Claim Missing Document
Check
Articles

Found 2 Documents
Search

PERENCANAAN DESAIN ELECTRICAL SUBMERSIBLE PUMP (ESP) UNTUK MENINGKATKAN LAJU ALIR PRODUKSI PADA SUMUR “L-18” LAPANGAN “Z” BERDASARKAN KEMAMPUAN RESERVOIR Martinus Leo Andani; Risna Risna; Charles Pangaribuan; Amiruddin Amiruddin; Rohima Sera Afifah
PETROGAS: Journal of Energy and Technology Vol 5, No 2 (2023): October
Publisher : Sekolah Tinggi Teknologi MIGAS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58267/petrogas.v5i2.155

Abstract

Pada sumur “L-18” tekanan reservoir mengalami penurunan yang mengakibatkan laju produksi juga menurun, oleh karena itu dibutuhkan bantuan artificial lift jenis Electrical Submersible Pump (ESP) untuk mengoptimalkan laju alir produksi. Metode penelitian yang digunakan dalam tugas akhir ini yaitu dengan melakukan perencanaan desain. Hasil  perencanaan  desain   pompa    didapatkan pilihan  pompa  jenis  REDA  GN3200-60Hz  dengan  jumlah  stage  yang terpasang  sebesar 162.34 stage BHP motor sebesar 227.3 HP serta efisiensi pompa sebesar 62%, lalu  dipilih  jenis  motor  456  series  motor  dengan spesifikasi 60 iHz, 240 HP, 1993 V dan 78.6 A.
ANALISIS PENANGGULANGAN MASALAH SHALE PADA TRAYEK 8 ½" MENGGUNAKAN KCL - POLYMER POLYAMINE PADA SUMUR MKLS Mukhlis Farhan Rivani; Nijusiho Manik; Amiruddin Amiruddin; Esterina Natalia Paindan
PETROGAS: Journal of Energy and Technology Vol 8, No 1 (2026): MARCH
Publisher : Sekolah Tinggi Teknologi MIGAS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58267/petrogas.v8i1.209

Abstract

Shale formations in the 8 ½” section of MKLS Well in East Kalimantan present drilling challenges due to their reactive nature at high temperatures up to 250°F. The interaction between water-based mud and clay minerals can cause swelling, sloughing, and bit balling, which increase Non-Productive Time (NPT) and operational risks. This study aims to evaluate the effectiveness of a High Performance Water-Based Mud (HPWBM) system based on KCl–Polymer Polyamine in mitigating these risks. Testing included mud property evaluation, Linear Swelling Meter (LSM), Erosion Test, and Accretion Test using shale cuttings from MKLS Well. Results show a mud density of 1.36 g/cc, plastic viscosity of 15 cP, yield point of 25 lb/100 ft², filtrate loss of 4.8 mL/30 minutes, and pH of 9.40. Swelling of 3.5% (72 hours), erosion of 2.6%, and accretion of 1.45% indicate good inhibition, reducing wellbore instability, shale sloughing, tight hole, pack-off, and bit balling.