A Review on Strengthening Asset Integrity Management through Risk-Based Inspection In Hydrocarbon Piping Systems Edy Karina; Yudha Pratesa; Johny Wahyuadi Mudaryoto
Recent in Engineering Science and Technology Vol. 4 No. 3 (2026): RiESTech Vol. 4 No. 3 Years 2026
Publisher : MBI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59511/riestech.v4i3.161

Abstract

Hydrocarbon piping systems are critical assets in oil and gas facilities because they operate under pressure, temperature, fluid variability, and corrosive environments that can accelerate material degradation. This study develops a risk-based integrity evaluation framework for hydrocarbon piping systems by integrating corrosion rate assessment, remaining life estimation, and Risk-Based Inspection (RBI) prioritization within an Asset Integrity Management (AIM) perspective. A quantitative case study was conducted using 2025 inspection data from hydrocarbon and utility piping systems at PT X. The evaluation followed the principles of API RP 580 and API RP 581 and used ultrasonic thickness measurement, actual wall thickness, minimum required thickness, corrosion rate, remaining life, Probability of Failure (PoF), Consequence of Failure (CoF), and risk ranking. The results show that most piping systems were categorized as Very Low Risk, while several lines remained in the Medium Risk category. Utility Water Piping had the highest corrosion rate of 0.253 mmpy and the shortest remaining life of 8 years. Hydrocarbon Gas Piping had a lower corrosion rate of 0.076 mmpy and a remaining life of 38 years. The proposed framework strengthens inspection prioritization, risk-based maintenance, and long-term AIM implementation.
Failure Analysis of Economizer Tube Leakage Caused by Localized Internal Corrosion at Weld-Root Regions Dede Ramadhan; Yudha Pratesa; Johny Wahyuadi Mudaryoto
Recent in Engineering Science and Technology Vol. 4 No. 3 (2026): RiESTech Vol. 4 No. 3 Years 2026
Publisher : MBI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59511/riestech.v4i3.163

Abstract

Economizer tube leakage is a common failure in industrial boiler systems and may result in unplanned shutdowns and significant production losses. This study investigates the leakage failure of ASTM A210 Grade C economizer tubes removed from a pulp and paper boiler after long-term service. The investigation combined field inspection, wall-thickness measurements, chemical composition analysis, hardness testing, metallography, and SEM–EDS characterization to determine the degradation mechanism responsible for leakage. Leakage was detected in Tube Row 99 and Tube Row 185 near circumferential and stopper-weld locations. Visual examination revealed that damage was concentrated in the weld-root vicinity, whereas adjacent tube sections remained comparatively unaffected. Thickness measurements showed severe localized wall loss, with the minimum remaining thickness decreasing from 3.00 mm to 1.85 mm. Chemical composition analysis confirmed compliance with ASTM A210 Grade C requirements, while hardness testing showed no evidence of abnormal hardening or thermal degradation. Metallographic examination revealed oxide-layer deterioration and corrosion penetration adjacent to the weld-root interface. SEM–EDS analysis identified corrosion products dominated by iron oxides, confirming an internally initiated corrosion process. Available operating records indicated fluctuations in dissolved oxygen concentration, although the monitoring data were incomplete. The results indicate that excessive weld-root penetration promoted deposit retention and localized environmental variations, creating conditions favorable for oxide-layer deterioration and localized internal corrosion. Progressive wall thinning adjacent to the weld-root region subsequently led to through-wall perforation and leakage. The failure mechanism was identified as weld-root-associated localized internal corrosion, while dissolved oxygen fluctuations were considered a contributing factor to corrosion propagation rather than the primary cause of failure.
A Risk-Based Integrity Management of CO₂ Pipelines in CCUS: Integration of Failure Mechanisms, Risk Assessment, and Inspection Strategies—A Review Risdianto; Johny Wahyuadi Soedarsono; Yudha Pratesa
Recent in Engineering Science and Technology Vol. 4 No. 4 (2026): Articles in Press
Publisher : MBI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59511/riestech.v4i4.167

Abstract

The accelerated deployment of Carbon Capture, Utilization, and Storage (CCUS) systems requires safe and reliable CO₂ transportation infrastructure. Pipelines remain the most feasible option for large-scale CO₂ transport; however, dense-phase thermodynamics, impurity interactions, decompression behavior, and environmentally assisted degradation create integrity challenges that differ from those of conventional hydrocarbon pipelines. This review examines how failure mechanisms, risk assessment methods, and inspection strategies can be integrated into a Risk-Based Inspection (RBI) framework for CO₂ pipelines. Literature was synthesized from studies indexed in Scopus and Web of Science, with emphasis on corrosion, fracture propagation, probabilistic risk assessment, monitoring technologies, and inspection planning. The reviewed evidence indicates that corrosion-related degradation and running fracture are the most critical threats, while probabilistic and reliability-based approaches are increasingly used to address uncertainty. Nevertheless, integration between degradation assessment, risk modeling, and inspection optimization remains fragmented. This paper proposes a dynamic RBI concept that links CO₂-specific degradation mechanisms, Bayesian risk updating, real-time monitoring, and adaptive inspection scheduling. The proposed synthesis supports more reliable, risk-informed integrity management for future CCUS pipeline networks.
EFFECT OF H2O2 AND MnO2 AS OXIDATORS OF GOLD AND COPPER LEACH PROCESSES FROM PRINTED CIRCUIT BOARDS Yudha Pratesa; Aji Wibisono; Wahyuaji Narottama Putra; Yunita Sadeli; A. Zakiyuddin; Sri Harjanto
Jurnal Sains Materi Indonesia Vol. 20 No. 3 (2019): Jurnal Sains dan Materi Indonesia
Publisher : BRIN Publishing (Penerbit BRIN)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17146/jsmi.2019.20.3.4710

Abstract

In general, electronic waste management in the form 2 of printed circuit boards (printed circuit boards/PCBs) is carried out by the process of removing components and taking precious metals that are easily recycled. However, in Indonesia, the recycling process for extracting precious metals has not been much processed, even though they contain precious metals such as copper and gold. This research was conducted to find a more economical and environmentally friendly treatment process by using an oxidizer of Hydrogen Peroxide (H2O2) and Manganese Oxide (MnO2) and reducing the level of HCl used. Observation of metal leaching results using Atomic Adsroption Spectroscopy (AAS) showed the value of recovery (recovery) of gold and copper reached 59.1% and 59.8% for 0.5M HCl + 2.5% H2O2. However, the recovery value of copper has reached its optimum point at the addition of 1.5% H2O2. The use of 3% & 5% MnO2 results in recovery values of 12% and 24% for gold and copper. Observation of the cross section shows the dissolution of the copper metal from the PCB and accompanied by a change in the color of the solution from clear to green, the more concentrated the more the amount of dissolved copper metal shows the characteristic of CuCl solution. The results of the comparison of the two types of oxidizers show that H2O2 is better than MnO2 in producing higher Cu and Au metals more than 3 times.
Metallurgical Investigation of a Modified Eye Bolt Failure Caused by Improper Weld Extension, Specification Deviation, and Crevice Corrosion Fawwaz, Dimas Muhammad; Ulum, Reza Miftahul; Soedarsono, Johny Wahyuadi; Pratesa, Yudha
Journal of Materials Exploration and Findings Vol. 5, No. 2
Publisher : UI Scholars Hub

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

A modified eye bolt from the David Arm Manhole Storage Tank underwent thorough metallurgical study due to the consequences of the bolt's malfunction during operation. Safety issues arose when the manhole door detached during operation. The mechanical testing and chemical composition analysis of the bolts indicated they were manufactured from an ASTM A193 Grade B7 material used for high-temperature bolting. This material did not conform to the engineering drawing, which mentioned SA 563A, which is about nuts, not bolts. This contradiction clearly shows that the eye bolt which was installed does not conform to the intended design. Welded connections of two stud bolts were noted as the origin of the failures in the fractographic analysis. The metallographic pictures justified the observation of individual structures of the weld metal, heat-affected zone, and base metal. The welds had extensive porosities and slag inclusions, which are indicators of poor welds. Moreover, the welds not fully penetrating the metal workpieces also had the effect of reducing the load-bearing area. The joined sections also experienced crevice corrosion, which weakened the whole joint. The combination of poor welds and corrosion, which led to a cross-sectional loss of metal resulted in the eye bolt below the Manhole Door to be suddenly dropped.