol. 10 No. 2 (2020): Volume 10 Nomor 2 September 2020
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v10i2.318

Abstract

Abstrak Perubahan iklim sebagai pemicu pemanasan global merupakan fenomena yang sudah terjadi selama beberapa dasawarsa terakhir. Penggunaan beton sebagai material konstruksi terus meningkat, hampir 60% infrastruktur ketekniksipilan di dunia dibangun menggunakan beton. Penelitian ini bertujuan untuk mengetahui pengaruh pengunaan air bersuhu ekstrim sebagai bahan campuran beton yang ditambahkan admixtures, yaitu accelerator (Sika Cim) dan retarder (Plastiment RTD-01) terhadap kuat tekan beton untuk menghasilkan beton dengan mutu optimal. Air yang digunakan adalah air panas (100ËšC), air dingin (10ËšC), dan air suhu normal (23ËšC). Persentase accelerator dan retarder yang dipakai adalah 0%; 0,25%; 0,50% dan 0,75% dari berat semen dengan faktor air semen (FAS) 0,35; 0,40 dan 0,45. Benda uji silinder standar 15/30 cm berjumlah 135 buah dibuat berdasarkan variasi FAS dan persentase admixtures, masing-masing perlakuan 5 benda uji pada umur pengujian 28 hari. Hasil penelitian menunjukkan beton dengan campuran air suhu ekstrim yang ditambahkan accelerator dan retarder dapat mempengaruhi kuat tekan beton bila dibandingkan dengan beton tanpa menggunakan admixtures. Kuat tekan beton untuk campuran air dingin mengalami peningkatan tertinggi pada FAS 0,35; 0,40 dan 0,45 pada penambahan accelerator 0,25% sebesar 0,119%; 1,226% dan 2,314% dibandingkan campuran air suhu normal tanpa accelerator; sedangkan untuk campuran air panas mengalami peningkatan kuat tekan tertinggi pada FAS 0,35; 0,40 dan 0,45 dengan penambahan retarder 0,25% sebesar 10,345%; 16,076% dan 23,471% bila dibandingkan dengan campuran air suhu normal tanpa penambahan retarder. Analisis varian menunjukkan bahwa penggunaan air suhu ekstrim dengan penambahan admixture mempunyai pengaruh signifikan terhadap kuat tekan beton pada setiap persentase admixtures dengan nilai optimum dicapai pada persentase 0,25%. Kata kunci: Kuat tekan beton, air suhu ekstrim, admixtures, accelerator, retarder Abstract Climate change as a trigger for global warming is a phenomenon that has been occurring in recent decades. The use of concrete as a construction material has been increasing, almost 60% of the world's civil-engineering infrastructures are made of concrete. The aim of this study is to find out the effect of extreme water temperature as mixing water in concrete which is added by admixtures, i.e., accelerator (SikaCim) and retarder (Plastiment RTD-01) on concrete compressive strength and to obtain its optimum value. Water used was hot water (100°C), cold water (10°C), and normal temperature water (23°C). Accelerator and retarder used were 0%; 0.25%; 0.50% and 0.75% by cement weight with w/c-ratio 0.35; 0.40; and 0.45. The specimens were a standard 15/30 cylinder totaling 135 specimens based on variation of w/c-ratio and percentage of admixtures, each variation has 5 specimens and was tested at 28 days. The results showed that extreme water temperature in concrete using accelerator and retarder affected concrete compressive strength compared to normal concrete without admixtures. The highest increase of compressive strength using both cold water and hot water of w/c-ratio 0.35; 0.40; and 0.45 were at 0.25% of admixtures. They were 0.119%; 1.226% and 2.314% for cold water respectively compared to normal mixing water temperature without accelerator, while for hot water were 10.345%; 16.076% and 23.471% respectively compared to normal mixing water temperature without retarder. Varian analysis showed that extreme temperature of concrete mixed water using admixtures has a significant effect of concrete compressive strength at each percentage admixtures with the optimum value reached at 0.25%. Keywords: concrete compressive strength, extreme water temperature, admixtures, accelerator, retarder
PENGARUH DENSITAS ARUS TERHADAP PERILAKU RETAK BETON BERTULANG YANG MENGALAMI KOROSI TULANGAN Amalia, Zahra; Saidi, Taufiq; Aulia, Teuku Budi; Mahlil, Mahlil
Teras Jurnal : Jurnal Teknik Sipil Vol. 11 No. 2 (2021): Volume 11 Nomor 2, September 2021
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v11i2.507

Abstract

Abstrak Korosi pada struktur beton betulang dapat mengurangi kinerja struktur dan umur layannya karena volume tulangan yang berkurang. Besarnya jumlah korosi yang dipengaruhi oleh laju korosi dapat digambarkan melalui besarnya densitas arus yang terjadi. Jumlah korosi yang terjadi mempengaruhi perilaku retak pada beton bertulang, oleh karen itu, pada studi ini dilakukan uji eksperimental untuk mengevaluasi pengaruh densitas arus terhadap perilaku retak permukaan beton dari struktur beton bertulang yang mengalami korosi tulangan. Pengujian dilakukan dengan mengaplikasikan variasi densitas arus yaitu 900 µA/cm2, 500 µA/cm2, 200 µA/cm2 and 100 µA/cm2 pada pengujian korosi secara elektrik menggunakan larutan NaCl sebagai elektrolit untuk menghasilkan ion Cl-. Benda uji yang digunakan adalah balok dengan luas penampang 150x150 mm2 dan panjang benda uji 300 mm. Tulangan baja diameter 19 mm digunakan pada tengah penampang. Hasil pengujian menunjukkan bahwa perilaku retak dari beton bertulang yang mengalami korosi pada tulangannya memiliki kurva yang bilinear. Selain itu, hasil pengujian menunjukkan bahwa densitas arus yang rendah memiliki kecepatan retak permukaan beton yang lebih tinggi jika dibandingkan dengan benda uji dengan menggunakan densitas arus yang tinggi. Kata kunci: korosi, beton bertulang, produk korosi, retak, densitas arus Abstract Corrosion in reinforced concrete structure can reduce structure performance and its service life due to rebar mass loss. Corrosion amount influenced by corrosion rate can be figured out by using current density. Corrosion amount influences the crack behavior of reinforced concrete, therefore, in this study, experimental study was performed to evaluate the effect of current density to surface concrete cracking behavior of corroded reinforced concrete structure. Accelerated corrosion test tests were conducted with various current density. It was 900 µA/cm2, 500 µA/cm2, 200 µA/cm2 and 100 µA/cm2. NaCl solution was used as electrolyte to produce ion Cl-. The specimens were beam with cross section area 150x150 mm2 and 300 mm in length. Rebar with diameter 19 mm was applied in the center of specimen. The results showed that cracking behavior of corroded rebar has bilinear curve that shows the effect of corrosion products movement through cracks. Furthermore, lower corrosion rate has higher cracking speed than higher corrosion rate. Keywords: corrosion, reinforced concrete, corrosion products, cracking, current density