Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Nature: National Academic Journal of Architecture

TINGKAT KEBISINGAN PADA PERUMAHAN BARU DI DALAM KAMPUNG MANGKUKUSUMAN, KOTA YOGYAKARTA Kartika Putri, Tabita Febriawaty; Eddy Prianto
Nature : National Academic Journal of Architecture Vol 9 No 2 (2022): December
Publisher : Department of Architecture, Faculty of Science and Technology, Alauddin State Islamic University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24252/nature.v9i2a6

Abstract

Abstrak_ Rumah tinggal pasca pandemi Covid-19 kini tidak hanya dijadikan sebagai tempat untuk beristirahat, namun juga sebagai tempat untuk bekerja dan juga belajar. Rumah tinggal di area perumahan baru di Mangkukusuman Kota Yogyakarta merupakan area rumah tinggal yang didesain tanpa pertimbangan penanggulangan kebisingan. Penanggulangan kebisingan dapat dilakukan melalui desain bentuk rumah, penempatan denah, maupun pemilihan bahan bangunan yang sesuai untuk mereduksi kebisingan. Penelitian ini bertujuan untuk mengetahui tingkat kebisingan pada sampel rumah di perumahan baru di Mangkukusuman Kota Yogyakarta serta mengidentifikasi sumber-sumber kebisingan yang ada pada area tersebut. Penelitian ini dilakukan dengan melakukan pengukuran kebisingan pada titik-titik tertentu pada sampel rumah yang sudah ditentukan menggunakan Sound Level Meter (SLM). Tingkat kebisingan yang diukur merupakan tingkat kebisingan yang ada pada semua frekuensi (125 Hz – 8000 Hz), sehingga satuan tingkat kebisingan yang digunakan adalah dalam dBA. Kebisingan pada area perumahan baru tersebut bisa melebihi batas nyaman yang ditentukan karena sumber bunyi yang berbeda-beda. Kata kunci : Kebisingan; Rumah Tinggal; Sumber Kebisingan. Abstract_ Residential houses post Covid-19 pandemic are not only used as a place to rest, but also used as a place to work and study. The residential house at a new housing area in Mangkukusuman, Yogyakarta City is a residential area that is/are designed without considering noise management. Noise management can be done through house shape design, floor plans placement, as well as the selection of appropriate building materials to reduce noise. This research aims to determine the levels of noise in sampel houses in new residential area in Mangkukusuman, Yogyakarta City and to identify any sources of noise in the area. This research was conducted by measuring noise at certain points in a predetermined sampel of houses using a Sound Level Meter (SLM). The levels of noise measured are the levels of noise at all frequencies 125 Hz – 8000 Hz, so the unit of the levels of noise that is used is dBA. Noise in the new residential area can exceed the specified comfort limit due to different sound sources. Keywords : Noise; Residential House; Noise Source.
KINERJA TERMAL SERAMBI PADA ARSITEKTUR VERNAKULAR KASUS STUDI: MUSEUM NILA DI PROVINSI RIAU Arman Susilo; Eddy Prianto
Nature : National Academic Journal of Architecture Vol 10 No 1 (2023): Nature
Publisher : Department of Architecture, Faculty of Science and Technology, Alauddin State Islamic University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24252/nature.v10i1a5

Abstract

The Sang Nila Utama museum building is a vernacular architectural form of traditional buildings that have changed from Riau Malay architecture. This shape change certainly affects the thermal performance of the building itself, which in turn will lead to thermal comfort. Comfort is influenced by a) temperature (oC), b) relative humidity (%), c) wind speed (m/s), and d) MRT (mean radiant temperature). This study aims to determine the thermal performance of the building corridor in terms of spatial climatic factors on temperature and humidity. The method used in this study is a quantitative descriptive correlation, measuring variables of temperature and humidity in the museum corridor and interior. The results of research on the temperature variable in 2 (two) days showed a deasedecreasehe the average thermal performance of the microclimate on the porch of 0.2%, which was shown from the + (positive) value, and from the porch to the interior, there was an increase of 1%, which was shown from the value - (negative). From the average value of the temperature variable, the museum is out of a comfortable condition according to SNI T-14-1993-03.