Claim Missing Document
Check
Articles

DEGRADASI SENYAWA IMIDAKLOPRID SECARA ADVANCED OXIDATION PROCESSES DENGAN PENAMBAHAN TIO2-ANATASE Amelia, Fitrah; -, Safni; Suyani, Hamzar
Jurnal Riset Kimia Vol 8, No 2 (2015): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v8i2.225

Abstract

Imidacloprid is active compounds in Confidor 200 SL with  have toxical character. Degradation of Imidacloprid in Advanced Oxidation Processes (AOPs) method by using TiO2 catalyst can reduce toxic level. Advanced Oxidation Processes (AOPs) method which is used is Sonolysis, Photolysis, and Ozonolisis. The result of sonolysis, Photolysis, and Ozonolysis measured by spectrophotometer UV-Vis with λ 400-600 nm, and than optimum degradation waste after addition of catalys measured by HPLC. The result of degradation of Imidacloprid 6 mg/L using sonolysis without addition catalys is more smallest from addition catalys which degradated in 60 minute, temperature 25±1 °C. At the same time with Photolysis methode for addition catalys we get the degradation is more biggest from addition catalys. Degradation percentage of imidacloprid without addition of TiO2-anatase reach is small from with addition of TiO2. Measure using HPLC for each methode we get more than one peak in chromatogram. It means there are other coumpounds in imidacloprid solution.
STUDI OPTIMASI PENENTUAN Cu(II) DENGAN MENGGUNAKAN KALKON SEBAGAI PENGOMPLEK SECARA VOLTAMMETRI STRIPPING ADSORPTIF (AdSV) -, Deswati; Suyani, Hamzar; Arifin, Bustanul; -, Imelda; Salamah, Yunita
Jurnal Riset Kimia Vol 4, No 2 (2011): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v4i2.131

Abstract

 ABSTRACT The research about determination of Cu(II) by adsorptive stripping voltammetry (AdSV) was conducted. AdSV method was applied to the determination of copper in ultra trace concentration. The parameters of ligand, accumulation potential, accumulation time, pH and ligand concentration was studied. Calcon was found as complexing agent that give the highest peak current. The optimum condition are accumulation potential -0,7 V, accumulation time 60 s, pH 10, and calcon concentration 0.12 mM. The relative standar deviation (n=8) at 10 µg/L standard concentration were obtained 4,27 %. This method was applied to determination of Cu(II) in sample from Batang Air Dingin, Lubuk Minturun and Muara Padang. The sample concentration were 4,778 µg/L and 5,189 µg/L for Batang Air Dingin and Muara Padang, respectively. The recovery of this method was studied for sample from Muara Padang and 98,31 % was obtained. Key words :   Adsorptive, Stripping, Voltammetry, Calcon and Copper    
PENARIKAN ION Cu2+ (CuSO4) DARI LARUTAN AIR MELALUI PROSES ELEKTROLISIS SECARA FOTOVOLTAIK DENGAN SEMIKONDUKTOR LAPISAN OKSIDA CuO DAN ZnO DARI KUNINGAN Alif, Admin; Suyani, Hamzar
Jurnal Riset Kimia Vol 5, No 2 (2012): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v5i2.222

Abstract

Photovoltaic is a method that can convert sunlight energy into electrical energy. One use ofphotovoltaic electrolysis can be used for metal ions contained in the liquid waste. The research aims electrolyzing Cu2+ ions from aqueous solution using a series of photovoltaic cells with semiconductor CuO and ZnO oxide layer of brass with Na2SO4 electrolyte. The series of photovoltaic cells is associated with an electrolysis cell containing Cu2+ ions to be electrolysed. Semiconductor electrodes made with brass burning in a furnace in a few repetitions at a temperature of 400°C for 1 hour. U-shaped electrolysis cells glass tube containing a solution of CuSO4 1.25 g/L using a carbon rod as anode and cathode. Electrolysis of Cu2+ ions results were analyzed by Atomic Absorption Spectrofotometer (AAS). The results showed that the optimum conditions Na2SO4 electrolyte concentration 0.8 N with semiconductor double-furnace with a strong current 0.829 mA and a voltage of 0.241 mV, the value of efficiency of conversion of solar energy into electrical energy is 0.599%. Electrolysis of Cu2+ ions for 4 weeks could reduce Cu2+ ions concentration of 35 mg/L to 15.909 mg/L (45.45%). CuO and ZnO electrodes was relatively less stable and cause strong currents and voltage drop along the length of the process.
DEGRADASI SENYAWA DIKOFOL DALAM PESTISIDA KELTHANE 200 EC SECARA FOTOLISIS DENGAN PENAMBAHAN TiO2-ANATASE -, Safni; -, Desmiati; Suyani, Hamzar
Jurnal Riset Kimia Vol 2, No 2 (2009): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v2i2.154

Abstract

  ABSTRACT This research is conducted to know whether dicofol compound in Kelthane 200 EC pesticide can be degraded with photolysis method by adding TiO2-anatase. Photolysis method is conducted by using UV 10 watt lamp at the wavelength of 365 nm. The result shows that photolysis method could degrade the dicofol compound at 30 mg/L concentration as 9.73% after 60 minutes irradiation. Paraquat compound with the similar concentration by adding 30 mg unmixed TiO2-anatase could degradade 32.51% after 60 minutes irradiation and 65.84% by mixing TiO2-anatase. Furthermore, dicofol with the same concentration and TiO2-anatase addition could 86.13% after 180 minutes irradiation. Keywords : degradation, photolysis, dicofol, anatase-TiO2   
PEMBERIAN FLY ASH (ABU SISA BOILER PABRIK PULP) UNTUK MENINGKATKAN pH TANAH GAMBUT -, Rini; Nurdin, Hazli; Suyani, Hamzar; Prasetyo, Teguh B.
Jurnal Riset Kimia Vol 2, No 2 (2009): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v2i2.153

Abstract

Vol. 2, No. 2ABSTRACT The research of fly ash as ameliorant to decrease the humic acid in peat soil of Rimbo Panjang, Riau. It is found that fly ash  at 10 ton/Ha showed the best result decresing pH of peat soil (4.4 to 6.36) and humic acid content (0.2923 g/g to 0.0972 g/g). Keywords: fly ash, peat soil, pH, humic acid   
STUDI OPTIMASI PENENTUAN KADMIUM(II) SECARA VOLTAMMETRI STRIPPING ADSORPTIF Deswati, Deswati; Suyani, Hamzar; Buhatika, Citra
Jurnal Riset Kimia Vol 3, No 2 (2010): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v3i2.37

Abstract

  ABSTRACT Study of optimation cadmium(II) by adsorptive stripping voltammetry has been done. The aim of this study to get optimum conditions for determination of Cd(II). Parameters were done : potential accumulation, time accumulation, pH, supporting electrolite concentration and optimum of complex concentration. In this case, the optimum conditions were reached in potential accumulation -0.7 V, time accumulation 60 second, pH 7.0, NH4Cl 0.12 M, calcon concentration 0.12 mM. In the optimum condition was obtained with the relative standard deviation was 4.61% for eight replicates, measurements of 0.01 ppm. The method was applied to the direct determination of Cd(II) in water around Batang Air Dingin Lubuk Minturun and Muara Padang. Concentration Cd(II) in sample was equal to 7.359 μg/L and 3.659 μg/L with recovery of 99.04%. Keywords: cadmiun, adsorptive, stripping, voltammetry
THE OPTIMATION SIMULTANEUOS DETERMINATION OF LEAD(II) AND CADMIUM(II) BY ADSORPTIVE STRIPPING VOLTAMMETRY (ADSV) -, Deswati; Suyani, Hamzar; Loekman, Umiati; Sari, Nilam
Jurnal Riset Kimia Vol 5, No 2 (2012): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v5i2.198

Abstract

A selective and sensitive adsorptive stripping voltammetric (AdSV) method for simultaneous determination of lead(II) and cadmium(II) were proposed. The aim of this study was to get the optimum condition for simultaneuos determination of lead(II) and cadmium(II). The parameters were studied such as: variation of accumulation potential, accumulation time, pH, and variation ofcalcon concentration. In this case, the optimum conditions were reached at accumulation potential –0.7 V, accumulation time 80 s, concentration of 0.12 mM calcon, and pH 7.0. At the optimumconditions the relative standard deviation were 2.90% and 1.46% for Pb(II) and Cd(II) respectively for eight replicates (n = 8) measurements. The method was applied for the direct determination of Pb(II) and Cd(II) in sea water around Bungus, Padang City. Concentration Pb(II) and Cd(II) insample were 9.918 μg/L – 27.320 μg/L for Pb(II) and 7.997 μg/L - 32.521 μg/L for Cd(II), with recovery of 99.48%, and 103.28 for Pb(II), and Cd(II) respectively.
DEGRADASI SENYAWA PARAQUAT DALAM PESTISIDA GRAMOXONE® SECARA SONOZOLISIS DENGAN PENAMBAHAN TiO2-ANATASE Yenni, Neila; Safni, Safni; Suyani, Hamzar
Jurnal Riset Kimia Vol 3, No 2 (2010): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v3i2.58

Abstract

 ABSTRACT Degradation of Paraquat compound in Gramoxone pesticide had been done by sonolysis, ozonolysis, and sonozolysis. Sonolysis methods were performed using an ultrasound VC-1, ozonolysis using a bio-ozone space age sterilizer, and sonozolysis by combining sonolysis and ozonolysis methods. The optimum condition for degradation of 4 mg/L paraquat by sonolysis was found at temperature 40±1°C. Percentage of degradation at optimum condition was 22.80% with 90 minutes treatment. Whereas, with using ozonolysis method percentage of degradation of paraquat 4 mg/L was 50.39% with 60 minutes treatment. The combination of sonolysis and ozonolysis method simultaneously, these so-called sonozolysis, for degradation of the same compound, extend the percentage of degradation to 45.87% with only 30 minutes treatment. Keywords: Paraquat, Sonolisis, Ozonolisis
ANALISIS SEBARAN LOGAM BERAT PADA ALIRAN AIR DARI TEMPAT PEMBUANGAN AKHIR (TPA) SAMPAH AIR DINGIN -, Fatmawinir; Suyani, Hamzar; Alif, Admin
Jurnal Riset Kimia Vol 8, No 2 (2015): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v8i2.224

Abstract

Final Disposal of waste at Air Dingin Padang City using open dumping system is expected to negatively affect the groundwater and surrounding waterways. Research on the content of heavy metals in landfill water flow in the Air Dingin were made in 2 (two) times that were before the rain and after the rain, then the results were compared with the applicable standard. The content of heavy metals Pb, Cu, Zn, Cd and Mn in Final Disposal (TPA) of waste at Air Dingin Padang City were 0.01-0.17 mg/L,  0.005-0.025 mg/L, 0.0-0.7254 mg/L,  0.0-0.011 mg/L, dan  0.0-0.966mg/L. Pb concentration exceeded the quality standard KEPMEN LH 51 in 1995 leachate pond, while the flow of water and monitoring wells Pb metal content exceeds the quality standards PP.RI.No.82 on 2001 and Mn outlet river  exceeds the quality standards PP.RI.No.82 on 2001. In population of all heavy metals well below the quality stanadard PP.RI.No.82 on 2001. The content heavy metals was affected by the distance of the location of waste, the pH value and after of the rain water around the landfill waste.
KARAKTERISASI EKSTRAK DAUN DEWA (Gynura pseudochina (L.) DC) DENGAN KROMATOGRAFI CAIR KINERJA TINGGI Rivai, Harrizul; Nurdin, Hazli; Suyani, Hamzar; Bakhtiar, Amri
JFIOnline | Print ISSN 1412-1107 | e-ISSN 2355-696X Vol 5, No 3 (2011)
Publisher : Indonesian Research Gateway

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Extract of god leaves [Gynura pseudochina (L.) DC] has been characterized by using the high performance liquid chromatography method (HPLC). Dried god leaves were extracted by 70% ethanol and followed by fractionation successively with hexane, ethyl acetate, butanol and water. Fractions of ethyl acetate, butanol and water were dissolved in methanol respectively and injected into HPLC system which is optimized previously. Profiles of respective fractions showed a number of specific peaks that can be used to identify and control the quality of god leaves extract.   ABSTRAK Karakterisasi ekstrak daun dewa [Gynura pseudochina (L.) DC] telah dilakukan dengan menggunakan metode kromatografi cair kinerja tinggi (KCKT). Daun dewa kering diekstraksi dengan etanol 70% dan kemudian difraksinasi berturut-turut dengan heksana, etil asetat, butanol dan air. Fraksi-fraksi etil asetat, butanol dan air dilarutkan dalam metanol dan diinjeksikan ke sistem KCKT yang telah dioptimasi sebelumnya. Pola KCKT masing-masing fraksi menunjukkan puncak-puncak khas yang dapat dipakai untuk identifikasi dan pengendalian mutu ekstrak daun dewa.