Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : International Journal of Applied Technology Research

Simulation Data Acquisition and Control for LNG Custody Transfer Based on ISO 8943 Muhammad Arman; Edi Wahyu Sri Mulyono; Muhamad Anda Falahuddin; Wirenda Sekar Ayu
Jurnal Internasional Penelitian Teknologi Terapan Vol 2 No 1 (2021): April 2021
Publisher : Bandung State Polytechnic (Politeknik Negeri Bandung)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35313/ijatr.v2i1.45

Abstract

Liquefied Natural Gas (LNG) is a complex mixture of low-molecular-weight hydrocarbons with nitrogen as a principal inert impurity. Nowadays, the instrumentation control tools are needed in LNG Commercialization to ensure the LNG is safely transported, while minimizing the energy losses across the network. This research was a preliminary design that used LNG custody transfer control tools referred the ISO 8943:2007 standard. The temperature was measured by thermocouple (Rosemount transmitter 3144 series), while the pressure was measured using pressure transmitter (Rosemount transmitter 3051 series). The simulated signal temperature was done by temperature control box, while the simulated pressure was represented by WIKA pressure calibrator. Data from transmitter was sent to the LabVolt 9063 series that has data acquisition for Software Development Kit (SDK) enabled. Previously, the LabVolt 9063 did not recognized the signal from the transmitter. The SDK software bridged the LabVolt hardware with the LabView software. In the simulated system, temperature alarm will be triggered when the temperature value exceeds 20oC. For simulated pressure, the alarm will respond if pressure value exceeds 30 psi. From the results of this research, the communication between hardware and software worked properly. The data acquisition system was stable during the data collection stage, processing and displaying. In addition, the alarm indicator for both temperature and pressure was met within the threshold value.
Experimental Investigation on PM10 and PM2.5 Concentrations in North Bandung Wellid, Ismail; Nurfitriani, Nita; Falahuddin, Muhamad Anda; Simbolon, Luga Martin; Sunardi, Cecep; Nuryati, Neneng; bin Sukri, Mohamad Firdaus
Jurnal Internasional Penelitian Teknologi Terapan Vol 4 No 2 (2023): October 2023
Publisher : Bandung State Polytechnic (Politeknik Negeri Bandung)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35313/ijatr.v4i2.124

Abstract

North Bandung is an area where there are several tourist attractions, including the Dago Dream Park. The main road to several locations in North Bandung is via the road in front of Terminal Dago. For this reason, the purpose of this study was to collect data on PM2.5 and PM10 concentrations at both locations, namely in front of Terminal Dago and Dago Dream Park. Data collection was carried out for seven days, from Monday to Sunday, from 08.00 to 16.00 local time. To evaluate air quality in these two places, the national standard, namely PPRI No. 22 of 2021 and international standards from WHO were applied. The measurement results show that the concentrations of PM2.5 and PM10 in these two locations are still within the national standard. Meanwhile, when evaluated with WHO standards, PM10 concentrations in both locations are still within standard, but for PM2.5, there are several days where the air quality is out of the standard. The average concentrations of PM2.5 and PM10 during the 7 days of measurement at Terminal Dago are 19.9 μg/m3 and 21.6 μg/m3, respectively. While the average concentration of PM2.5 and PM10 during 1 week of data collection were 18.9 μg/m3 and 19.9 μg/m3, respectively. This means that the concentration of PM2.5 and PM10 at Terminal Dago is slightly higher than that of at Dago Dream Park. In addition, based on an evaluation using national standards, Dago Dream Park tourist attractions still have good air quality and are safe for local residents and tourists. From the data recorded at the Health Centre (Puskesmas), the number of ARI cases in the two locations in 2020 and 2021 is relatively not much different.