Claim Missing Document
Check
Articles

Found 2 Documents
Search

The Effect of Heat Flux on the Frequency of Bubble Appearance in a Boiling Pool Muhammad Hasan; Supriyadi; Larasati Rizky Putri; Sofia Debi Puspa; Sentot Novianto
Jurnal Asiimetrik: Jurnal Ilmiah Rekayasa dan Inovasi Volume 6 Nomor 1 Tahun 2024
Publisher : Fakultas Teknik Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/asiimetrik.v6i1.4812

Abstract

This research was conducted to determine the effect of heat flux on the frequency of bubbles appearing in boiling ponds. All fluid movement in pool boiling is caused by natural convection currents. The boiling pool consists of four areas of the pool boiling regime. The division of the four areas is based on the value of the heat flux and the difference between the surface temperature of the heater and the fluid. Using a two-phase heat transfer unit (H654 P.A. Hilton machine), The results showed that the power used greatly influences the boiling process, and besides that, the volume of water used also affects the duration of the boiling process. Based on tests using various power levels of 75 W, 110 W, 168 W, 237.5 W, and 290 W. The occurrence of bubbles will be faster and more numerous when using a lower volume of water and greater power. The heat transfer will be greater if a bubble appears, where latent heat plays a very important role. With mathematical analysis, an increase of 1 bubble per minute occurs for every increase in heat flux of 1.3 W/m2.
Study Characteristic Thermal Electric Generator (TEG) Type SP1848 27145 SA Sofia Debi Puspa; I Putu Budi Dharma; Sentot Novianto; Supriyadi; M. Alfian Gibran
Jurnal Asiimetrik: Jurnal Ilmiah Rekayasa dan Inovasi Volume 6 Nomor 1 Tahun 2024
Publisher : Fakultas Teknik Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/asiimetrik.v6i1.5561

Abstract

The TEG component, which operates on the Seebeck principle like a thermocouple, is widely used in the market, with TEG SP1848 27145 SA being one of the most common types. However, experiments must be conducted to determine its Seebeck coefficient, voltage, and power output when used with different heat and cold sources. This research aims to observe how the Seebeck coefficient, voltage, and power output of TEG SP1848 27145 SA change with variations in system temperature. To experiment, TEG SP1848 27145 SA is tested with a heater, and water flow rates are varied for cooling. Furthermore, the correlation between output voltage and ΔT has been determined through statistical analysis. The experiment results showed that the voltage output ranged from 0.54–1.03 V at a heater temperature of 86°C and an ΔT system value of 70.5-75°C. The Seebeck value was between 1,551.7-2,998.5 µV, and the power output was 43.5-67.7 mW. Additionally, the statistical analysis found a significant correlation between the temperature variable and output voltage variable, with an adjusted r square value of 89.2% for zero water flow rate and increasing to 95.8% for maximum water flow rate.