Claim Missing Document
Check
Articles

Found 3 Documents
Search

Kadar Glukosa Darah Penderita Tuberkulosis Paru dengan Bakteri Tahan Asam Positif Suharyati Suharyati; S.Y Didik Widiyanto
Jaringan Laboratorium Medis Vol 1, No 1 (2019): May 2019
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jlm.v1i1.5180

Abstract

Pulmonary Tuberculosis is an infectious disease caused by Mycobacterium tuberculosis, Diabetes Mellitus is one of the most common risk factors in pulmonary tuberculosis patients. Pulmonary TB - DM is more severe and chronic than non-diabetic, which can lead to increased susceptibility to tuberculosis bacteria and longer treatment times. Purpose paper’s is knowing the picture of blood glucose in positive pulmonary tuberculosis patients in UP3 Kebumen. The research conducted included descriptive research type. The population of this study were all pulmonary tuberculosis patients with positive smear in UP3 Kebumen in 2017. The sample used was 100 samples, 6 samples had blood glukosa levels ≥ 200 mg / dl, and as many as 4 people blood glukosa levels between 150 - 199 mg / dl. And most have blood glukosa levels between 70 - 149 mg/dl. Pulmonary TB sufferers in UP3 Kebumen are only a few who suffer from Diabetes.
The Study of The Type Laboratory Examination in Health Service Facilities With Integration Determination of Local Content Courses DIII-Health Analyst Kuntjoro Adi Purjanto; S.Y Didik Widiyanto; Teguh Budiharjo
Jaringan Laboratorium Medis Vol 1, No 2 (2019): November 2019
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jlm.v1i2.5466

Abstract

Introduction: Health Laboratory Services is an integral part of healthcare services to the public. The main task of health analyst conducts healthcare laboratory services. In order to produce health analyst personnel who meet the needs of graduates or stake holders, the education will apply the curriculum for the learning process. Diploma in Education 3 students must take at least 108 credits (semester credit unit). Meanwhile, the education core Curriculum 3 medical laboratory technology defined by 82 credits. In order to fulfill the credits set need to be arranged local content to meet the shortage of credits from the core curriculum that is suitable for learning access. Purpose: Obtain the amount of data on the number of laboratory tests and local subjects. Method: Secondary Data from the recording and reporting of each laboratory for 3 months. Results: A total of 48.04% clinical chemical test types. A total of 18.87% hematological examination. A total of 1.88% of parasitological and microbiological examination. A total of 19.54% of immunological examination. The curriculum that is used by the Poltekkes Department of Health analyst Semarang 108 SKS with 82 SKS core curriculum and 26 SKS local payload. The subject or number of face-to-face is based on the data proportion of three large groups of tests, namely clinical chemistry (48.04%). Immunological examination (19.54%) and hematological examination (18.87%). Conclusion: The most proportion of tests on fasyankes are clinical chemistry (48.04%). Courses "Knowledge of materials practice" could be added to the curriculum of the D3 of the Poltekkes health analyst Program in Semarang. Suggestion: Need to calculate the credits and proportion of face to face or depth to the local content course "knowledge of practice materials" and placement in the semester.
Uji MPN Coliform pada Air Isi Ulang dengan Sterilisasi Sinar UV Widodo; Dian Yulia Purwanti; S.Y Didik Widiyanto; Devi Etevia Purlinda
Jaringan Laboratorium Medis Vol 8 No 1 (2026): May 2026
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jlm.v8i1.14460

Abstract

Wolter Refill water typically undergoes a filtration and sterilization process using 254 nm UV light to sterilize against microbial contamination. This bacterial contamination can be tested using the MPN Coliform test, which is the most important microbiological parameter for drinking water quality. Fecal coliform bacteria are the most commonly used microorganisms as indicators of water pollution, as these bacteria are always present in feces. According to Indonesian Minister of Health Regulation No. 492/MENKES/PER/IV/2010, mandatory standards for drinking water quality are regulated, including physical and microbiological requirements. The purpose of this study was to identify the presence of coliform and fecal coliform bacteria in AMIU sold along Jalan Wolter Monginsidi, Semarang, and to analyze their presence in drinking water. The research method was descriptive. The object of the study was AMIU from eight AMIU depots sold along Jalan Wolter Monginsidi, Semarang, while the subjects were coliform and fecal coliform bacteria. The data collected consists of primary data and supporting data which are then arranged descriptively. Research results There are 3 AMIU depots that are positive for containing Coliform bacteria, namely Depot A4, A5 and Depot A8 with a total Coliform bacteria content of 2 MPN / 100 ml. While the 8 AMIU depots studied did not contain fecal Coliform bacteria, namely 0 MPN / 100 ml. The causes of the presence of Coliform bacteria in positive AMIU samples include the sterilization method only using UV light, the sterilization time is less than 1 hour, the sterilization tool is not replaced periodically, the AMIU storage time at the depot is more than 3 days, the gallon is not washed properly, and the AMIU Laboratory is not checked routinely. Poor results in the test are submitted to the depot manager for follow-up by resetting the sterilization tool.