Studi penempatan Circuit Breaker Outgoing (CBO) dan perhitungan relay pada Penyulang Puma berdasarkan pembacaan arus maksimal di Gardu Induk PLN New Bintaro Agusutrisno Agusutrisno; Wahyu Prabowo; Bayu Bagoes Wicaksono
Jurnal Teknika Vol 16, No 1 (2020): Edisi Juni 2020
Publisher : Faculty of Engineering, Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36055/tjst.v16i1.7721

Abstract

Dalam penyaluran listrik seringkali mengalami gangguan atau arus hubung singkat yang disebabkan oleh banyak hal. Dari arus gangguan hubung singkat tersebut akan berdampak pada penurunan kualitas peralatan listrik yang ada di gardu induk maupun gardu distribusi. Untuk itu diperlukannya studi proteksi untuk mengamankan atau melindungi dari gangguan tersebut. Telah berhasil dilakukan studi tentang tentang optimalisasi fungsi circuit breaker outgoing (CBO) sebagai sistem perlindungan pada Penyulang Puma Gardu Induk New Bintaro PLN. Metode yang digunakan adalah metode perhitungan berdasarkan data yang bersumber dari spesifikasi Gardu Induk New Bintaro PLN. Berdasarkan hasil perhitungan arus gangguan hubung singkat, maka CBO harus ditempatkan yaitu 50 % dari panjang Penyulang Puma. Hasil perhitungan pada OCR didapat arus setting primer 157,5 A, nilai konstanta setting 0,143, dan waktu kerja relay 0,297 detik. Sedangkan perhitungan pada ground fault relay (GFR) didapat arus setting primer 41, 506 A, nilai konstanta setting 0,136 dan waktu kerja relay 0,273 detik. Sehingga waktu yang dibutuhkan CBO untuk memutus arus gangguan hubung singkat sangat cepat yaitu untuk arus gangguan hubung singkat 3 phasa sebesar 0,297 detik dan arus gangguan hubung singkat 1 phasa sebesar 0,273 detik. In the distribution of electricity often experience interference or short circuit current caused by many things. The short-circuit fault current will have an impact on the decline in the quality of electrical equipment in substations and distribution substations. For this reason, protection studies are needed to secure or minimize these disturbances. A successful study has been carried out on optimizing the role of circuit breaker outgoing (CBO) as a protection system for the New PLN Bintaro Substations. The method used is a calculation method based on data sourced from PLN New Bintaro Substations. Based on the calculation of the short circuit fault current, then the CBO must be placed at 50% of the length of the puma feeder. The calculation results obtained on the OCR primary setting current 157.5 A, the value of the constant setting 0.143, and the working time of the relay 0.297 seconds. For the calculation on the ground fault relay (GFR), the primary setting current is 41, 506 A, the value of the setting constant is 0.136 and the relay working time is 0.273 seconds. So the time needed for CBO to break the short circuit fault current is very fast, namely for the 3 phase short circuit fault current of 0.297 seconds and the 1 phase short circuit fault current of 0.273 seconds.
Introducing simple farming methods at home for children during a pandemic Ahmad Shulhany; Muhammad Rafi; Ali Akbar; Neisya Linggadhellya Dyva; Nida Amalia; Nina Khoirunisa; Tasya Nur Septi; Arum Febri Nur Hemiyani; Ceri Ahendyarti; Agusutrisno Agusutrisno; Fajri Ikhsan
Journal of Community Service in Science and Engineering (JoCSE) Vol 2, No 1 (2023): Available Online in April 2023
Publisher : Faculty of Engineering, Universitas Sultan Ageng Tirtayasa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36055/jocse.v2i1.19805

Abstract

Children prefer to play games on gadgets rather than explore the environment around the house. This situation is exacerbated by the Covid-19 pandemic that is happening around the world, which has caused the children's play environment to become more limited. The passivity of these children is, of course, very bad for their development and growth. Therefore, it is necessary to introduce fun activities that can be done around the house to avoid the coronavirus. The activity introduced in this community service activity is farming in polybags. The plant introduced was ginger because this plant has many benefits, including as a body warmer. This service activity received a positive response from the children who took part in the event. This introductory activity is expected to raise children's interest in simple farming around the house. Saat ini anak-anak lebih memilih untuk bermain game di gawai dibandingkan dengan melakukan eksplorasi lingkungan di sekitar rumah. Keadaan itu diperparah dengan pandemi Covid-19 yang terjadi di seluruh dunia, yang menyebabkan lingkungan bermain anak menjadi lebih terbatas. Kepasifan anak-anak tersebut tentunya sangat berdampak buruk bagi perkembangan maupun pertumbuhan mereka. Oleh karena itu, diperlukan pengenalan aktivitas yang menyenangkan sekaligus dapat dilakukan di sekitar rumah agar terhindar dari virus korona. Aktifitas yang diperkenalkan dalam kegiatan pengabdian ini adalah bercocok tanam di polibag. Tanaman yang diperkenalkan yaitu jahe karena tanaman tersebut memiliki banyak manfaat, di antaranya sebagai minuman penghangat tubuh. Kegiatan pengabdian ini mendapat respo  positif dari anak-anak yang mengikuti acara. Kegiatan pengenalan ini diharapkan dapat memunculkan ketertarikan anak-anak untuk bercocok tanam secara sederhana di sekitar rumah.