Claim Missing Document
Check
Articles

Found 14 Documents
Search

Analysis of the effect of mechanical bending on the optical power of Bragg grating optical fibers in thermal measurements Wardah Azizah Matondang; Saktioto Saktioto
Science, Technology, and Communication Journal Vol. 7 No. 1 (2026): SINTECHCOM Journal (October 2026)
Publisher : Lembaga Studi Pendidikan dan Rekayasa Alam Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59190/stc.v7i1.353

Abstract

Bending of optical fibers is employed as a control parameter to evaluate the thermo-mechanical sensitivity and response of fiber Bragg grating (FBG) sensors in temperature measurements on curved structures. A uniform FBG is operated at two wavelengths, 1310 nm and 1550 nm, with bending angles from 0° to 60° and exposure to hot water vapor within a temperature range of 35°C – 49°C. The output power is measured using an optical power meter (OPM), and the Bragg wavelength shift is obtained from the transmission response. At 1550 nm, the transmitted power decreases from -25.83 dBm (0°) to -25.97 dBm (60°), accompanied by increased Bragg wavelength shifts at larger angles and higher temperatures. In contrast, at 1310 nm, the power variation is smaller (-30.57 dBm to -30.71 dBm), and Bragg wavelength remains almost unchanged at lower temperatures, with oscillations becoming noticeable only at larger bending angles. The 0° – 20° range exhibits the most stable response, whereas the 40°– 60° range at 1550 nm demonstrates the highest sensitivity to temperature variations. Overall, operation at 1550 nm is more responsive to thermomechanical effects, while 1310 nm exhibits greater stability against fiber bending.
Dual parameter calibration of fiber Bragg grating system for simultaneous measurement Rahma Dini; Saktioto Saktioto
Science, Technology, and Communication Journal Vol. 7 No. 1 (2026): SINTECHCOM Journal (October 2026)
Publisher : Lembaga Studi Pendidikan dan Rekayasa Alam Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59190/stc.v7i1.362

Abstract

This paper presents a numerical study of a dual-parameter fiber Bragg grating (FBG) sensing system for simultaneous measurement of temperature and strain with effective cross-sensitivity mitigation. The proposed system employs two FBGs operating at distinct Bragg wavelengths of 1550 nm and 1555 nm and subjected to different mechanical boundary conditions. One FBG is mounted in a loose-tube configuration to provide temperature-only sensitivity, while the second FBG is bonded to an elastic substrate, enabling simultaneous sensitivity to temperature and strain. Grating structures are designed using OptiGrating, and the optical interrogation system is modeled in OptiSystem. Calibration procedures, sensitivity matrix formulation, and decompensation algorithms are implemented numerically in MATLAB. Temperature calibration is performed over a range of 20°C – 80°C, while strain calibration is conducted from 0 to 2000 microstrain. The simulation results demonstrate highly linear responses, yielding sensitivity coefficients of 10.209 pm/°C for temperature and 1.2020 pm/ microstrain for strain, with coefficients of determination exceeding 0.997. The proposed decompensation algorithm successfully suppresses temperature-induced strain errors, reducing uncompensated crosssensitivity from 229.43 microstrain to numerically negligible levels under ideal simulation conditions. These results indicate that the proposed dual-parameter FBG sensing system offers high accuracy, stability, and immunity to electromagnetic interference, making it suitable for high-precision structural and industrial monitoring applications.
Apodization profiles of fiber Bragg grating spectra in temperature sensor applications Septia Putri Ayu; Saktioto Saktioto; Rakhmawati Farma; Rahmondia Nanda Setiadi
Science, Technology, and Communication Journal Vol. 7 No. 1 (2026): SINTECHCOM Journal (October 2026)
Publisher : Lembaga Studi Pendidikan dan Rekayasa Alam Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59190/stc.v7i1.383

Abstract

The presence of side lobes in the FBG reflection spectrum is a critical challenge that can reduce measurement accuracy in optical sensor applications, necessitating a systematic evaluation of apodization techniques as a mitigation strategy. This study investigated the comparative effects of three apodization profiles, namely uniform, Gaussian, and tanh hyperbolic, on the spectral characteristics and performance of an sensors-based temperature sensor with a grating length of 10 mm, grating period of 0.535 µm, modulation index of 0.0001, and operating wavelength of 1550 nm, over a temperature range of 20°C to 100°C. The results showed that all three profiles produced an identical thermal sensitivity of 13.725 pm/°C with a deviation of 3.23% from the theoretical value of 14.183 pm/°C. The Gaussian profile demonstrated the most superior side lobe suppression with an average side lobe level (SLL) of -45.51 dB, exceeding the minimum standard of -20 dB by more than 25 dB, far surpassing the uniform (-16.90 dB) and tanh (-18.17 dB) profiles. These findings establish the Gaussian apodization profile as the most optimal configuration, delivering the highest spectral quality without compromising thermal sensitivity.
Simulation and analysis of fiber Bragg grating for pulse strain monitoring using uniform and Gaussian apodization Amiroh Hasanah Yellis; Siti Fatimah; Saktioto Saktioto; Tengku Emrinaldi; Erwin Erwin; Defrianto Defrianto; José J Peña; Rina Amelia; Budi Astuti; Sofia Anita; Syamsudhuha Syamsudhuha; Dedi Irawan
Science, Technology, and Communication Journal Vol. 7 No. 1 (2026): SINTECHCOM Journal (October 2026)
Publisher : Lembaga Studi Pendidikan dan Rekayasa Alam Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59190/stc.v7i1.389

Abstract

Fiber Bragg grating (FBG) is a passive optical sensor that detects strain through Bragg wavelength shifts. This study designed and simulated an FBG-based pulse-strain monitoring system using uniform and Gaussian apodization at 1310 nm and 1550 nm. The system was designed using OptiGrating 4.2.2.69 and OptiSystem 11.1.0.53 with a single circuit comprising four parallel FBGs. Optical fiber parameters included a core diameter of 2 microstrain, a cladding diameter of 8 microstrain, core refractive indices of 1.4600 and 1.4605, and a grating length of 0.01 m. OptiGrating simulations showed that Gaussian apodization produced a cleaner reflection spectrum with lower sidelobes (around -60 dB) than uniform apodization, which exhibited higher, broader sidelobes (around -40 dB). OptiSystem analysis using an optical spectrum analyzer (OSA) at 1310 nm showed initial and final powers of 24.920 dBm and 24.934 dBm for Gaussian apodization, and 25.000 dBm and 24.997 dBm for uniform apodization. At 1550 nm, the corresponding values were 24.725 and 24.780 dBm for Gaussian, and 24.998 dBm and 24.992 dBm for uniform apodization. Strain calculations using the Bragg wavelength shift equation yielded sensitivities of approximately 1.21 pm/microstrain at 1550 nm and 1.02 pm/microstrain at 1310 nm for both profiles, consistent with theoretical FBG sensitivity. Optical power meter (OPM) measurements supported the OSA results, while oscilloscope analysis showed stable signals for both profiles, with uniform apodization displaying slightly higher and more consistent amplitude. Uniform apodization excels in reflectance and amplitude stability, while Gaussian apodization provides better spectral quality with lower sidelobes. The system targets the normal physiological pulse-strain range (10 – 50 microstrain). Apodization selection therefore depends on the strain-sensing application's priorities.