Identifikasi Potensi Bahaya pada Keamanan, Keselamatan, Kesehatan Kerja, dan Lingkungan (K3l) di Gardu Induk Balaraja Lama Menggunakan Metode Hirarc (Hazard Identification, Risk Assessment, Risk Control) Muhamad Putra Dermawan; Belinda Ayuningtyas
Venus: Jurnal Publikasi Rumpun Ilmu Teknik  Vol. 4 No. 3 (2026): Juni: Venus: Jurnal Publikasi Rumpun Ilmu Teknik
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/venus.v4i3.1474

Abstract

Substations are critical components of electrical power systems but pose significant occupational safety risks due to medium-voltage equipment operation. This study aims to identify potential hazards and analyze Occupational Safety, Health, and Environment (K3L) risks at the Balaraja Lama Substation based on electrical testing of the Algojo Feeder using the Hazard Identification, Risk Assessment, and Risk Control (HIRARC) method. Hazard identification was conducted through field observations, visual equipment inspections, and electrical tests, including circuit breaker (PMT) contact resistance and AC/DC power supply polarity measurements. The PMT contact resistance values were 92.5 µΩ (R), 60.2 µΩ (S), and 98.6 µΩ (T), meeting IEC 62271 and IEC 60694 standards. The power supply voltages were 229 V (AC) and 104.9 V (DC), with no significant grounding anomalies, while visual inspection revealed no major equipment damage. The Algojo Feeder was therefore considered operationally reliable. However, HIRARC analysis identified latent hazards associated with equipment aging and workplace conditions. Risk control measures, including routine maintenance, safe work procedures, and consistent use of personal protective equipment (PPE), are recommended to maintain operational safety and reliability.
Edukasi Sistem Grounding sebagai Upaya Peningkatan Keselamatan Listrik dan Mitigasi Risiko Sambaran Petir Pada Kelompok Lansia Erfiana Wahyuningsih; Ganjar Febriyani Pratiwi; Belinda Ayuningtyas; Dihan Muhammad; Anrie Suryaningrat
Jurnal Penelitian dan Pengabdian Masyarakat Vol. 4 No. 3 (2026): August 2026
Publisher : Yayasan Pondok Pesantren Sunan Bonang Tuban

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61231/07mj6858

Abstract

This community service program aimed to improve electrical safety literacy among older adults through education on lightning risk and household grounding systems. The program used a participatory educational method consisting of partner needs identification, preparation of learning materials and instruments, pre-test, visual education, grounding system explanation, interactive discussion, post-test, and follow-up reflection. The materials covered misconceptions about smartphones and lightning, the function of grounding, household electrical safety, circuit breakers, and safe actions during thunderstorms. Evaluation was conducted using five indicators. The results showed improvements across all indicators: understanding of lightning misconceptions increased from 40% to 90%, grounding function from 35% to 88%, electrical safety from 50% to 92%, actions during lightning from 45% to 85%, and household installation understanding from 30% to 80%. The average increase reached 47%. These results indicate that simple, visual, and contextual education can improve older adults' understanding of grounding and lightning safety. The program supports community-based electrical safety literacy and encourages families to check household electrical installations with qualified technicians.