Claim Missing Document
Check
Articles

Found 4 Documents
Search

Rancang Bangun Alat Ukur Pollutant Standard Index yang Terintegrasi dengan Pengukuran Faktor-Faktor Cuaca Secara Real Time Isnaini, Vandri Ahmad; Wardhana, Indrawata; Wirman, Rahmi Putri
Jurnal Ilmu Fisika Vol 7, No 2 (2015): JURNAL ILMU FISIKA
Publisher : Jurnal Ilmu Fisika

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (346.459 KB) | DOI: 10.25077/jif.7.2.63-68.2015

Abstract

Telah dilakukan penelitian tentang perancangan dan pembuatan alat ukur Pollutant Standard Index (PSI) yang terintegrasi dengan pengukuran faktor – faktor cuaca secara real time. Alat ukur  menggunakan basis  mikrokontroller arduino mega ADK. Sensor gas MQ-135 dan MQ-7 digunakan untuk pengukuran indeks polusi udara  sedangkan untuk pengukuran faktor cuaca digunakan sensor DHT-11 dan DFR0026. Sistem ini juga ditambahkan GPS shield untuk penentuan lokasi pengukuran secara real time. Hasil  pengukuran disimpan ke dalam sistem database komputer yang terhubung melalui kabel USB. Penelitian  terdiri atas perancangan hardware, perancangan software, dan  tahap pengujian keseluruhan dari sistem alat ukur. Data yang dapat diukur oleh alat  adalah data tingkat polusi udara, suhu udara, kelembaban udara dan intensitas cahaya. Tahap pengukuran lapangan dilakukan di area sekitar IAIN Sulthan Thaha Saifuddin Jambi dan Universitas Jambi. Analisis perhitungan memperlihatkan  tingkat polusi udara sangat mempengaruhi temperatur udara suatu wilayah.  Semakin tinggi tingkat polusi udara, maka temperatur udara di wilayah tersebut akan semakin tinggi. Tingkat polusi udara tidak memiliki pengaruh yang signifikan terhadap kelembaban dan intensitas cahaya.
Kajian Tingkat Akurasi Sensor pada Rancang Bangun Alat Ukur Total Dissolved Solids (TDS) dan Tingkat Kekeruhan Air Wirman, Rahmi Putri; Wardhana, Indrawata; Isnaini, Vandri Ahmad
Jurnal Fisika Vol 9, No 1 (2019)
Publisher : Universitas Negeri Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15294/jf.v9i1.17056

Abstract

Total Dissolved Solids (TDS) and turbidity of water are parameters to determine the quality of water. In this research, instruments development and study of accuracy level for TDS meter and turbidimeter have been made. Instruments were made using TDS sensor and turbidity sensor that were inexpensive and available on the market. The samples used for instruments examination were water with dye (Rhodamine B) and powder of coffee as impurities. The results showed that the sensors worked properly and provided a better accuracy in measuring water samples with coffee impurities than dye impurities. The inaccuracy on the determination of water samples with dye impurities due to dye particles which have soluble properties on water and microscopic size than particles of coffee.
Addressing Missing Data in Environmental Technologies: Economic and Environmental Optimizing Air Quality Monitoring with Random Forest and MissForest Nengsih, Titin Agustin; Wardhana, Indrawata; M. Nazori Madjid, M. Nazori
Jurnal Riset Teknologi Pencegahan Pencemaran Industri Vol. 16 No. 1 (2025): May
Publisher : Balai Besar Standardisasi dan Pelayanan Jasa Pencegahan Pencemaran Industri

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21771/jrtppi.2025.v16.no1.p23-31

Abstract

Air quality monitoring often encounters missing data issues due to technical glitches, equipment malfunctions, or other causes. This study employs PM2.5 and PM10 datasets from station 6, calculating multiple weighted probabilities for imputation. With missing values introduced at rates of 10, 40, and 70 percents through different amputation methods, the Random Forest and missForest techniques are utilized for imputation. Notably, missForest consistently outperforms Random Forest across all scenarios, yielding accuracy exceeding 96% even with high missing data levels. MissForest achieves remarkable accuracy above 96% for PM2.5 and PM10 across left, middle, and right multiple weight probabilities amputations. Overall, missForest attains the highest accuracy (over 97%) for Air Quality Index at lower and middle missing value proportions.
PENILAIAN KESEHATAN MULTIDOMAIN BATERAI LITHIUM-ION UNTUK SISTEM DIRGANTARA BERBASIS PRINCIPAL COMPONENT ANALYSIS (PCA) DAN K-MEANS Wardhana, Indrawata; Isnaini, Vandri Ahmad; Wirman, Rahmi Putri; Junjunan, Soleh Fajar; Mursyitah, Dian; Parmo, Parmo
JOURNAL ONLINE OF PHYSICS Vol. 12 No. 1 (2026): JOP (Journal Online of Physics) Vol 12 No 3
Publisher : Prodi Fisika FST UNJA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22437/h40b6971

Abstract

Baterai lithium-ion pada sistem dirgantara bekerja sebagai subsistem penyimpanan energi yang harus mempertahankan ketersediaan daya, kestabilan operasi, dan keandalan selama siklus penggunaan. Dari sudut pandang fisika, penuaan baterai merupakan perubahan bertahap pada respons listrik, termal, waktu pelepasan, dan proses elektrokimia sehingga tidak selalu dapat direpresentasikan hanya melalui penurunan kapasitas. Penelitian ini mengembangkan pendekatan penilaian kesehatan multidomain menggunakan empat sel National Aeronautics and Space Administration (NASA)  Ames Battery Aging, yaitu B0005, B0006, B0007, dan B0018. Tujuh besaran hasil pengukuran siklus digunakan untuk membentuk representasi kondisi baterai yang mencakup kapasitas, tegangan, temperatur, durasi pelepasan, dan resistansi transfer muatan (R_ct). Principal component analysis (PCA) digunakan untuk mereduksi ruang pengamatan, sedangkan K-means digunakan untuk mengidentifikasi beberapa rezim kondisi dengan jumlah kluster K=2–5. Selanjutnya, Multi-Domain Health Index (HI) digunakan untuk menggambarkan tingkat degradasi secara kontinu, sementara R_ct dikaji sebagai besaran elektrokimia untuk prognosis. Dua komponen utama mempertahankan lebih dari 90% variansi pada seluruh sel. Hasil menunjukkan bahwa pendekatan multidomain mampu menghubungkan besaran fisis yang terukur dengan kondisi baterai secara lebih komprehensif. Kerangka ini memberikan dasar interpretasi yang menggabungkan fisika baterai, pengukuran instrumentasi, karakterisasi kondisi, dan kebutuhan pemantauan kesehatan baterai pada sistem