Claim Missing Document
Check
Articles

Found 4 Documents
Search
Journal : Info-Teknik

Studi Kandungan Logam Berat Pb Di Saluran Kenjeran Dan Kerang Di Muara Saluran Rijali Noor
INFO-TEKNIK Vol 4, No 1 (2003): INFOTEKNIK VOL. 4 NO. 1 2003
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/infotek.v4i1.474

Abstract

Kenjeran river is one of the rivers with have estuary to the kenjeran beach which have length a bout 4 km. this river was estimate that has  contaminate by high heavy metal like (Pb). It’s  can effected the contents of heavy metal in the estuary cockle. The research goals is to analysis is there any differentiate the content of heavy metal in the river, analysis the content of heavy metal in the cockle, the water’s quality and the sediment. From the research result showed there is differentiate between the content of heavy metal in the upper course to the estuary. In the upper course, the cockle and the sediment are contaminate by Pb. There are positive interaction between the contents  of Pb in the estuary. The relationship between the content of heavy metal (Pb) in the cockle, the water quality, the sediment and time in the estuary implied as the equation  :Y=1,72-0.24X1+0,0206X2 – 1,23 D1 – 0.289D2.  The goal of management strategy is to increase the environmental quality and to control the pollution with applying the planning concept, management program and monitoring.
T-PIKON-H SEBAGAI TEKNOLOGI ALTERNATIF UNTUK PERBAIKAN SANITASI DI DAERAH SPESIFIK RAWA Rijali Noor
INFO-TEKNIK Vol 12, No 2 (2011): INFOTEKNIK VOL. 12 NO. 2 2011
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/infotek.v12i2.1808

Abstract

Daerah spesifik adalah daerah dimana kondisi geografis/iklim sedemikian rupa sehingga sistem pelayanan sanitasi baik konvensional/non konvensional sulit untuk diterapkan. T-Pikon-H sebagai septic-tank individual dipilih sebagai opsi sanitasi yang cocok diterapkan di daerah spesifik rawa air tawar.Tujuan penelitian: (1) Mengetahui kondisi air, sanitasi, dan kesehatan penduduk Desa Penggalaman; (2) Mengetahui kualitas air rawa tawar di Desa Penggalaman; (3) Bagaimana penerapan T-Pikon-H secara fungsional sebagai septic-tank individual; (4) Mengetahui keefektifan penggunaan kakus T-Pikon-H sebagai septic-tank yang diterapkan di daerah spesifik rawa air tawar Desa Penggalaman di tinjau dari parameter pH, BOD, COD dan colitinja. Penelitian ini bersifat eksperimen skala laboratorium kapasitas 27 liter yang uji cobanya diterapkan di salah satu rumah penduduk di daerah perairan rawa Desa Penggalaman Kecamatan Martapura Barat Kab.Banjar. Pengambilan sampel influent dan effluent dilakukan setelah melewati waktu tinggal 3 hari pada alat hingga 4-5 kali perulangan. Selain itu, penelitian ini didukung dengan data kuesioner untuk mengetahui kondisi air, sanitasi dan kesehatan penduduk Desa Penggalaman pada RT 01,02 dan 03 serta diperkuat adanya uji kualitas air rawa dengan parameter pH, BOD,COD dan colitinja. Hasil penelitian menunjukkan, Desa Penggalaman untuk kondisi air penduduk memperoleh air bersih dari irigasi, pedagang, sungai dan air hujan berturut-turut: 51%, 27%, 9%, 13%. Untuk kondisi sanitasi, jenis kakus yang digunakan 16% kloset siram/leher angsa dan 84% jamban cemplung. Kondisi kesehatan, hampir 73% responden menjawab tidak ada penyakit yang menyerang penduduk Desa, hanya 18% menjawab penyakit kulit, 7% demam biasa, dan 2% diare. Uji kualitas air rawa Desa Penggalaman, dengan pengambilan sampel hulu, tengah, hilir. Nilai pH berturut-turut adalah 5. Nilai BOD berturut-turut 1,44 mg/l; 0,8 mg/l; 0,8 mg/l. Nilai COD berturut-turut 62,18 mg/l; 69,18 mg/l; 64,48 mg/l. Nilai colitinja yang di ukur hanya bagian tengah bernilai 33.000 MPN/100ml. Sesuai PerGub Kal-Sel No.5 Tahun 2007, untuk pH, COD dan colitinja kondisi perairan mengalami penurunan kualitas air. Secara fungsional, dari segi pemasangan, alat T-Pikon-H dapat dipasang di daerah rawa dengan memperhatikan kondisi ketinggian muka air rawa. Dari segi pemakaiannya, tidak ditemukan keluhan berupa bau-bau yang masuk ke dalam rumah.Uji keefektifan T-Pikon-H, diperoleh data untuk pH dari 5 kali pengambilan sampel berturutturut terjadi kenaikan pH yang nilainya 6, 6, 7, 8, 8. Pada data BOD, pengambilan sampel ke-1 influent 5,12 mg/l effluent 11,8 mg/l; sampel ke-2 influent 7,2 mg/l effluent 12,8 mg/l; sampel ke-3 influent 13,6 mg/l effluent 2,56 mg/l; sampel ke-4 influent 3,84 mg/l effluent 1,6 mg/l dan sampel ke-5 influent 2,4 mg/l effluent 4,4 mg/l. Pada data COD, pengambilan sampel ke-1 influent 73,69 mg/l effluent 69,08 mg/l; pengambilan sampel ke-2 influent 76,76 mg/l effluent 82,9 mg/l; pengambilan sampel ke-3 influent 84,44 mg/l effluent 46,06 mg/l; pengambilan sampel ke-4 influent 79,83 mg/l effluent 92,11 mg/l dan pengambilan sampel ke-5 influent 95,95 mg/l effluent 76,76 mg/l. Pada data colitinja, dari 4 kali pengambilan sampel hanya pada pengambilan sampel pertama yang mengalami penurunan jumlah colitinja sampel ke-1 influent > 1.600.000 MPN/100ml effluent 210.000 MPN/100ml. 3 sampel lainnya tidak mengalami penurunan jumlah colitinja. Sehingga keefektifan alat ditinjau dari parameter pH, BOD, COD dan colitinja alat T-Pikon-H belum cukup efektif dalam penurunan parameter tersebut.
Studi Kinerja Teknis Jaringan Distribusi PDAM (Studi Kasus Kota Pelaihari) Rijali Noor; Rony Riduan
INFO-TEKNIK Vol 5, No 1 (2004): INFOTEKNIK VOL. 5 NO. 1 2004
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/infotek.v5i1.654

Abstract

PDAM adalah instansi terkait dalam penyediaan air bersih. Sampai saat ini diestimasi telah banyak terjadi kebocoran dan kehilangan energi dalam jaringan distribusi PDAM, hal ini mengakibatkan kurang optimalnya sistem pelayanan. Sehingga perlu diadakan analisa kondisi jaringan eksisting dari PDAM. Studi kasus diambil adalah daerah Pelaihari.Tujuan studi ini adalah  untuk mengetahui nilai tekan dan flow pada jaringan berdasarkan demand dan dapat diidentifikasi distribusinya pada jaringan distribusi. Metode yang digunakan adalah analisis aliran, tinjauan kehilangan energi utama dan kehilangan akibat sambungan pipa serta analisis jaringan. Hasil dari studi adalah terjadinya kontinuitas aliran terjadi dalam rentang waktu 24 jam pada pipa distribusi saat kondisi ideal. Sedangkan kondisi layanan belum layak pada saat kondisi puncak  karena adanya kehilangan energi.
PEMANFAATAN LIMBAH LUMPUR PD PAL SEBAGAI BAHAN PEMBUATAN PUPUK ORGANIK Rijali Noor; Tri Cahyo Kurniawan
INFO-TEKNIK Vol 15, No 1 (2014): INFOTEKNIK VOL. 15 NO. 1 2014
Publisher : Universitas Lambung Mangkurat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/infotek.v15i1.234

Abstract

Sludge is mud that has particularly the potential use of a very large, PD PAL Banjarmasin manage sewage sludge simply by just piling them in one place. Sludge is a mud that can be processed into organic fertilizer because the sludge contains many microbial decomposer excellent for composting. This study uses sludge as main ingredients are mixed with other additives to be used as organic fertilizer.Composting method is to use the results of an open windrow composting will be tested maturation of the content of N, P, K, the value of C-Organic and C / N ratio and will be compared with SNI 19-7030-2004. The variations include 5 variations with 3 repetitions.Based on the composting time, the most precocious variation is variation of A (without activator) and Variation C (with the addition of Trichoderma sp.) Which for 19 days while the longest is the variation of D (with the addition dectro), while based on the temperature, variations can reaching the highest temperature is in the variation of C (with the addition of Trichoderma sp.) for the content of N, P, K, the value of C-Organic and C / N ratio of all variations still meet the requirements of SNI 19-7030-2004. Of N, P, K, organic-C test and ANOVA using SPSS DMRT test for values of N are the most significant and real different is the variation of B (with EM-4), for which the most significant element of P and E were significantly different in variation (Control), element K is the most significant and significant differences in the variation of B (with EM-4), the value of organic C of the most significant and significant differences in the variation of C (with Trichoderma sp.) and C / N ratio of the most significant and significant differences in the variation of A (without activator) is the best fertilizer variation in terms of the speed of composting and nutrient content is the variation of C with the addition of Trichoderma sp. Keywords: EM-4, Trichoderma sp., Dectro, sewerage, Organic Fertilizer.