Claim Missing Document
Check
Articles

Found 2 Documents
Search

Analisis Kualitas Daya Beban 1-Fasa Non-Linear Pada Computer Assisted Test CPNS Gumilang, Binar Surya Gumilang; Masramdhani Saputra; Asfari Hariz Santoso; Saddani Djulihenanto
Elposys: Jurnal Sistem Kelistrikan Vol. 10 No. 3 (2023): ELPOSYS vol. 10 no. 3 (2023)
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/elposys.v10i3.4443

Abstract

Along with technological advances in the digital era like today, which is growing faster, it has an impact on many fields. One field that has used a lot of technological developments is the CPNS Test which is based on the CAT (Computer Assisted Test) and uses many a lot of laptop/computer devices to support the implementation of the test. The many uses of computers, especially during the recruitment test, influence the quality of electrical power due to the typical character of the PC/laptop load, which is a non-linear single-phase load which results in neutral currents or currents containing harmonics. This is because the load on the pc/laptop has electronic components such as semiconductors where there is a switching process that creates an impure sinusoidal wave that causes harmonics. In the case study, the implementation of the CPNS CAT with the use of PC/laptop devices will certainly cause a fairly high THD and affect the electric current/power source. The thing that needs to be considered with a high THD and the supply of electricity from the generator is the effect on the performance of the generator and the influence of the generator’s lifetime. Briefly, the loading of the data is to reduce the derating generator set by 6,717 kVa so that the safe loading is 23.28 kVa with a maximum capacity of 30 kVa generator. Synchronous generator loading is recommended at 81% of its nominal value with a current THD of 50%.
PENERAPAN SISTEM ELECTRIC SUBMERSIBLE PUMP (ESP) UNTUK BUDIDAYA BETTA SPLENDENS SISTEM RESIRKULASI AKUAKULTUR (RAS) Slamet Nurhadi; Masramdhani Saputra; Binar Surya Gumilang; Divac Nabiel Akbar; Saddani Djulihenanto; Galuh Prawestri Citra Handani; Hanifiyah Fidya Darna Amaral
JURNAL PENGABDIAN MANDIRI Vol. 2 No. 11: Nopember 2023
Publisher : Bajang Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Budidaya Betta Splendens memerlukan sirkulasi air yang berkelanjutan, terutama selama masa pertumbuhan ikan dari usia dua minggu hingga enam bulan ketika siap panen. Proses yang dinamakan Resirkulasi Akuakultur (RAS) ini memerlukan pasokan air segar secara teratur. Hal yang menjadi salah satu permasalahan yang dihadapi oleh kelompok ternak Betta Splendens di desa Sumberejo, Donomulyo, Kabupaten Malang. Sumber air yang digunakan untuk budidaya memiliki kedalaman yang sulit dijangkau menggunakan pompa gantung. Dalam kegiatan pengabdian ini penulis akan menerapkan sistem Electric Submersible Pump (ESP) untuk memompakan air dari sumur bor dengan kedalaman 15m. ESP memiliki sistem pompa yang tercelup ke dalam sumber air dan mampu menjangkau kedalaman tersebut. Adanya ESP membuat suplai air dari dalam sumur menuju kolam ataupun bak pembesaran Betta Splendens menjadi lancar dan tentunya akan lebih hemat dan efisien dalam pemanfaatan energi listrik.