Search

PENERAPAN SISTEM PENYIRAMAN CERDAS BERBASIS TENAGA SURYA PADA PERKEBUNAN TERONG DI DESA TINGGAR Akmal Aziz; Muhammad Dicky Saputra; Andi Purwanto; Apipah Apipah; Rovino Alghafar; Dafairro Abbil Gunawan; Ardian Nurarifin; Aldi Fadilla Ramadhan; Muhamad Taufiq Hidayatullah Syari; Zulfa Akbar Al Fatah; Siswo Wardoyo
Community Development Journal : Jurnal Pengabdian Masyarakat Vol. 7 No. 3 (2026): Vol. 7 No. 3 (2026)
Publisher : Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/cdj.v7i3.59400

Abstract

Kegiatan pengabdian kepada masyarakat ini bertujuan untuk menerapkan sistem penyiraman otomatis berbasis energi surya pada perkebunan terong di Desa Tinggar, Kecamatan Curug, Kota Serang. Permasalahan utama yang dihadapi petani adalah proses penyiraman masih dilakukan secara manual sehingga kurang efisien dalam penggunaan udara dan tenaga kerja. Metode pelaksanaan kegiatan ini terdiri atas tiga tahapan utama, yaitu persiapan, pelaksanaan kegiatan, dan evaluasi. Hasil evaluasi menunjukkan adanya peningkatan pemahaman kelompok tani, di mana sebelum kegiatan ( pre-test ) sebanyak 80% peserta berada pada kategori sedang dan 20% pada kategori tinggi. Setelah pelaksanaan sosialisasi dan pelatihan, seluruh peserta (100%) berada pada kategori pemahaman tinggi. Dengan demikian, implementasi sistem irigasi otomatis berbasis energi surya berjalan dengan baik dan efektif dalam meningkatkan efisiensi budidaya tanaman terong serta pemahaman petani terhadap teknologi pertanian modern berbasis energi terbarukan.
Pengujian Kinerja Jaringan Topologi STAR dengan Switching: Studi Simulasi Menggunakan Cisco Packet Tracer Ardian Nurarifin; Rachmatul Hidayathika; Fiana Fiana; Rafika Desfiana; Didik Aribowo
Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika Vol. 2 No. 3 (2024): Mei : Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/jupiter.v2i3.315

Abstract

In the present day, many have used communication tools to share data as text, video, images, or sound and the like. There is a speed of data transmission depending on the delivery method, if there is a system error then the data is likely not to be sent, therefore there are various types of data managers so that there are no obstacles or errors during the data transmission process. The star topology was chosen for its advantages in network management, trouble shooting and providing reliable and easy-to-organize connectivity. The main focus is to evaluate the efficacy and effeciency of the star topology in handling different amounts of data traffic using performance characteristics including packet loss, jitter, delay, and throughput. And the use of switching in the star topology can provide optimal and stable performance under high traffic load can provide reliability and efficiency in data traffic management.
Studi Medan Elektromagnetik pada Pembangkit Listrik Tenaga Surya Yuninda Triyatne; Ardian Nurarifin; Sonata Mahardika; Umar Hamzah; Diyajeng Luluk Karlina
Jupiter: Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika Vol. 2 No. 6 (2024): November : Publikasi Ilmu Keteknikan Industri, Teknik Elektro dan Informatika
Publisher : Asosiasi Riset Ilmu Teknik Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.61132/jupiter.v2i6.609

Abstract

This research investigates the electromagnetic field (EMF) characteristics generated by solar power plants, focusing on their potential environmental and health impacts. The study employs a dual methodology combining direct measurements using gaussmeters and computer simulations using COMSOL software to map electromagnetic fields around solar power installation components. Measurements were taken under two conditions: during solar power plant operation and non-operation, to establish comparative baseline data. The research found significant variations in electromagnetic field intensity based on operational status and distance from components, particularly near inverters and cable networks. Results indicate that EMF levels are higher during operation, with field strength decreasing exponentially with distance from the source. These findings contribute to understanding EMF distribution patterns in solar installations and provide valuable insights for implementing appropriate mitigation strategies to ensure safe operation within established exposure standards.