Claim Missing Document
Check
Articles

EFISIENSI PEMANFAATAN AIR DENGAN SARANA PENAMPUNGAN AIR HUJAN PADA RUMAH WARGA KOTA KUPANG Krisnayanti, Denik S.; Yosafath, Yoshua T.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 8, No 2 (2019): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (302.576 KB)

Abstract

Kota Kupang memiliki musim hujan yang cukup singkat (3-4 bulan), namun tingkat curah hujan harian tergolong tinggi yakni berkisar antara 79 mm ? 203 mm. Limpasan air hujan yang tinggi dapat dimanfaatkan untuk menunjang kebutuhan air rumah tangga dengan pembuatan sarana PAH. Tujuan dari penelitian ini adalah mengetahui efisiensi pemanfaatan air pada rumah warga dengan memanfaatkan sarana PAH. Metode yang digunakan dalam perencanaan bangunan PAH adalah metode neraca air. Metode ini membandingkan tingkat kebutuhan air (demand) terhadap volume air yang dapat ditampung atau ketersediaan air (supply). Dalam penelitian ini, digunakan 30 sampel untuk mewakili 6 kecamatan di Kota Kupang. Interval kapasitas media penyimpan minimum sarana PAH adalah 26.592? 44.097 liter atau sebesar 26,59-44,10  m3. Berdasarkan hasil perhitungan, dengan memanfaatkan sarana PAH setiap sampel yang dijadikan objek penelitian dapat melakukan penghematan air dengan efisiensi rata-rata sebesar 30,57%. Berdasarkan angka ini, maka dengan adanya bangunan PAH cukup membantu penghematan pengeluaran rumah tangga untuk kebutuhan air bersih.Kupang City have short time of rainy season (3-4 months), butthe value of daily rainwater at Kupang city is classified high drops, that ranges between 79 mm-203 mm. The high amount of rainwater runoff can be utilize to support water domestic needs by build the rooftop rainwater harvesting system. The purpose of this research is to know the efficient of water utilization in citizen?s house by utilize the rooftop rainwater harvesting system. The used method in the rooftop rainwater harvesting system planning is water balance method. This method compares the water demand level to water volume that can be supplied. In this research, 30 samples are used to represent 6 sub-districts in Kupang City. The interval of rooftop rainwater harvesting minimum median capacity is 26.592? 44.097 litre or 26,59-44,10 m3. Based on the calculation result, by utilize the rooftop rainwater harvesting facility on each sample that made as research object can be done by water saving with the average efficiency is 30,57%. Based on this number, then with the exist rooftop rainwater harvesting can help to saving the domestic output for clean water needs too.
PREPARATORY MODULE FOR THE OBJECT-ORIENTED MODELING OF URBAN TERRAIN HYDROLOGICAL RESPONSE Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 2, No 2 (2013): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (150.533 KB)

Abstract

This research aimed at preparing an object-oriented module to use in conjunction with an object-oriented urban terrain hydrological response model. The module serves to capture terrain data and prepare them and make them fit as input to the core part of the urban terrain model. This research had constructed the module. It engages five classes of object, which give it capability to faithfully capturing terrain hydrological features and other relevant data, and arrange them in such a way as to serve as fit input to the core part of the urban terrain model. The module represents an urban terrain by meshing it unto a network of rectangle object elements. In order to overcome edge problems associated with the meshing, utilizing smaller size of elements (hence higher number of elements) and weighted average in terms of ?within a cell contained terrain-sheds areas? were advised. It also strongly encouraged the invention of a more automate ways of terrain data capturing, to replace the manual data entry procedure still utilized in this module.
OBJECT-ORIENTED APPROACH FOR THE ASSESSMENT OF MOMENTCURVATURE RELATIONSHIP OF A VARYING-WIDHT AND MULTI-MATERIAL BEAM CROSS SECTION Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 1, No 2 (2011)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (121.807 KB)

Abstract

This research developed the rational approach to shear design in 1984 Canadian Code Provision into a new approach which is object-oriented in fashion, and presented it for the purpose of assessing moment-curvature-relationship of a varying-width and multimaterial beam cross section. Unlike the traditional method that views a cross section as a single entity, this new approach views a section as a composition of autonomous objects. In this approach, a cross section is recognized as a system which is made up of objects, of which each can be predicated uniquely; behave autonomously in responding to loading, and capable of communication between each other. Being in such a fashion, the approach was shown to be capable to faithfully represent a section which varies in width, and is made up of materials with different mechanical characteristics, in whatever possible arrangement. To compensate for the painstaking computation that may be involved in the approach, and maintain its object-oriented fashion, an-objectoriented computer-software that uses an object-oriented user interface platform was recommended to be provided as an auxiliary to the approach.
PENGARUH PENGGANTIAN SEMEN OLEH ABU SABUT BUAH SABOAK TERHADAP KEKUATAN MORTAR Karya, Muhamad Y.; Hangge, Elsy E.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 7, No 2 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (442.255 KB)

Abstract

Pohon saboak banyak tumbuh di Pulau Timor tetapi masyarakat belum bisa mengolah dengan baik limbah dari buah saboak tersebut. Abu sabut buah saboak diperoleh dari hasil pembakaran sabut buah saboak, dimana memiliki kandungan silikat dan berpotensi untuk dijadikan alternatif sebagai bahan pengganti campuran pembuatan mortar. Tujuan penelitian ini adalah mengetahui sejauh mana pengaruh penggantian semen dengan abu sabut buah saboak terhadap kuat tekan mortar. Penelitian dilakukan dengan membuat benda uji kubus ukuran 5 cm x 5 cm x 5 cm dengan perbandingan penggantian abu sabut buah saboak 0%, 2,5%, 5%, 7,5%, 10% pada campuran mortar. Setiap persentase campuran menggunakan 5 buah benda uji, yang ditinjau pada umur 7 hari, 14 hari, 21 haridan 28 hari. Hasil pengujian kuat tekan beton menunjukkan bahwa nilai kuat tekan optimum terjadi pada komposisi penggantian abu sabut buah saboak 2,5% dengan peningkatan maksimum kuat tekan sebesar 12,72 MPa pada umur mortar 28 hari. Nilai kuat tekan dibandingkan terhadap mortar  normal, mortar dengan tambahan abu sabut saboak 2,5% dapat meningkat sebesar 5,66%. Berdasarkan SNI 03-6882-2002(DPU, 2002) mortar pada penelitian ini tergolong mortar tipe S dengan kuat tekan minimumnya 12,5 MPa, cocok digunakan sebagai bahan pembuat bataringan, batako dan plesteran tembok bagian dalam maupun luar.Saboak trees are grown on Timor Island but the community can not properly cultivate the waste from the saboak fruit saboak. Fibers of saboak husk are obtained from the burning of saboak saber, which has silicate content and has the potential to be used as a substitute for mortar mixture. The purpose of this research is to know how far the influence of cement replacement with saboak husk ash to mortar compressive strength. This research is done by making the cube specimen size 5 cm x 5 cm x 5 cm by using the comparison of saboak saboak root replacement 0%, 2 , 5%, 5%, 7.5%, 10% on the mortar mixture. At each percentage of mixture using 5 test specimens, reviewed at 7 days, 14 days, 21 days and 28 days of mortar age. The result of concrete compressive strength test showed that the optimum compressive strength value occurred in the composition of 2.5% saboak saboak ash substitution with a maximum increase of compressive strength of 12.72 MPa at 28 days of mortar age. The compressive strength value was compared to normal mortar, mortar with 2.5% saboak ash ash can be increased by 5.66%. Based on SNI 03-6882-2002(DPU, 2002) mortar in this research classified mortar type S with minimum compressive strength 12,5 MPa, suitable to be used as material of light brick, brick and plastering of inner and outer wall.
KOMPONEN STRUKTUR BETON DENGAN PERKUATAN EKSTERNAL Nge, Fredi L.; Pah, Jusuf J. S.; Sir, Tri M. W.
Jurnal Teknik Sipil Vol 5, No 1 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (366.319 KB)

Abstract

Struktur beton seperti balok bila memikul beban yang berlebihan atau tidak sesuai dengan perencanaan awal akan menyebabkan struktur beton tersebut mengalami penurunan daya dukung. Hal ini bisa disebabkan apabila suatu bangunan/struktur tersebut mengalami perubahan/alih fungsi dari yang direncanakan sebelumnya. Penelitian ini dilakukan dengan membuat tata cara perencanaan dari perkuatan eksternal kemudian dibuat benda uji di laboratorium yang digunakan untuk memverifikasi hasil desain dari tata cara perencanaan. Hasil desain dengan menggunakan tata cara perencanaan pada balok beton tulangan tunggal dengan perkuatan eksternal, kapasitas balok dalam memikul momen sebesar 4905467,88Nmm. Hasil pengujian lentur balok di laboratorium diperoleh kekuatan rata-rata dari 3 balok uji dalam memikul momen yaitu sebesar 4843750,00 Nmm. Hasil uji statistik Student T Test dengan tingkat kepercayaan 95% tidak terdapat perbedaan yang signifikan antara hasil desain dan hasil pengujian di laboratorium. Dengan menggunakan tata cara perencanaan, maka hasil desain balok beton tulangan rangkap dengan perkuatan eksternal diperoleh kapasitas balok sebesar 6068337,70Nmm. Hasil pengujian lentur dari 3 balok uji memperoleh kekuatan rata-rata balok dalam memikul momen sebesar 6052083,33 Nmm. Hasil uji statistik Student T Test dengan tingkat kepercayaan 95% menghasilkan perbedaan yang tidak signifikan antara hasil desain dan hasil pengujian di laboratorium.
IMPROVING THE EFFICIENCY AND ADEQUACY OF URBAN ROAD-PASSENGER TRANSPORT Pah, Jusuf J.S.
Jurnal Teknik Sipil Vol 1, No 4 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (52.363 KB)

Abstract

This study offered ways to improve the efficiency and adequacy of urban public transport in Kupang, taking as the background the viewpoint that urban transport should concern not only middle and high income people but urban poor as well. It focused on three principle modes of public transport in the city, two of which are formal: city bus, and bemo, and the remaining one is informal/paratransit locally known as ‘ojek’. It took urban transport strategic review published recently by the World Bank as the quarry form which solutions for efficiency and adequacy the city’s passenger-transport were drawn and developed as to suit specific demand of the same. It concluded that to improve the service of public transport in the city, ‘competition-for the-market’ should be introduced into the market of its urban transport form of for-the-market competition recommended are route-concession. It stressed also however that prior to it state-owned motor companies should be privatized, and their capacity to engage in an open competition should be made better. As for bemo, service-contract should be introduced into the relation between the owner and the operators, whereas paratransit should be recognized and regarded as part of the whole urban public transportation system
EVALUASI BATASAN TINGGI MAKSIMUM BANGUNAN TINGKAT TINGGI BERATURAN UNTUK PENERAPAN METODE STATIK EKUIVALEN Pah, Jusuf J. S.; Udiana, I Made; Matarohi, Deddy I.
Jurnal Teknik Sipil Vol 3, No 2 (2014): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (523.141 KB)

Abstract

Dalam penelitian ini dilakukan analisis atas model komputer spesimen struktur bangunan gedung tingkat tinggi menggunakan program komputer: ETABS 2013. Spesimen terbagi ke dalam dua kelompok, spesimen pada kelompok pertama menggunakan sistem rangka (spesimen 9F36) sedangkan pada kelompok kedua menggunakan sistim dinding geser (9SW36). Tinggi awal setiap spesimen adalah 36 m (9 tingkat). Atas setiap spesimen dilandakan 4 akselelogram gempa yaitu El-Centro, Kobe, Chi-Chi Taiwan dan Jepang; dan asesmen untuk mengetahui moda pergoyangan meraka dilakukan. Jika moda pergoyangan yang ditunjukan adalah moda 1 maka satu tingkat (4 m) ditambahkan kepada spesiemen dan akselelogram gempa-gempa dilandakan atasnya dengan cara yang sama seperti sebelumnya, sampai spesiemen menunjukkan pergoyangan dalam moda yang lebih tinggi daripada moda 1. Hasil penelitian ini menunjukkan bahwa spesimen dengan sistem rangka beralih dari bergoyang dalam mode 1 ke mode 2 pada ketinggian 9 lantai (36 m) sedangkan spesimen dengan sistem dinding geser beralih dari bergoyang dalam mode 1 ke mode 2 pada ketinggian 15 lantai (60 m). Terbukti bahwa metoda statik ekivalen dapat diterapkan pada struktur bangunan tingkat tinggi dengan sistem dinding geser yang ketinggiannya melebhi 10 tingkat (40 m) sampai dengan ketinggian 14 tingkat (54 m). Dengan demikian kedalam butir 4.2.1 SNI 1726-2002 perlu integrasikan pembedaan sistem penahan lateral.
PENGARUH VARIASI PERHITUNGAN TEGANGAN DAN REGANGAN KOLOM BETON BERTULANG TERHADAP DAKTILITAS PENAMPANG TAKTERKEKANG Simatupang, Partogi H.; Siallagan, Gisella D.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 7, No 1 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (262.065 KB)

Abstract

Salah satu parameter penting dalam  perencanaan suatu kolom adalah daktilitas.  Nilai daktilitas suatu kolom dapat ditentukan dari kurva hubungan antara momen dan kurvatur. Nilai momen dan kurvatur didapat dari perhitungan tegangan dan regangan beton.Tujuan penelitian ini adalah untuk mengetahui pengaruh variasi tegangan dan regangan kolom beton bertulang terhadap daktilitas penampang tak terkekang. Dalam analisis ini hubungan tegangan dan regangan menggunakan 4 metode yaitu Kent and Park, Popovics, Thorenfeldt dan Hognestad yang kemudian dilakukan analisis momen dan kurvatur secara manual dari hubungan tegangan dan regangan. Selain menghitung secara manual juga digunakan program bantuResponse 2000. Output Response 2000 digunakan sebagai pembanding dengan cara perhitungan manual. Hasil analisis secara manual maupun menggunakan Response 2000 menunjukkan luas tulangan longitudinal dan mutu tulangan longitudinalyang meningkat dapat menurunkan nilai daktilitas kolom sedangkan mutu beton yang meningkat maka daktilitas juga meningkat. Selain itu, konfigurasi tulangan longitudinal juga dapat mempengaruhi nilai daktilitas suatu kolom dengan nilai daktilitas paling kecil terdapat pada sampel UC3-01.One of the important parameter in a column planning is ductility. Ductility of a column can determined from relation curve between moment and curvature.Moment and curvature value is obtained from the calculation of concrete stress and strain.This research aims is to know the effect of stress and strain variation of reinforced concrete column on unconfined section ductility.In this research, stress and strain relation use 4 methods such as Kent and Park, Popovics, Thorenfeldt and Hognestad and then moment-curvature analysis is done manually by Ms.Excel 2013 from stress-strain relation. Besides counting manually also used the Response 2000 program. Output of Response 2000 is used as a comparison by manual calculation. The results of manual analysis or using Response 2000 indicates that an increase in the area of longitudinal reinforcement and the steel yield strength can decreases the ductility while an increase in the concrete strength increases the ductility. In addition, the configuration of longitudinal reinforcement also affects the ductility of a column with the smallest ductility value in the UC3-01.
KOMPOSIT BETON-PROFIL LIP CHANNEL UNTUK MENCEGAH TEKUK LATERAL-TORSIONAL Loe, Ridwan Rinaldo; Pah, Jusuf J. S.; Wahyuningsih, Tri Mardiyati
Jurnal Teknik Sipil Vol 1, No 3 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (121.808 KB)

Abstract

ABSTRACTLip channels profile usually failed before reaching its maximum loaddue to torsional. To avoid this problem, usually lateral support isprovided to the profile. One of the solution is by filling the profile withconcrete material (composite). The purpose of this research is to knowthe bending strength ratio of lip channels profile to lip channels-concretecomposite. The specimens in this research is lip channelsC85x40x8x0.90, C85x40x8x0.65, C75x40x10x0.75, C75x40x10x0.65and two pieces of composite beams of 85x40x1100 mm with two piecesof composite beams 75x40x1100 mm. Beside the bending strength testas the main test, additional test should be runned by concretecompression test using 12 pieces of 150x150x150 cube and 12 pieces oflip channels. Based on this research, it is found that the bending strengthof the lip channels (P-1) and composite beam (K-1) are 262.06 MPa and366.35 MPa each. The result means that there is 1.40 (39.80%)increasing in bending strength. For P-2 the bending strength is 268.64MPa while K-2 is 453.60 MPa or increased 1.69 (68.85%). For P-3bending strength is 180.90 MPa while K-3 is 364.75 MPa, increased 2.02(101.63%). For P-4 the bending strength is 207.59 MPa while K-4 is430.05 MPa, increased 2.07( 107.16%). ABSTRAKUmumnya profil lip channel mengalami kegagalan sebelum mencapaibeban maksimum karena lebih dahulu mengalami puntir. Untukmencegah hal tersebut, diberi sokongan lateral pada profil. Alternatifyang ingin diteliti yaitu dengan cara mengisi material beton (komposit).Tujuan dilakukannya penelitian ini adalah untuk mengetahui besarnyaperbandingan kapasitas lentur profil lip channel dengan komposit betonprofillip channel. Benda uji dalam penelitian ini berupa profil lipchannel C85x40x8x0,90, C85x40x8x0,65, C75x40x10x0,75,C75x40x10x0,65 dan balok komposit dengan ukuran 85x40x1100 mmsebanyak 2 buah, serta 75x40x1100 mm sebanyak 2 buah. Disampingpenelitian utama yaitu pengujian kapasitas lentur profil lip channel danbalok komposit, dilakukan pengujian tambahan, diantaranya untukmengetahui mutu beton maka dilakukan pengujian kuat tekan betondengan benda uji kubus berukuran 150x150x150 mm sebanyak 12 buahdan pengujian kuat tarik profil lip channel untuk mengetahui besar kuattarik profil sebanyak 12 sampel. Berdasarkan hasil penelitian diperolehkapasitas lentur pada baja profil yang tidak dicor beton (P-1) dan yangdicor beton (K-1) masing-masing sebesar 4000 N dan 12000 N. Dengandemikian terjadi peningkatan 3,00 kali atau 200,00%. Untuk P-2kapasitas lenturnya 3000 N sedangkan K-2 13000 N atau mengalamipeningkatan sebesar 4,33 kali (333,33%). Untuk P-3 kapasitas lenturnya2000 N sedangkan K-3 9000 N sehingga mengalami peningkatan 4,50kali (350,00%). Untuk P-4 nilai kapasitas lenturnya 2000 N sedangkanK-4 10000 N sehingga mengalami peningkatan 5,00 kali (400,00%).
KUAT GESER KOMPOSIT BAJA – BETON DENGAN VARIASI BENTUK PENGHUBUNG GESER DITINJAU DARI UJI GESER MURNI Lahamukang, Krisantus M.; Pah, Jusuf J. S.; Messah, Yunita A.
Jurnal Teknik Sipil Vol 3, No 1 (2014): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (754.288 KB)

Abstract

Composite plan assumes that steel and concrete collaborating in bearing the working burden; this will result in a more economical profile design. Besides, the composite structure also has several advantages, such as stronger and more rigid than the non-composite structure. To ensure coherency between the concrete and steel beams, it must be installed a shear connector device on the steel that connected with concrete. The purpose of this study was to determine which shear connector’s strength is stronger; especially the Stud type shear connector with steel quality of 305,17 MPa and the L type shear connector with steel quality of 406,10 MPa. Specimens used were steel-concrete composite with a length of 200 mm, width 164 mm and height of 280 mm with the quality of two types of concrete quality which are 17 MPa and 20 MPa, the composite specimens using two types of shear connector, which are Stud type shear connector and L type shear connector. Concrete mixture planning refers to SK SNI T-15-1990-03. Result of this study shows that stud type shear connector form strongly resists the shear of a steel composite as much as 26,50 KN for concrete quality of 17 MPa and 33,83 KN for concrete quality of 20 MPa.